Structural Steel Design / Beam Design / Part 2 of 2

Beam Design — WSM & LSM

Converted from handwritten notes — Steel Structure 3.pdf, pages 19–52

Doc No.SS-03-02
StatusDraft — Awaiting Review
Converted17-08-2026
Approved—

Design for Beam (WSM)

shear connector concrete slab M diagram (elastic)

Composite beam with shear connectors bonding the steel section to a concrete slab (left), and an elastic bending-stress triangle through the depth (right).

main beam cross beam

Cross beams framed into main beams, restraining the compression flange laterally — a grillage-style floor arrangement.

Laterally supported vs. laterally unsupported beam

Beam can be laterally supported or laterally unsupported. In case of a laterally supported beam — i.e. the beam in which there is no chance of lateral buckling — σbt = σbc.

Section typeσbt = σbc
Flanged section0.66 fy or 165 MPa
Solid section0.75 fy

For a laterally unsupported beam, σbc < σbt (compression capacity is reduced by the risk of lateral-torsional buckling).

Note — what counts as lateral restraint Lateral restraint to the compression flange can be assumed to exist if the restraint is capable of resisting a lateral force not less than 2.5% of the maximum force in the compression flange of the beam.

Design Criteria for Laterally Supported Beam (WSM)

web crippling web buckling local buckling of flange plate (b/t > 16)

Secondary-criteria failure modes: web crippling (local crushing under a point load), web buckling (the web acting as a compression member), and local buckling of an over-slender flange outstand.

  1. Design for bending — primary criteria
  2. Check for shear — primary criteria
  3. Check for deflection — primary criteria
  4. Web crippling — secondary criteria
  5. Web buckling — secondary criteria
  6. Local buckling of flange/web plates (in the form of waves/wrinkles) — secondary criteria
In case of rolled sections only, a check for secondary criteria is not required. However, in case of built-up sections, a check for secondary criteria is mandatory.

Design for Bending

Mmax=M0 Zreq≥M0σbt
Ap d y y x x

Adding a cover plate of area Ap at the compression flange (deflection is predominant in the deeper cross-section), raising Z beyond what the rolled section alone provides.

I=Irolled xx+2Ap×(d2)2 Id/2=Irolled (xx)d/2+Apd≈Zrequired=(Zrolled+Apd)
Ap=Zreq−Zrolledd
t b NA shifts up 100 in area

Cover plate of width b, thickness t placed at the flange — the neutral axis shifts slightly toward it as area increases.

Loss of area at bolt holes The Ap value so obtained has to be increased to account for loss in area due to holes. We will provide area Ap, double the Ap value obtained using Ap = (Zreq − Zrolled)/d.

Check for bending

M0×(d2+t)Ig≤σbt Ig=Ixx one+{bt³12+bt(d2+t)2}×2

Since bolt holes reduce the flange area only over discrete lengths, a further check compares the ratio of gross to net flange area against the ratio of allowed to actual stress:

M0(d2+t)Ig×gross area of tension flangenet area of tension flange≤σbt

Gross area = flange plate area + (width of I-section flange × tf).

T t b B

Rivets/bolts of diameter T through a cover plate of width b, thickness t, atop a flange of width B.

Agross=BT+bt−(t+T)d×2
rivets provided as staggering Top Bottom

Staggered rivet pattern in the cover plate.

NOTE: at least one cover plate, if provided, should be continuous to the end.

Theoretical cutoff point (TCP)

MI1 MI2 MI1 TCP → theoretical cutoff point

MI2 = MOR for I-section + 2 plates; MI1 = MOR for I-section + 1 plate. The TCP is where the parabolic bending-moment diagram crosses MI1.

The theoretical cutoff point (TCP) is the point where the moment of resistance due to the continuing section is equal to the applied bending moment.

x ℓp M M

Fixed-fixed beam under UDL — cover plate extends over length (ℓ − 2x); the plate length ℓp = ℓ − 2x.

M=(wℓ2⋅x−wx22)=σBp[Z due to I-section + 1 plate]

Find x. Then ℓp = ℓ − 2x.

Check for Secondary Criteria

1. Local buckling of flange and web plates

b' b t root of fillet g dw h₂ h₂

g (gauge distance) is given in the steel table; b, b', h₂ and dw are the outstand/web dimensions checked below.

Limit (WSM)Limit (LSM)
b/t ≤ 16b/t ≤ 15.7ε
b'/t ≤ 50b'/t ≤ 42ε

dw/tw ≤ 50 for the web plate.

2. Check for web crippling

P h₂ root of fillet

Web crippling — local crushing of the web where a point load or reaction bears against it.

Web crippling takes place at the section having minimum area of web resisting the load. The 1st such section is encountered at the root of fillet. Hence, for point loading in the span or for support reactions, bearing stress is calculated at the root-of-fillet location, and it should be less than the permissible bearing stress. Permissible bearing stress is taken as 0.75fy.

P a 30° ℓ 30° ℓ' R b

Dispersion at 30° from the point of load application (span, above) and from the support edge (below) down to the root of fillet, a distance (h₂ + t) away.

ℓ=a+2(h2+t)3 ℓ′=b+3(h2+t)

In span:

(P[a+2(h2+t)3]tw)≤0.75fy

bearing stress at root of fillet ≤ permissible bearing stress — check (A)

At support:

(R[b+(h2+t)3]tw)≤0.75fy

check (B)

If (A) and (B) are satisfied, the beam is safe in web crippling.

3. Check for web buckling

To check for safety against web buckling, the web is treated as a column having slenderness ratio:

λ=dw3tw

ℓeff = dw/2, rmin = tw/√12, dw = d − 2h₂.

σac=Merchant-Rankine(λ=dw3tw corresponding)

Area resisting compression = ℓ × tw = A.

σac×A≥P

for safety against web buckling.

Generally, if a beam is safe in web crippling, it will be safe in web buckling.

Worked Example — Beam Design with Cover Plates (WSM)

A simply supported beam of 6.75 m span is to support a UDL of 40 kN/m (inclusive of self-weight). Design the beam section using ISMB 300 or ISMB 400, which are available in the store. If required, a flange plate may be used. Support width may be taken as 300 mm.

σbc=σbt=0.66×250=165 MPa Mmax=wℓ28=227.82 kN·m Zrequired=227.82×106165=1.38×106 mm³=1380 cm³
ISMB 300ISMB 400 @ 61.6 kg/m
Z573.6 cm³1022.9 cm³
d300 mm400 mm
T12.4 mm16 mm
tw8.1 mm8.9 mm
h₂29.2 mm32.8 mm
g80 mm80 mm
B140 mm140 mm

Let us adopt ISMB 400. Zprovided = Zrolled = 1022.9 cm³. Additional Z will be provided through cover plates.

Ap=Zreq−Zrolledd=(1380.68−1022.9)×103 mm³400 mm
Ap=894 mm²
g (225−80)/2=72.5 = b B

Providing 225 × 8 mm plates at top and bottom — outstand each side = (225−80)/2 = 72.5 mm = b.

bt=72.58=9.06<16 OK — safe in local buckling of flange plate. gt=808=10<50 OK

Check for bending

MfmaxI=227.82×106 N·mm×208 mm1022.9×103×200+2⋅225×8312+225×8×2×2042
=133.7 N/mm²
gross area of tension flangenet area of tension flange=225×8+140×16225×8+140×16−19.5(16+8)×2=1.301

adopting 18 mm dia rivets.

MfmaxIgross×AgANA=133.69×1.301=173.93>165 not safe

Let's provide staggered rivets instead:

AgAn=225×8+140×16225×8+140×16−19.5×24=1.131 MfmaxI×AgAn=133.69×1.131=151.2 N/mm²<165 N/mm²
OK — safe in bending.

Check for shear

τmax=Vmax400×8.9 Vmax=wℓ2=40×6.752=135 kN
τmax=37.92 N/mm²<0.4fy (100 MPa) OK — safe in shear.

Check for deflection

Self-weight of the built-up section If we calculate the dead load of the beam, it will be DL of the I-section + DL of the plates.
ISMB 400 @ 61.6 kg/m, 2 plates=(2×1800×1000×10−9) m³×7850 kg/m³=28.26 kg/m DL=89.86×9.81 N/m=0.881 kN/m
Δmax=5384wℓ4EI=5384×40×(6750)42×105×[354.420×106]
Δmax=15.25 mm span325=6750325=20.77 mm

Δmax < span/325 — OK, safe in deflection.

Check for web crippling

ℓ=300+3×(h2+t) Bearing area=[300+3(32.8+8)]×8.9=3298.94 mm²
Bearing stress=Vmax3298.94=40.92 N/mm²<0.75fy (187.5 MPa) OK — safe in web crippling.

Check for web buckling

λ=dw3tw=(400−2×32.8)38.9=65.07
σac=0.6fcc⋅fy[fcc1.4+fy1.4]1/1.4 fcc=π2E65.082=466.08 N/mm²
σac=116.87 MPa
300+208=508 45° 300 208

45° dispersion from the 300 mm support width down to the far web edge, 208 mm below (half-depth minus flange), giving a resisting length of 508 mm.

Area resisting=508×8.9=4521.2 mm²
σac×area=528.42 kN>135 kN OK — safe in web buckling.

LSM (Design of Beam)

In our course we will consider laterally restrained beams only. For a laterally restrained beam, we have to consider two cases.

Low shear case (V<0.6Vd)

Vd is the fully plastic shear capacity of the section.

High shear case (V>0.6Vd)
M V → Md 0.6Vd Vd Mfd

Moment-shear interaction — moment capacity holds at Md up to V = 0.6Vd, then decreases toward Mfd as V approaches Vd.

d Av = d × tw Av = d × tw

Shear area Av = d × tw for a rolled I-section, taken as the full web depth × web thickness.

Vd=Av×fy3×γmo

For V < 0.6Vd, moment capacity of the section is independent of shear. However, for V > 0.6Vd, moment capacity will be affected by shear, and moment capacity decreases below that in the case of low shear. V → factored maximum shear force. For safety in shear, V < Vd.

Case 1 — low shear case (V ≤ 0.6Vd)

Md=βb⋅Zp(fyγmo)≤1.2fyγmo×Ze for SS beam ≤1.5(fyγmo)×Ze for cantilever beams
Additional checks The additional caps Md ≤ 1.2fy/γmo·Ze and Md ≤ 1.5fy/γmo·Ze, as the case may be, are done to prevent the onset of plasticity under unfactored dead, live and wind load.

Effect of bolt holes

The effect of bolt holes in the tension flange need not be considered if:

0.9fuAnγm1≥fyAgγmo (yielding governs)

If the above condition is not satisfied, we will take the area of the tension flange as the net area given by:

An=(fyγmo×Ag)×γm10.9fu

Case 2 — high shear case (V > 0.6Vd)

When V > 0.6Vd, design bending strength will be less than in the low shear case. The reduced moment capacity Mdv is given by:

For plastic and compact section:
Mdv=Md−β(Md−Mfd)≤1.2fyγmo×Ze

Md = design moment capacity for low shear case. Mfd = design capacity of c/s excluding the shear area.

β=[(2VVd)−1]2

V → factored shear force. Vd → design shear capacity under fully plastic condition.

For semi-compact section:
Mdv=Zefyγmo (=My)

Checks for Shear, Deflection & Web Buckling (LSM)

Check for shear

If maximum factored shear force is less than Vd, the section is safe in shear.

Vd=fy3×1γmo×Av

Av = web area.

Check for deflection

Calculation of maximum deflection is done at service load, and maximum deflection should be taken as (span/300) mm.

Web buckling strength (LSM)

P 45° 45° NA ℓ ℓ R

45° web-buckling dispersion from the point load down through the neutral axis to the support.

Web buckling strength is taken as fwb, where:

fwb=ℓ×tw×fcd

fcd is calculated by taking buckling class as 'c', and slenderness ratio is taken as λ = 2.5 dw/tw.

dw λ = (dw/2)/(tw/√12) λ = (dw√2)/(tw/√12) = √6 · dw/tw ≈ 2.5 dw/tw

Effective length for web-as-column: hinged-hinged web strip (top) vs. fixed-free at a free flange edge (bottom), giving the 2.5 dw/tw approximation.

λ=2.44dwtw≈2.5dwtw

For safety @ support: R ≤ fwb. For safety @ point load: P ≤ fwb.

NOTE:
(1) If d/tw < 67ε, and if it is the low shear case, the section will be safe in web buckling.
(2) If d/tw ≱ 67ε, but if it is the high shear case, we need to check for web buckling.
(3) If d/tw > 67ε, we will check for web buckling.

Web Crippling (LSM), Section Classification & Design Steps

P 2.5H:1V ℓ R R = radius of fillet T R

LSM web crippling dispersion at 2.5H:1V from the bearing length to the toe of the root fillet.

P<ℓ×tw×(fyγmo) for safety R≤ℓ×tw×(fyγmo) for safety

Design steps

  1. Find factored maximum shear force and factored maximum bending moment.
  2. Choose a trial section corresponding to M/(fy/γmo) = Zp.
Shape factor as a substitute for Zp The value of Zp for various sections is given in the IS code. In case Zp for the section is not known, we can take it as SF·Ze, where SF = shape factor for the section, which can be taken as (1.1–1.15).

Classify the section on the basis of b/tf and d/tw:

b/tfd/twClassification
9.4ε84εPlastic
10.5ε105εCompact
15.7ε127εSemi-compact

If the NA lies at mid-depth of the section, then (d/tw) is used directly (symmetrical section).

The trial section is checked for shear. If V < (fy/(√3γmo) × Av) = Vd, the section is safe in shear. Check whether it is the case of low shear or high shear: V < 0.6Vd → low shear; V > 0.6Vd → high shear.

NOTE: if d/tw < 67ε and V < 0.6Vd, the beam is safe in web buckling. Otherwise we will have to check for web buckling also.

Depending upon whether it is a low shear case or high shear case, moment capacity of the section will be calculated. If the factored maximum bending moment is less than the moment capacity, the section is safe in bending. Finally we will check for (1) deflection, (2) web buckling, (3) web crippling.

Cover plates in LSM If there is no single rolled section which can provide the necessary Zp, we will use cover plates and Ap calculated by Ap = (Zp,req − Zp,rolled)/d. If (0.9fu/γm1) × An,p > (fy/γmo) × Ag,p, we do not need to increase the value of Ap obtained using the above formula. In case Ap does not satisfy this, we will increase the Ap calculated.

Worked Example — Design Bending Strength of ISLB350 (Low Shear)

Determine the design bending strength of ISLB350, considering the beam to be laterally supported. Assume low shear case.

PropertyValue
d350 mm
tw7.4 mm
T11.4 mm
B165 mm
Ixx13158.3 cm⁴
Iyy619 cm⁴
Zp,xx851.11 cm³
Ze,xx751.99 cm³
btf=165/211.4=7.23<9.4ε ε=250fy=1 dtw=3507.4=47.29<84ε ⇒section is plastic
Md=βbfyγmo×Zp≤1.2fyγmo⋅Ze

βb = 1 for plastic & compact sections.

=1×2501.1×851.11×103 =193.43 kN·m≤1.2×2501.1×751.9=205.06 kN·m
Md=193.43 kN·m

Worked Example — 4m SS Beam, Fe410, ISLB200

A simply supported steel beam of effective span 4 m is laterally supported throughout. It carries UDL of 40 kN, inclusive of self-weight. Design appropriate section using Fe410 grade steel.

UDL=404=10 kN/m wu=1.5×10=15 kN/m Vu=15×42=30 kN Mu=15×428=30 kN·m
Zp required=M(fy/γmo)=30×106(250/1.1)=132 cm³

For ISLB 200: Zp = 184.34 cm³, Ze = 169.7 cm², shape factor 1.08.

PropertyValue
d200 mm
tw5.4 mm
tf7.3 mm
b (flange half-width)50 mm
Ixx1896.6 cm⁴
h₂17.15 mm

Section classification

dtw=2005.4=37.03<84ε btf=507.3=6.84<9.4ε ⇒section is plastic
Vd=fy3×Av=2503×1.1×5.4×200
Vd=141.71 kN

V = 30 kN < Vd → safe in shear. 0.6Vd = 85.02 kN, V < 0.6Vd ⇒ low shear case.

Since V < 0.6Vd and d/tw < 67ε, no need to check for web buckling.

Moment capacity

Md=βbZpfyγmo≤1.2fyγmo×Ze =1×2501.1×184.34×103
Md=41.89 kN·m≤1.2×2501.1×169.7=46.28 kN·m

Md = 41.89 kN·m > 30 kN·m — OK, safe in bending.

Check for deflection

Δmax=5384wℓ4EI=5384×10×(4000)42×105×1896.6×104
Δmax=9.82 mm
span325=4000325=13.333 mm

Δmax < span/325 — safe in deflection.

Check for web crippling

ℓ=300+17.15×2.5=342.87 mm

assumed support width = 300 mm; h₂ = 17.15 mm.

ℓ×tw×fyγmo=342.875×5.4×2501.1
=420.8 kN>30 kN Safe — safe in web crippling.

Worked Example — 6m Laterally Supported Beam, Fe410 (High Shear)

Design a laterally supported beam of effective span 6 m for the following data. Grade of steel = Fe410. Maximum BM = 150 kN·m. Maximum SF = 210 kN. Check for deflection (NA). The given BM and SF are factored values.

Zp required=M(fy/γmo)=150×106250/1.1=660 cm³

Let's choose ISLB 350: Zp = 851.11 cm³, Ze = 751.9 cm³, B = 165 mm, tf = 11.4 mm, tw = 7.4 mm, h₂ = 30.85 mm.

dtw=3507.4=47.29≤84ε and <67ε ⇒section is plastic btw=165/211.4=7.23<9.4ε
Vd=fy3×1γmo×Av=2503×11.1×350×7.4
Vd=339.85 kN

V = 210 kN < Vd → OK, safe in shear. 0.6Vd = 203.9 kN < V ⇒ high shear case.

Moment capacity (high shear)

Mdv=Md−β(Md−Mfd)≤1.2fyγmo⋅Ze β=(2×210339.8−1)2=0.055

βb = 1 for plastic section:

Md=1×fyγmo×Zp=1×2501.1×851.11×103
Md=193.43 kN·m

1.2 × (250/1.1) × 751.9 × 10³ = 205.06 kN·m, so Md = 193.4 kN·m < 205.6 kN·m.

Mfd (design capacity of c/s excluding the shear area, i.e. web):

Mfd=(Zp−twd24)fyγmo=(851.11×103−7.4×35024)2501.1
Mfd=141.92 kN·m
Mdv=193.4−0.055(193.4−141.92)
Mdv=190.56 kN·m<205.06 kN·m

Mdv > M — OK, safe in bending.

Check for web buckling

λ=2.5dwtw=2.5(350−2×30.85)7.4
λ=97.39 for buckling class 'c'
λfcd
90121
100107

Interpolating: fcd = 110.65 MPa.

300+175=475=ℓ 45° 300mm ← assume 350/2

45° dispersion from the 300 mm assumed support width across the half-depth of ISLB350, giving ℓ = 300 + 175 = 475 mm.

A=475×7.4=3515 mm² fcd×A=110.65×3515=388.93 kN>210 kN
OK — safe in web buckling.