Hydrology / Irrigation / Part 7
Dam — a kind of obstruction or barrier constructed across a river or stream such that water is collected on its upstream side. This pool of water collected on the upstream side is called the reservoir.
Arch dam — convex upstream, curved in plan.
Steel dam — steel plate on braced framework.
Typical cross-section of a gravity dam. U/S face can be inclined or vertical; the line of the U/S face (or, if inclined, the axis/base line of the dam) is used to measure the length of the dam. A drainage gallery relieves the uplift pressure exerted by seepage water.
Length of the dam is calculated along the axis of the dam. Drainage gallery is provided to release the uplift pressure exerted by seepage of water.
1 — Weight of the dam. It is named the stabilizing force, and it acts along the C.G. of the cross-section.
Weight of the dam, split into simple areas W₁, W₂, W₃ (per metre run of the dam).
where γc = 25 kN/m³ (unit weight of dam concrete).
2 — Water force. The main destabilizing force on the upstream side. Tail-water depth helps in stability.
Horizontal water force P (upstream head H) and tail-water force Pw / PH₂ (downstream head H'), each acting at one-third the respective head above its base; V₁, V₂, V₃ are the weights of water resting on an inclined U/S face.
3 — Uplift pressure. If water of height H is stored on the U/S side, water has a tendency to seep through the pores and fissures of the material in the body and foundation of the dam, and through the joints between the body of the dam and the foundation. This seeping water exerts an upward pressure.
Uplift pressure distribution — without a drainage gallery (straight-line variation from γwH at heel to γwH' at toe) and with a gallery placed at least 2 m from the U/S face (intensity dropped there to γw[H' + ⅓(H−H')]).
4 — Earthquake forces. Earthquakes are caused by sudden sliding of tectonic plates in the interior of the earth. The point of sudden sliding is called the focus, and it lies within the top 100 km of depth. The vertical projection of the focus on the earth's surface is called the epicentre.
Earthquakes set up random vibrations in the earth's crust, resolved into three mutually perpendicular directions, causing the structure to vibrate. These waves impart acceleration to the foundation of the dam, gradually transferred to the body of the dam. For design purposes, acceleration is resolved into horizontal acceleration (αh) and vertical acceleration (αv), expressed as a % of g: α = 0.1g to 0.15g, typically αh = 0.1g, αv = 0.05g.
αv acting upward → +ve sign; downward → −ve sign.
Horizontal acceleration causes two effects — horizontal inertial force, and hydrodynamic force.
When the reservoir is full, αh acting toward the reservoir (into the dam) is the worst case — the inertial force FH then acts downstream, adding to the destabilizing forces. When the reservoir is empty, the worst case reverses: αh acting away from the dam body (toward the reservoir side) is the worst case, since there is no water weight to counter it. Earthquake forces act at the C.G. of the section.
If αh acts toward the U/S side, an extra pressure is exerted by the water on the dam — called hydrodynamic force. According to Von Karman:
Von Karman pressure distribution — parabolic, resultant Pe acts at 4H/3π = 0.424H above the base.
5 — Silt pressure. Silt deposited in the reservoir is somewhat impervious and helps minimize the uplift pressure acting on the dam.
Silt pressure acting as an active earth pressure triangle over the deposited silt height.
6 — Wave pressure. Waves are generated on the surface of the reservoir by blowing wind, causing a pressure toward the D/S side. Wave pressure depends on wave height:
Wave pressure distribution — peak intensity pe = 2.4γwhw at still-water level, over an effective height ⅛hw; the resultant Pe acts at ⅛hw above SWL.
7 — Ice pressure. In cold areas, the dam face has to resist thrust exerted by expanding ice. A value of 500 kN/m² is generally applied on the face of the dam over the anticipated area of contact of ice with the body of the dam.
8 — Wind pressure. Can be taken as 1–1.5 kN/m² of the exposed area.
1 — Sliding.
Sliding resistance is provided by friction at the base, μΣV, resisting the destabilizing horizontal force ΣH.
For large/high dams, for economic and precise design, the additional shear strength of the joint is also considered. To increase shear strength, the foundation is stepped at the base.
By overturning about the toe.
Overturning about the toe: destabilizing moment Mo (from ΣH) vs. resisting moment MR (from W).
Crushing / compression failure.
Resultant R meets the base at eccentricity e from the centre-line, producing a trapezoidal (or triangular) base-pressure distribution from σH (heel) to σT (toe).
For no crushing, σT < σconcrete. But σT is not the maximum direct stress produced in the concrete, because this plane also contains a shear-stress component. To determine the maximum principal stress, consider a small element at the toe.
Since σ2 is a normal principal stress (no shear stress on the plane where water pressure acts, since water pressure is normal), and since principal planes are normal to each other, σT (on the base plane, at angle α to the principal plane) relates to σ1 and σ2 by the transformation equation:
Therefore, for no crushing failure, σconcrete > σ1. If there is no tail-water depth, σ2 = 0.
For no tension at the heel, σH ≥ 0:
Therefore the resultant must lie within the middle third of the base.
The figure below shows the section of a gravity dam built up of concrete. Calculate the stresses at heel and toe. Assume the weight of concrete as 23.5 kN/m³. Neglect EQ forces.
Dam section: RLs 289 (crest), 285 (FRL/U/S water), 280 (D/S berm), 211 (D/S tail-water), 205 (base); 6 m crest width, 8 m gallery offset, 56 m total base width.
H = 285 − 205 = 80 m; H' = 211 − 205 = 6 m; tanθ = 75/50 ⇒ x = 4 m (horizontal offset of the vertical face portion below crest).
| Force | Calculation | FV (kN) | FH (kN) | MR (kN·m) | Mo (kN·m) | L.A. (m) |
|---|---|---|---|---|---|---|
| W₁ | 6×84×1×23.5 | 11844 | — | 627732 | — | 50+6/2=53 |
| W₂ | ½×50×75×1×23.5 | 44062.5 | — | 1468750 | — | 2×50/3=33.33 |
| V | ½×6×4×9.81 | 117.72 | — | 156.96 | — | 4/3=1.33 |
| PH1 | ½×80²×9.81 | — | 31392 | — | 837120 | 80/3=26.67 |
| PH2 | ½×6²×9.81 | — | −176.58 | 353.16 | — | 6/3=2 |
| U₁ | 56×6×9.81 | −3296.16 | — | — | 92292.48 | 56/2=28 |
| U₂ | ½×48×24.67×9.81 | −5808.3 | — | — | 185860.3 | 48×2/3=32 |
| U₃ | 8×24.67×9.81 | −1936.10 | — | — | 100679.28 | 48+8/2=52 |
| U₄ | ½×(80−30.67)×9.81×8 | −1935.91 | — | — | 103237.82 | 48+8×2/3=53.33 |
| Sum | 43047.97 | 2096992.12 | 1319189.88 | |||
Since MR > Mo, there will be no overturning.
Since e > B/6 (= 9.33 m), there will be tension at the heel.
Principal stress at the toe, with tanθ = 75/50 ⇒ tanα = 50/75 = 2/3, tan²α = 4/9, sec²α = 13/9, and σ₂ = 6γw = 58.86 kN/m² (tail-water):
σheel = −49.96 kN/m² (tension), σtoe = 1587.39 kN/m², σ₁ ≈ 2214.5 kN/m², τ₀ ≈ 1019.2 kN/m²
Elementary profile — a right-angle triangle, zero width at top, base width B at the bottom. Shape is similar to the hydrostatic force distribution acting on the dam.
We consider three main forces acting on a gravity dam of elementary profile:
c — uplift pressure intensity factor: c = 1 for a full reservoir, c = 0 for an empty reservoir.
For no tension at the toe, with emax ≤ B/6, taking emax = B/6:
Let the resultant of W, P and U pass through the outer-most point of the middle third, so e = B/6. Taking moments about the outer-third point B':
Dividing throughout by ½γwH, and using Gc = γc/γw (relative density of the dam material):
With e = B/6, σT works out (using B/H = 1/√(Gc−c) from the no-tension condition) to:
Since the tail-water depth is neglected, σ2 = 0, and tanα = B/H:
The maximum height of a low gravity dam made up of concrete having relative density 2.5 and safe allowable stress of the foundation material 3.87 MPa, without considering uplift force.
Gc = 2.5, c = 0 (uplift not considered):
H = 112.71 m
The base width of a gravity dam is 25 m. The material of the dam has specific gravity of 2.56, and the dam is designed as an elementary profile, ignoring the uplift. What is the approximate allowable height of the dam?
H = 40 m