Structural Steel Design / Column Bases / Part 1 of 2

Column Bases — Slab Base, Gusseted Base & Grillage Foundation

Converted from handwritten notes — Steel Structure 3.pdf, pages 1–19

Doc No.SS-03-01
StatusDraft — Awaiting Review
Converted17-08-2026
Approved—

Types of Column Bases

The various types of column bases that are used are:

1. Slab base

shear slab base

Slab base — a thick base plate under the column, direct-bearing on a concrete pedestal. Mostly used for purely axial loading.

2. Gusseted base

P M

Gusseted base — gusset plates and angle cleats transfer load into a wider base plate on a stepped pedestal. Adopted for axial loading combined with heavy moments.

3. Grillage foundation

Baseplate column Top tier beam encased in concrete Bottom tier beam L

Grillage foundation (plan below, elevation above) — stacked, orthogonal tiers of rolled-steel joists encased in concrete. Adopted in temporary construction and when a heavy load must be transferred at shallow depth.

Slab Base Design (WSM)

In case of an axially loaded condition, a square plate may be adopted.

thickness = t B B α β

H-section column welded to a square base plate B × B, thickness t. α and β are the overhang distances beyond the flange/web on each side.

max(α,β)=a

a = larger overhang

min(α,β)=b

b = smaller overhang

σpr.concrete=fck4
thickness of base plate=3Wσbs(a2−b24)

as per IS code, for the axial loading condition.

stress from bottom w = P/B²

Uniform bearing pressure w = P/B² acting upward on the underside of the base plate for the purely axial case.

σbs: permissible bearing stress in solid section = 0.75 fy

Permissible Bearing Stress & Yield-Line Moments

Section typePermissible bearing stress
Flanged section0.67 fy
Solid section0.75 fy

For the base plate under a uniform pressure w (N/mm²), a strip of unit width (1 mm) is analysed as a cantilever fixed along the flange/web edges, spanning the overhangs a and b:

1 3 3 2 1 2 a b 1 mm × t strip

Cantilever strips 1-1 (spanning a, moment M₁₁) and 2-2/3-3 (spanning b, moment M₂₂) around the H-section footprint.

M11=w⋅1×a×a2=wa22 N·mm M22=wb22 N·mm
σ11=M11(1×t2/6) σ22=M221×t2/6

The plate bends biaxially at once, so the true combined stress accounts for the Poisson effect between the two directions:

σE=σ11−μσ22E⇒σ=σ11−μσ22=M11−μM221×t2/6

For safety:

M11−μM22(1×t2/6)≤σbs (wa22−μwb22)(1×t2/6)≤σbs
t≥3Wσbs(a2−μb2)

(the code has taken μ = 0.25 for WSM)

Base Plate Under Axial Load + Moment

P M f₁ f₂ f₃ f₄ P/A − My/I P/A + My/I

Base plate under eccentric load: linearly-varying bearing pressure P/A ± My/I, from a peak of f₄ (P/A + My/I) down to f₁ (P/A − My/I), with intermediate values f₂, f₃ through the H-section footprint width.

3 1 B a b 2 This junction is critical.

The flange-web junction (near the highest-stress zone) is the critical location where M₁₁ and M₂₂ are checked.

Under non-uniform pressure, the cantilever strip moments are found from the average intensity over the tributary area, with the resultant located at its centroid:

M11=(f4+f32)a×1mm×x¯ x¯=2f4+f3f4+f3×a3 M22=f3×b×1×b2
σ₁ − μσ₂ ≤ σbs

Bearing pressure & the "no tension at base" condition

With M = P·e, treating the base plate/pedestal as a rectangular section L × B under combined axial load and moment:

PL×B+MBL2/6≤σc
PLB(1+6eL)≤σc

σc = permissible stress in concrete. Choose L, find B.

For no tension anywhere at the base, the minimum edge pressure must stay non-negative:

PLB(1−6eL)≥0⇒1≥6eL⇒e≤L6
L>6e

for no tension at base, with e = M/P.

LSM (Column Base)

Pu→γfP Mu→γf⋅M
σ1−μσ2≤1.2fyγmo M11−μM22(1×t2/6)≤1.2fyγmo

σbs → 1.2fy/γmo. σc → 0.45fck (marked in the source as revised to 0.6fck — see note below).

e=MuPu PuLB+MuBL2/6≤0.45fck PuLB[1+6eL]≤0.45fck

Choose L & find B. For no tension at base: L > 6e.

0.45fck vs. 0.6fck For solving questions, we can take the permissible compressive stress in concrete as 0.45fck, both for the purely axial load condition and for loading with moment. However, as per IS code recommendation, for the linearly varying stress condition (i.e. axial + moment), the maximum stress in concrete can be taken as 0.6fck instead.
0.45fck f₁ f₁ ≱ 0.6fck

Uniform 0.45fck limit (pure axial case) vs. the linearly-varying pressure diagram (axial + moment case), where the peak edge pressure f₁ is capped at 0.6fck.

PuB2≤0.45fck⇒find B?

Using the yield-line moments M₁₁ = wa²/2 and M₂₂ = wb²/2 with a > b, and μ = 0.3 in LSM:

(wa22−μwb22)6t2≤1.2fyγmo t≥6W1.2×2(a2−μb2)(fy/γmo)
t≥2.5W(fy/γmo)(a2−0.3b2)

(μ taken as 0.3 in LSM)

In WSM → μ → 0.25. In LSM → μ → 0.3.

Worked Example — Slab Base with Welded Connection (WSM)

Column SC200 (I-section) is to support an axial compressive load of 700 kN and moment of 55 kNm. Design the column slab base assuming the bearing ends to be milled. Allowable bearing stress of concrete in footing is 3.75 MPa.

Also design the welded connection between the slab base and column. Thickness of column flange = 15 mm; take the strength of a 1 mm fillet weld per mm length to be 76 N. Permissible bending stress in plate is 175 N/mm². Take μ = 0.25.

15mm 200mm 200mm

Column SC200 — 200 mm × 200 mm I-section, flange thickness 15 mm.

Milled vs. non-milled column end NOTE: If the column end is milled, the direct load is assumed to be transferred to the base through direct bearing, and the connection will be designed only to carry the moment. However, if the column end is not milled, both direct loading and moment will be assumed to be transferred through the connection.
milled

Column-end milled and seated directly on the slab base; connection welds carry only the moment.

a = 200 mm (larger overhang direction), b = 180 mm (smaller overhang direction).

PLB(1+6eL)≤3.75 MPa e=MP=55700=78.57 mm L>6e⇒L>471.42 mm
adopt L=600 mm
700×103600×B(1+6×78.57600)≤3.75
B≥555.53 mm⇒B=560 mm
560/2 200 0.446 MPa 3.72 MPa 2.63

Linearly-varying bearing pressure across L = 600 mm, ranging from 0.446 MPa to 3.72 MPa, with 2.63 MPa at the column centreline (200 mm from the high-pressure edge).

700×103600×560(1+78.57×6600)=3.72 MPa

Cantilever moments for a = 200 mm, taking the average pressure over the tributary triangle-trapezoid area (per 1 mm width):

M11=(3.72+2.632)×200×1×[2×3.72+2.633.72+2.63]×2003
M11=67133.33 N·mm
M22=wb22=2.63×18022
M22=42606 N·mm

These moments are for a 1 mm width strip.

M11−μM22(1×t2/6)≤175 MPa, μ=0.25
t≥44 mm⇒let's adopt t=45 mm

Weld design for the moment connection

Since the column end is milled, the weld is designed only to resist the force T (and equal compression C) arising from the moment, taken as a couple at the flange centres, 200 mm apart:

M200=CT=1 T=55×106200=275 kN

The weld will be designed only to resist force due to moment, because the column end is milled (direct load already transfers by bearing).

ℓ×0.7s×σsw≥275×103 N

1 mm fillet weld of size s = 1 mm carries 0.7 × 1 × σsw = 76 N per mm length.

Largest weld size that can be provided at the flange (given flange t = 15 mm) is t − 1.5 = 13.5 mm; the minimum size corresponding to a 45 mm-thick base plate is 10 mm. We adopt size of weld = 13.5 mm.

ℓ required=275×10313.5×76=268.03 mm

But the available flange width is only 200 mm, so welds must also be provided on the inner side of the flange:

200×13.5×76+ℓ×13.5×76=275×103 ℓ≥80.03 mm⇒adopt ℓ=90 mm
Provide 200 mm outer-side weld + 45 mm inner-side weld, both of 13.5 mm size

Worked Example — Same Problem by LSM

Solve the above problem using LSM. Take μ = 0.3, grade of base concrete M20, grade of steel in weld Fe410.

Pu=1.3×700=1050 kN Mu=55×1.5=82.5 kN·m e=MuPu=78.57 mm, 6e=471.42 mm
PuLB(1+6eL)≤0.45fck

1050×10³/(600×B) with fck = 20 MPa, adopting L = 600 mm.

B=347.2 mm⇒adopt B=350 mm, L=600 mm
1.07 6.309 8.928 200

LSM bearing pressure diagram — 1.07 to 8.928 MPa across L = 600 mm, with 6.309 MPa at the column centreline; a = 200 mm, b = 75 mm.

M11=(8.928+6.3092)×200×1×(2×8.928+6.3098.928+6.309)×2003
M11=161.1×103 N·mm
M22=wb22=6.309×7522=17.744×103 N·mm
M11−μM22(1×t2/6)≤1.2fyγmo (161100−0.3×17744)6t2≤1.2×2501.1
t≥58.54 mm⇒t adopt=60 mm
ℓ×0.75×fu3γm1≤Mu200

fu = 410 N/mm², Mu/200 = 82.5×10&sup6;/200, γm1 = 1.25

s adopt=13.5 mm, ℓ=230.5 mm

Provide ℓ = 200 mm outer side + 45 mm inner side.

When the Base Loses Contact (ℓ < 6e)

In case the length of the base is fixed and ℓ < 6e, tension will develop at the base.

Tension Compression 2P / [3(L/2−e)B] 3(L/2−e) Tension

Loss of contact over part of the base — final contact length shrinks to 3(L/2 − e), with peak compressive stress rising accordingly; the opposite side goes into tension, requiring holding-down bolts.

final contact length=3(L2−e) max compressive stress=2P3(L2−e)B

In this case we need to design the holding-down bolt also, because the bolt will come under tension.

P M T C α

Holding-down bolt tension T and concrete compression C form a couple at lever arm α to resist the moment.

Tα=m T=mα

← not strictly correct (the true lever arm is slightly larger), but conservative — a safe simplification.

T → total tension on all bolts on one side. If n = number of bolts on one side, tension in one bolt:

T1=Tn

Bolt diameter and embedment length

T1(πd24×0.78)≤σbolt

σbolt → 100 MPa (typical). Find diameter d.

lemb.d T₁

Bolt embedment into the concrete pedestal — bond stress along the embedded length resists the pull-out tension T₁.

lemb.d×πd×τbd≥T1

Find lemb.d from the bond strength τbd of concrete.