Transportation Engineering / Highway Engineering

TRANS-02E Dowel Group Design, Worked Examples, Failure Criteria

Converted from handwritten notes — TRANSPORT 02.pdf, pages 21–28

Doc No.TRANS-02E
StatusDraft — Awaiting Review
Converted09-08-2026
Approved—

Dowel bar group design steps

  1. Calculate Ps, Pb, and Pbr.
  2. Load transfer capacity of dowel bar is assumed to be 40% of wheel load (P).
  3. The distance on either side of the load position, up to which the group of dowel bars are effective in load transfer, is taken as 1.8 l, where l = radius of relative stiffness.
  4. The load capacity factor required is calculated as the max of:
    maxm0.4PPs0.4PPb0.4PPbr
  5. The capacity of the dowel directly under the wheel load is assumed to be 1 (full share), and is assumed to be zero at a distance of 1.8 l from the wheel.
IsIs 1.8 l 1 0 (1.8l−s)/1.8l (1.8l−2s)/1.8l

Dowel group along the joint (left) and the linear load-distribution wedge (right): full capacity (1) at the loaded dowel, decreasing linearly to zero at 1.8 l.

Series sum up to 1.8 l — load capacity factor 1+1.8l−s1.8l+1.8l−2s1.8l+… up to 1.8l>maxm0.4PPs,0.4PPb,0.4PPbr

Taking Px = min{Ps, Pb, Pbr} (the governing single-dowel capacity), the group check to find spacing s becomes:

Spacing check Px+1.8l−s1.8lPx+1.8l−2s1.8lPx+…≥0.4P

NoteNone of the resisting terms in the series should be negative — stop adding terms once (1.8l − ns) would go below zero.

Actual (total) length of dowel bar Actual length=L+δ

L = embedded length of dowel bar, δ = joint thickness.

Worked example — dowel bar system design

Design data

Design wheel load = 51 kN. Design load transfer capacity through dowel = 40%. Slab thickness = 28 cm. Joint thickness = 2 cm. Permissible bending stress in dowel bar = 140 MN/m². Permissible shearing stress in dowel bar = 100 MPa. Permissible bearing stress = 10 MPa. Modulus of subgrade reaction = 80 MN/m³ (= 8 kg/cm³).

Radius of relative stiffness l=3×105 kg/cm²×28³ cm³12×8 kg/cm³×(1−0.152)1/4

l = 91.52 cm

L is calculated by bending and bearing stress. Assume d = 3 cm (round bar), δ = 2 cm.

L=5×3140×(L+1.5×2)10×(L+8.8×2)

L = 49.67 cm ⇒ length of dowel bar = 49.6 + 2 = 51.6 cm, dia of dowel bar = 3 cm.

Ps=π4×32×1000=7068 kg Pb=2×33×140049.6+8.8×2=1125 kg

Pbr = 1125 kg (from the same equality used to derive L, Pb = Pbr by construction).

π/4×9×1000 = 7068.6; 2×27×1400/67.2 = 1125 — both match source.

min{Ps, Pb, Pbr} = 1125 kg. 1.8×l = 1.8×91.52 = 164.74 cm.

0.4P=0.4×5.1×103=2040 kg

Summing the 4-term series (dowel spacings s, 2s, 3s within 1.8l):

11254−6s164.74≥2040

s ≤ 60.03 cm ⇒ provide dowels at 50 cm c/c.

Finally, we can check that for the adopted spacing, load resistance in 1.8l length is greater than 0.4P.

Worked example — tie bar spacing

Design data

Cement concrete pavement has thickness of 24 cm and has two lanes of total width 7.2 m with longitudinal joint. Design the dimensions (spacing of bars). Unit weight of concrete = 2400 kg/m³. Coefficient of friction = 1.5. τbd (bond stress) = 24.6 kg/cm². Permissible stress in steel = 1400 kg/cm².

Steel area required, per metre length of joint, B = 3.6 m Ast=3600 mm×240 mm×2400 kg/m³×1.5×1000 mm1400 kg/cm² (= 140 N/mm²)=222.17 mm²
3.6×0.24×2400×1.5 = 3110.4 kgf; /1400 kgf/cm² = 2.222×10⁻⁴ m² = 222.2 mm² — matches source.

Adopt 10 mm dia bar (area = 78.54 mm² each):

Spacing=1000×π4×102222.17=353.33 mm

Provide tie bars at spacing of 350 mm c/c.

L=2×ld=2×1400 kg/cm²×1 cm4×24.6 kg/cm²

L = 28.45 cm ⇒ provide 30 cm length tie bar.

1400×1/(4×24.6) = 14.23 cm, ×2 = 28.46 cm — matches source.

Failure criteria for rigid pavement

The failure criteria for rigid pavement is fatigue cracking and pumping. IRC code gives design steps for only fatigue cracking.