Structural Steel Design / Column Bases / Part 1 of 2
The various types of column bases that are used are:
Slab base — a thick base plate under the column, direct-bearing on a concrete pedestal. Mostly used for purely axial loading.
Gusseted base — gusset plates and angle cleats transfer load into a wider base plate on a stepped pedestal. Adopted for axial loading combined with heavy moments.
Grillage foundation (plan below, elevation above) — stacked, orthogonal tiers of rolled-steel joists encased in concrete. Adopted in temporary construction and when a heavy load must be transferred at shallow depth.
In case of an axially loaded condition, a square plate may be adopted.
H-section column welded to a square base plate B × B, thickness t. α and β are the overhang distances beyond the flange/web on each side.
a = larger overhang
b = smaller overhang
as per IS code, for the axial loading condition.
Uniform bearing pressure w = P/B² acting upward on the underside of the base plate for the purely axial case.
| Section type | Permissible bearing stress |
|---|---|
| Flanged section | 0.67 fy |
| Solid section | 0.75 fy |
For the base plate under a uniform pressure w (N/mm²), a strip of unit width (1 mm) is analysed as a cantilever fixed along the flange/web edges, spanning the overhangs a and b:
Cantilever strips 1-1 (spanning a, moment M₁₁) and 2-2/3-3 (spanning b, moment M₂₂) around the H-section footprint.
The plate bends biaxially at once, so the true combined stress accounts for the Poisson effect between the two directions:
For safety:
(the code has taken μ = 0.25 for WSM)
Base plate under eccentric load: linearly-varying bearing pressure P/A ± My/I, from a peak of f₄ (P/A + My/I) down to f₁ (P/A − My/I), with intermediate values f₂, f₃ through the H-section footprint width.
The flange-web junction (near the highest-stress zone) is the critical location where M₁₁ and M₂₂ are checked.
Under non-uniform pressure, the cantilever strip moments are found from the average intensity over the tributary area, with the resultant located at its centroid:
With M = P·e, treating the base plate/pedestal as a rectangular section L × B under combined axial load and moment:
σc = permissible stress in concrete. Choose L, find B.
For no tension anywhere at the base, the minimum edge pressure must stay non-negative:
for no tension at base, with e = M/P.
σbs → 1.2fy/γmo. σc → 0.45fck (marked in the source as revised to 0.6fck — see note below).
Choose L & find B. For no tension at base: L > 6e.
Uniform 0.45fck limit (pure axial case) vs. the linearly-varying pressure diagram (axial + moment case), where the peak edge pressure f₁ is capped at 0.6fck.
Using the yield-line moments M₁₁ = wa²/2 and M₂₂ = wb²/2 with a > b, and μ = 0.3 in LSM:
(μ taken as 0.3 in LSM)
Column SC200 (I-section) is to support an axial compressive load of 700 kN and moment of 55 kNm. Design the column slab base assuming the bearing ends to be milled. Allowable bearing stress of concrete in footing is 3.75 MPa.
Also design the welded connection between the slab base and column. Thickness of column flange = 15 mm; take the strength of a 1 mm fillet weld per mm length to be 76 N. Permissible bending stress in plate is 175 N/mm². Take μ = 0.25.
Column SC200 — 200 mm × 200 mm I-section, flange thickness 15 mm.
Column-end milled and seated directly on the slab base; connection welds carry only the moment.
a = 200 mm (larger overhang direction), b = 180 mm (smaller overhang direction).
Linearly-varying bearing pressure across L = 600 mm, ranging from 0.446 MPa to 3.72 MPa, with 2.63 MPa at the column centreline (200 mm from the high-pressure edge).
Cantilever moments for a = 200 mm, taking the average pressure over the tributary triangle-trapezoid area (per 1 mm width):
These moments are for a 1 mm width strip.
Since the column end is milled, the weld is designed only to resist the force T (and equal compression C) arising from the moment, taken as a couple at the flange centres, 200 mm apart:
The weld will be designed only to resist force due to moment, because the column end is milled (direct load already transfers by bearing).
1 mm fillet weld of size s = 1 mm carries 0.7 × 1 × σsw = 76 N per mm length.
Largest weld size that can be provided at the flange (given flange t = 15 mm) is t − 1.5 = 13.5 mm; the minimum size corresponding to a 45 mm-thick base plate is 10 mm. We adopt size of weld = 13.5 mm.
But the available flange width is only 200 mm, so welds must also be provided on the inner side of the flange:
Solve the above problem using LSM. Take μ = 0.3, grade of base concrete M20, grade of steel in weld Fe410.
1050×10³/(600×B) with fck = 20 MPa, adopting L = 600 mm.
LSM bearing pressure diagram — 1.07 to 8.928 MPa across L = 600 mm, with 6.309 MPa at the column centreline; a = 200 mm, b = 75 mm.
fu = 410 N/mm², Mu/200 = 82.5×10&sup6;/200, γm1 = 1.25
Provide ℓ = 200 mm outer side + 45 mm inner side.
In case the length of the base is fixed and ℓ < 6e, tension will develop at the base.
Loss of contact over part of the base — final contact length shrinks to 3(L/2 − e), with peak compressive stress rising accordingly; the opposite side goes into tension, requiring holding-down bolts.
In this case we need to design the holding-down bolt also, because the bolt will come under tension.
Holding-down bolt tension T and concrete compression C form a couple at lever arm α to resist the moment.
← not strictly correct (the true lever arm is slightly larger), but conservative — a safe simplification.
T → total tension on all bolts on one side. If n = number of bolts on one side, tension in one bolt:
σbolt → 100 MPa (typical). Find diameter d.
Bolt embedment into the concrete pedestal — bond stress along the embedded length resists the pull-out tension T₁.
Find lemb.d from the bond strength τbd of concrete.