Transportation Engineering / Highway Engineering
Dowel group along the joint (left) and the linear load-distribution wedge (right): full capacity (1) at the loaded dowel, decreasing linearly to zero at 1.8 l.
Taking Px = min{Ps, Pb, Pbr} (the governing single-dowel capacity), the group check to find spacing s becomes:
NoteNone of the resisting terms in the series should be negative — stop adding terms once (1.8l − ns) would go below zero.
L = embedded length of dowel bar, δ = joint thickness.
Design wheel load = 51 kN. Design load transfer capacity through dowel = 40%. Slab thickness = 28 cm. Joint thickness = 2 cm. Permissible bending stress in dowel bar = 140 MN/m². Permissible shearing stress in dowel bar = 100 MPa. Permissible bearing stress = 10 MPa. Modulus of subgrade reaction = 80 MN/m³ (= 8 kg/cm³).
l = 91.52 cm
L is calculated by bending and bearing stress. Assume d = 3 cm (round bar), δ = 2 cm.
L = 49.67 cm ⇒ length of dowel bar = 49.6 + 2 = 51.6 cm, dia of dowel bar = 3 cm.
Pbr = 1125 kg (from the same equality used to derive L, Pb = Pbr by construction).
min{Ps, Pb, Pbr} = 1125 kg. 1.8×l = 1.8×91.52 = 164.74 cm.
Summing the 4-term series (dowel spacings s, 2s, 3s within 1.8l):
s ≤ 60.03 cm ⇒ provide dowels at 50 cm c/c.
Finally, we can check that for the adopted spacing, load resistance in 1.8l length is greater than 0.4P.
Cement concrete pavement has thickness of 24 cm and has two lanes of total width 7.2 m with longitudinal joint. Design the dimensions (spacing of bars). Unit weight of concrete = 2400 kg/m³. Coefficient of friction = 1.5. τbd (bond stress) = 24.6 kg/cm². Permissible stress in steel = 1400 kg/cm².
Adopt 10 mm dia bar (area = 78.54 mm² each):
Provide tie bars at spacing of 350 mm c/c.
L = 28.45 cm ⇒ provide 30 cm length tie bar.
The failure criteria for rigid pavement is fatigue cracking and pumping. IRC code gives design steps for only fatigue cracking.