Irrigation may be defined as the process of supplying water to the field by artificial means for the purpose of cultivation, that is, in accordance with the “crop requirement” throughout the “crop period” for optimum growth of crops.
(a) Direct advantages
(b) Indirect advantages
Irrigation is classified as follows:
Surface irrigation is a method in which water is directly applied to the soil surface, either by means of gravity or pumping. It is best suited for soils having low and moderate permeability, and lands with uniform terrain. Surface irrigation can be further classified as flow irrigation and lift irrigation.
If water is available at a higher elevation and is supplied to the lower level under the action of gravity, it is called flow irrigation.
Flow irrigation is further classified as:
(a) Perennial irrigation — constant and continuous water supplied to the field as per requirement of crops throughout the crop period.
(b) Flood irrigation / inundation — in this system a large quantity of water is applied during floods to the land to be cultivated, causing saturation of the field; excess water is then drained off and the field can be used for cultivation.
If water is lifted by some mechanical or manual means and supplied to the agriculture field, it is called lift irrigation — ex. pump, well and tubewells. It is costlier than flow irrigation.
Free (wild) flooding — ditches excavated in the field carry water from the main canal; once water leaves the ditches through the outlets, no attempt is made to control its flow.
In this method, ditches are excavated in the field and water from these ditches flows across the field. After water leaves the ditches, no attempt is made to control the flow, hence it is also called wild flooding.
Border strip flooding — land divided into strips separated by low levees (“borders”) along the slope of the ground, each strip fed from a gate at its head.
Land is divided into a number of strips separated by low levees called borders, along the slope of the ground.
Relation between discharge through the ditch (Q), rate of infiltration of soil (f), average depth of flow over the strip (y), area irrigated (A), and time required to irrigate the area (t).
Constant discharge Q enters at the gate and spreads over the area A already covered, with a constant depth of flow y; the wetted front advances by dA in time dt.
Let the discharge into the field be constant Q, with constant depth of flow y. Over an increment dA in time dt, inflow equals infiltration loss plus the change in ponded volume:
Holding Q, y, f constant and integrating:
When t = 0, A = 0:
Substituting back:
Time required to irrigate a given area A with a particular discharge Q.
Maximum area that can be irrigated with a particular discharge (Amax): as t → ∞, ln[Q/(Q−Af)] → ∞, so Q/(Q−Af) → ∞, which requires Q−Af → 0. At this condition A → Amax:
Size of the strip will depend on discharge Q, soil characteristic f, and slope of the field.
For the border strip method of irrigation, determine the time required to irrigate a strip of land 0.04 ha in area from a tube well with a discharge of 0.02 cumec. The infiltration capacity of the soil may be taken as 5 cm/hr, and the average depth of flow on the field is 10 cm. Also determine the maximum area that can be irrigated from this tube well.
t = 39.05 min
Amax = 0.144 ha
Check flooding — the field is divided into small nearly-level plots (checks) enclosed by low levees on all sides, each fed from the lateral ditch.
In this method the land to be irrigated is divided into small plots or check areas with low flat levees constructed having a vertical height of 5 to 10 cm; the plot area is nearly horizontal. Irrigation water is applied by filling the plots with water up to the desired depth without overtopping the levees, and water is retained and allowed to infiltrate into the soil.
Ring/basin method — a special form of check flooding used for orchards, with a separate circular basin made for each tree.
This method is a special form of the check basin method, used for irrigation of orchards. In this method a separate circular basin is made for each tree.
Furrow irrigation — long narrow field channels (furrows) carry the flow; water infiltrates and spreads laterally into the ridge between furrows, wetting only 20–50% of the surface.
Water flowing in the furrows infiltrates into the soil and spreads laterally to irrigate the land between the furrows. In this method 20–50% of the area of the land is wetted, which results in less evaporation. It is suitable for row crops such as wheat, maize, cotton, groundnut etc.
In the sprinkler irrigation method, water is applied to the land in the form of a spray through a network of pipes and pumps.
Advantages
Disadvantages
In this method water is directly and slowly applied to the root zone of the plants using small-diameter plastic pipes with drip nozzles or drippers. Water is applied at a very low rate, 2–10 lit/hr, to keep the soil moisture in the desired range for plant growth.
As every water is not suitable for human beings, on the same note every water is not suitable for plants also. Quality of irrigation water is generally judged on the following factors.
When fine sediment from river water is deposited on sandy soil, fertility is increased, whereas if the sediment is derived from an eroded area, it will reduce fertility by decreasing the permeability.
The most abundantly found salts are harmful to plants if present in excess, because they reduce the osmotic activity of plants and may prevent adequate aeration. The quality of irrigation water is therefore determined by the concentration of salts in the water; this concentration of soluble salts (salinity) is determined by measuring the electrical conductivity (EC) of the water, expressed in µmho/cm (micromhos per cm).
| Classification | EC @ 25°C (µmho/cm) | Use in irrigation |
|---|---|---|
| Low salinity water (C-1) | < 250 | Can be used for all crops on all soil |
| Medium salinity water (C-2) | 250–750 | Normal salt-tolerant plants can be grown if leaching is done |
| High salinity water (C-3) | 750–2250 | High salt-tolerant plants with special measures |
| Very high salinity water (C-4) | > 2250 | Not suitable |
Source margin note: each successive threshold is roughly ×3 the one before it (250 × 3 = 750, 750 × 3 = 2250).
Salt concentration is also sometimes expressed as the salinity concentration of the soil solution (Cs):
Cs > 700 ppm is harmful for certain plants; Cs > 2000 ppm is harmful for every plant.
When the percentage of sodium ions in the total exchangeable cations exceeds 10%, aggregation of soil particles breaks down and the soil becomes of poor tilth. The proportion of sodium ions present in the soil is determined by a factor called the Sodium Absorption Ratio (SAR):
[ ] denotes concentration expressed in equivalent per million (epm).
| Classification | SAR | Use |
|---|---|---|
| Low sodium water (S-1) | 0–10 | Can be used for all crops on all soils |
| Medium sodium water (S-2) | 10–18 | Can be used on coarse-grained soil |
| High sodium water (S-3) | 18–26 | Can be used after leaching if good drainage is provided |
| Very high sodium water (S-4) | > 26 | Not suitable |
High concentration of bicarbonates results in precipitation with Ca2+ and Mg2+ ions, thereby reducing their concentration in solution. Hence it leads to an increase in SAR value.
The major source of boron is soaps.
Presence of selenium in water is harmful for all crops.
When crops irrigated with highly contaminated water are eaten directly without being cooked, it may pose/cause many problems.
Classify irrigation water having the following characteristics: concentration of ions of sodium, calcium and magnesium are 22, 3 and 15 milli-equivalent per litre respectively, and the electrical conductivity is 200 µmho/cm at 25°C.
SAR = 7.333 lies in the range 0–10 → the water is classified as low sodium water, S-1.
EC = 200 µmho/cm @ 25°C lies between 0–250 → it is low saline water, C-1.
Water can be classified as C-1 S-1.