Structural Steel Design / Connections
The various types of welds used are:
Square butt weld — full-depth (complete penetration) weld, used for thin plates (t up to 8 mm).
Incomplete penetration — the weld metal does not fill the full depth t, leaving an unfused gap at the root (a weak plane).
Weld cross-section preparation shapes — V, U and J weld, used for thicker plates (t up to 40 mm) to control penetration and metal volume.
Located among the scanned pages that duplicate earlier content — merged in here as it continues the butt-weld thickness discussion above.
Double U/V/J weld — welded from both faces, used once plate thickness exceeds ~40 mm.
Plan view of a butt weld along the complete length ℓ of the joint.
where ℓ = length of weld, t = throat thickness, σt = permissible tensile stress of weld.
Lap-jointed plate connected by side and end fillet welds along its edges.
Convex fillet weld face develops compression at the throat when pulled; a concave face develops tension there instead.
Side fillet welds resist the applied load entirely by shearing on their throat plane.
ℓ = length of weld, tt = thickness of throat, σs = permissible shear stress in fillet weld.
Plug weld — a circular hole cut through the overlapping plate, filled with weld metal to connect the plates through the plate thickness.
Plug welds make the connection between overlapping plates more effective, redistributing stress in the plate more uniformly. They should not be accounted for in shear-strength calculation.
Slot weld — L = weld length on each side, b = slot width; welded around the full periphery of the slot.
If the overlap between the plates is limited so that the length of connection cannot simply be increased, a slot is cut in the plate and its edges are welded — this is called slot welding, giving the additional weld length Ls down the middle of the slot.
Standard weld symbols — fillet (△), square butt (‖), single-V (Y), double-V (X), all-round circle, and the field-weld flag.
Weld symbol reading (top): weld size/length/pitch called out arrow-side vs. other-side. Bottom-left: 6 mm and 5 mm fillet weld callouts. Right: 120 mm staggered-fillet spacing with the 75/150 sequence and gap noted on the symbol.
Butt weld tensile strength — throat thickness tc across the full plate depth.
σT = tensile strength of weld.
tc = thickness of thinner plate being joined.
Plates of unequal thickness t1 > t2 — the thicker plate is tapered where the difference is excessive.
Left term — net section rupture. Right term — gross section yielding. γmb = 1.25.
WSM vs LSM stress-strain idealisation, and net tensile area An across a threaded bolt shank under axial pull P.
| Fe410 grade — numeric check (per unit An) | |
|---|---|
| fu = 410 MPa, fy = 250 MPa | — |
| Net section rupture: 0.9×410 An / 1.25 | = 295.2 An |
| Gross section yielding: (250 / 1.1) × 0.78 An | = 291.37 An |
Excessive yielding may lead to a non-functional joint even before rupture — this is why the gross-section yielding check is retained even though it is not always the smaller value.
Vdsb = design shear strength of bolt. Vdpb = design bearing strength of bolt.
γm1 = 1.25. fu = ultimate strength of bolt.
lj = length of joint (end-to-end bolt spacing); lg = grip length of the connection.
applies when lj > 15d (i.e. number of bolts = 7 or more in the line); d = nominal (shank) diameter of bolt.
applies when lg ≠ 8d and lg > 5d; note βlg ≠ βlj.
applies if packing thickness > 6 mm. tpk = thickness of packing plate (mm).
e/3d0 governs end-distance bearing; p/3d0 − 0.25 governs pitch-distance bearing.
For safety of the joint, the above interaction formula should be satisfied.
A rigid connecting plate splits the applied 2T equally as bolt tension T with no additional force.
A flexible connecting plate deflects (blue curve) under 2T — the flange tips lever against the bolt, adding a prying force Q, so each bolt actually carries T + Q rather than T.
Due to flexibility of connection, in connections where bolts are required to transfer direct tension, the bolts are subjected to an additional force called prying force, Q.
| Fe410 grade — governing strength of plate without hole deduction | |
|---|---|
| fu = 410 MPa → 0.9 fu / 1.25 | = 295.2 |
| fy = 250 MPa → fy / 1.1 | = 227.27 (governs) |
Strength of plate without deduction for holes is taken as the minimum corresponding to gross section yielding strength and net section rupture strength. Normally, gross section yielding strength comes out to be smaller, hence in the denominator we write the gross section yielding strength.
Bolts are M20 of grade 4.6. Find the maximum load P that can be safely applied. Bracket plate thickness = 10 mm; column flange thickness = 8 mm.
5-bolt eccentric bracket (dimensions in mm) — bolts 1 and 2 are the most critical, each at radius r = √(60² + 80²) = 100 mm from the bolt-group centroid, at eccentricity e = 250 mm from the load line.
Bolts 1 and 2 are the most critical bolts. Direct (shear) load per bolt, from n = 5 bolts sharing P equally:
Twisting-moment force on bolt 1, with e = 250 mm and r = √(60² + 80²) = 100 mm, distributed over 4 bolts each at radius r (bolt at the centroid contributes nothing):
Angle θ between Fd1 (vertical) and FT1 (perpendicular to the 100 mm radius line) at bolt 1, with cosθ = 60/100 = 0.6, from the true 60–80–100 triangle.
Resultant force on bolt 1 (combining Fd1 and FT1 with the angle θ between them, cosθ = 60/100 = 0.6):
For safety of the joint, F1 < bolt value ⇒ 0.769 P < bolt value.
Assuming the shearing plane passes through the root of the thread.
If not given, plate grade is assumed as Fe410. p is taken as the minimum pitch distance = 60 mm (to be on the safer side).
Bolt value = min(Vdsb, Vdpb) = min(45.27, 78.72) = 45.27 kN = 45,270 N.
The 58.86 kN limit is the factored load capacity; dividing by the load factor (1.5) gives the maximum safe working load:
Find the efficiency of the lap joint shown below. Bolt is M20 grade of property class 4.6; plate is Fe410 grade with fy = 250 MPa. Assume shear plane cuts the thread.
4-bolt lap joint, plate width 180 mm × 20 mm thick, bolts on a 30–60–30 (mm) horizontal grid and 60 mm pitch vertically, 20 mm hole clearance each side.
An = (B t − 3 d0 t)
Block shear failure surface — shear along the two bolt-line edges (Agv/Avn) combined with tension across the end row (Atn/Atg).
| Area | Computation | Value |
|---|---|---|
| Avg | 90 × 20 × 2 | 3600 mm² |
| Atn | (120 − 44) × 20 | 1520 mm² |
| Avn | (90 − 1.5×22) × 20 × 2 | 2280 mm² |
| Atg | 120 × 20 | 2400 mm² |
Path 1: fyAvg/(γmo√3) + 0.9fuAtn/γm1 = 921.08 kN. Path 2: 0.9fuAvn/(√3γm1) + fyAtg/γmo = 934.04 kN.
βlj = βlg = βpk = 1 for this joint size.
Bolt value = min(45.27, 149.07) = 45.27 kN (minimum of the two). With 6 bolts total in the joint, minimum of shearing & bearing strength of joint = 6 × 45.27 = 271.6 kN.
| Failure mode | Strength |
|---|---|
| Bolt shear/bearing (6 bolts) | 271.6 kN |
| Tearing strength of plate | 673.06 kN |
| Block shear strength of plate | 921.08 kN |
Strength of plate without deduction for holes:
Found among the duplicate-scan pages, inserted here as its own independent worked example.
Determine the shear and bearing capacity of an M20 bolt of property class 8.8 connecting 10 mm thick plates as shown, in single shear. Plate is Fe410 grade. Assume shear plane cuts the shank.
Two M20 bolts, end distance 33 mm, pitch 50 mm, connecting a 10 mm lapped plate to a 10 mm plate in single shear.