Transportation Engineering / Highway Engineering
Tie bars are not designed as a load transfer device. As two slabs are firmly held together, load is transferred to the adjacent slab through aggregate interlock.
Tie bar free body: friction force on the half-slab section (1 m length) balanced against the steel tensile capacity σst×Ast across the tie bars.
σst = 230 N/mm² (for Fe415), γc = 2400 kg/m³ (≈ 24 kN/m³).
The length of the tie bar is decided on the basis of development length, and length is taken as 2×ld.
Dowel bar at a transverse (expansion) joint: bonded/fixed on one side (solid), free/greased on the other (dashed) so the joint can still open by δ.
Dowel bars act as load transfer devices across the transverse joint, and they keep the two slabs at the same height. They are mild steel round bars, bonded on one side and free on the other side.
Normally the dia is used as 25 to 40 mm, and the length is 400 to 500 mm.
The stresses in the dowel bars are:
The stresses in the dowel bars are calculated using Bradbury's analysis. Load transfer capacity of a single dowel bar is given by:
d = dia. of bar, σs = permissible shear stress in steel. Ps = load transfer capacity of single dowel bar in shear.
Pb = load transfer capacity of single dowel bar in bending (kg). d = dia of bar (cm). σb = permissible bending stress in steel (kg/cm²). L = length (cm). δ = gap in the joint (cm).
Pbr in kg; σbr in kg/cm²; all lengths in cm.
Step 1 — The embedded length of dowel bar is decided by equating bending and bearing stress. At this stage, we assume the joint width (δ) and the dowel diameter (d).