Hydrology / Ground Water Hydrology

Ground Water Hydrology

Converted from handwritten notes — Hydrology 09 Ground Water Hydrology.pdf, 17 pages

Doc No.HYD-09
StatusDraft — Awaiting Review
Converted27-07-2026
Approved—

Subsurface Water Zones & Aquifer Types

Zones of Subsurface Water

Below ground level, moisture occurs as hygroscopic water (adsorbed on soil particle surfaces), capillary water (held by surface tension), and gravitational water (free to drain under gravity). The vertical profile is divided as follows.

Hygroscopic water Capillary water Gravitational water Root zone Soil water zone / vadose zone Zone of aeration Atmospheric pressure → Capillary fringe Zone of saturation

Vertical zonation of subsurface water: hygroscopic/capillary/gravitational water at the surface, the vadose zone (zone of aeration) above the capillary fringe, and the zone of saturation below the water table, where pore-water pressure increases linearly with depth (arrow length ∞ pressure).

Soil water zone The zone from which water can be extracted by plant roots is called the soil water zone or vadose zone. If saturation occurs within the root-zone depth itself, we say water logging has occurred.

Aquifer, Aquitard, Aquiclude, Aquifuge

The various water-bearing strata below the ground water table are classified on the basis of how easily water can be pumped out of them.

TermBehaviourExample
AquiferContains a lot of water and yields it easily due to high permeabilityCoarse sand layer / gravel layer
AquitardOnly seepage is possible through this layer; yield is insignificantSandy clay layer
AquicludeHighly porous but not permeableClay layer
AquifugeNeither porous nor permeableRocky layer

Confined & Unconfined Aquifer

Perched aquifer Water table Aquiclude Confined aquifer Rocky stratum Potentiometric surface

Unconfined (water-table / phreatic) aquifer above an aquiclude, overlying a confined (artesian) aquifer whose potentiometric surface rises above the local water table; a perched aquifer sits on an isolated clay lens within the vadose zone.

In an unconfined aquifer, the water table fluctuates freely due to addition or withdrawal of water. In the confined aquifer, if the potentiometric surface falls (because of pumping), the effective stress in the soil increases and the soil gets compressed.

Aquifer Properties

An aquifer performs two functions: (1) storage of water, and (2) transmission of the stored water.

Specific Yield & Specific Retention

Water Water Soil solids Vsoil Vdrained Vretained

A unit volume of saturated soil, Vsoil, drains a volume Vdrained under gravity and retains a volume Vretained against it.

Sp. yield=VdrainedVsoil Sp. retention=VretainedVsoil
Sp. yield+Sp. retention=porosity

Storage Coefficient (S)

In the case of a confined aquifer, the volume of water yielded by unit plan area of the aquifer, when the potentiometric surface falls by unity, is called the storage coefficient (S).

drop in potentiometric level D Storage coefficient (S)

Confined aquifer of thickness D — the storage coefficient S is the volume released per unit plan area for a unit drop in the potentiometric surface.

Specific Storage (Ss)

The volume of water released from unit volume of aquifer due to unit drop in potentiometric surface is called specific storage (Ss).

Ss=SD
S — storage coefficient
D — depth (thickness) of confined aquifer
S=γwnd1Kw+1nEs
n — porosity of soil
Kw — bulk modulus of water; 1/Kw — compressibility of water
Es — modulus of elasticity of soil grains
d — thickness of confined aquifer (= D)

Coefficient of Transmissibility (T)

From Darcy's law, for a confined aquifer of thickness D and unit width:

q=KiA=Ki(D×1)=(KD)i=Ti
T=KD

Storage coefficient and coefficient of transmissibility are important aquifer parameters, determined by carrying out a well pumping test.

One-Dimensional Ground Water Flow

Case 1 — Confined Flow Between Two Water Bodies

h1 h2 dx x D L

Confined aquifer of thickness D connecting two water bodies at heads h₁ and h₂ — the piezometric head varies linearly (straight-line) with distance x.

q=KiA=K−dhdx(D×1)

Separating variables and integrating from 0 to x (h = h₁ at x = 0):

qdx=−KDdh⇒qx=KD(h1−h)

A straight-line variation of h with x.

At x = L, h = h₂, so qL = KD(h₁−h₂). Combining with the general result:

xL=h1−hh1−h2
q=Kh1−h2L(D×1)

Case 2 — Unconfined Flow Between Two Water Bodies

h1 h2 h x L parabolic

Unconfined aquifer between two water bodies — the water table follows a parabolic (Dupuit) curve, falling monotonically from h₁ to h₂.

q=KiA=K−dhdx(h×1)
qdx=−Khdh⇒qx=K(h12−h2)2

A parabolic variation of h with x.

At x = L, h = h₂:

xL=h12−h2h12−h22
q=Kh1−h2Lh1+h22×1

Case 3 — 1D Flow With Recharge (Ground Water Divide)

Uniform recharge R (m³/m·s) infiltrates over the whole strip. The hydraulic gradient is assumed constant throughout the depth.

R (recharge) h1 h2 GW divide x x=a L

Recharge raises the water table into a mound whose peak (the ground water divide, x = a) lies between the two reservoirs; on either side flow drains toward h₁ and h₂ respectively.

Consider a strip of width dx: inflow q, outflow q+dq, with dq = R·dx, so dq/dx = R. Using q = K(−dh/dx)(h×1) = −(K/2)·d(h²)/dx:

R=−K2d2(h2)dx2

Integrating twice and applying h = h₁ at x = 0 and h = h₂ at x = L gives the general solution:

h2=h12−(h12−h22)xL+RKx(L−x)

The flow at any section, qx = −(K/2)·d(h²)/dx, works out to:

qx=Rx−RL2+K2L(h12−h22)

The ground water divide is the highest point of the water table, located where dh/dx = 0, i.e. qx = 0 at x = a:

a=L2−K2RL(h12−h22)
At x = a, qx = 0 (no flow across the divide)
At x = 0: qx = −RL/2 + K(h₁²−h₂²)/2L   (flow drains left, toward h₁)
At x = L: qx = RL/2 + K(h₁²−h₂²)/2L   (flow drains right, toward h₂)

Special Case — Tile Drain (h₁ = h₂ = 0)

When two parallel drains sit at the same level (h₁ = h₂ = 0, measured from the drain level), the mound is symmetric:

hm L

Tile drains at equal level — the mound peaks midway between drains, at height hm.

h2=RK(Lx−x2)

For maximum h, dh²/dx = 0 ⇒ (R/K)(L−2x) = 0 ⇒ x = L/2:

hm2=RKL·L2−L24=RL24K
Design check: hm < (Z−Z0), the root-zone depth, so that water logging does not occur at the mound.

Well Hydraulics — Steady Radial Flow

Case 1 — Confined Flow Through a Fully Penetrating Well

Confined aquifer Q H hw r₁ r₂ rw R

Cone of depression around a fully penetrating well in a confined aquifer — potentiometric surface rises from hw at the well (rw) to H at the radius of influence (R).

Q=2πKD(h2−h1)lne(r2/r1)

Thiem's equation (confined).

Q=2πKD(H−hw)lne(R/rw)

Same equation applied at the well itself (R = radius of influence, rw = well radius, H−hw = drawdown in the well).

R — radius of influence; rw — radius of the well; H−hw — drawdown in the well

Case 2 — Unconfined Flow Through a Fully Penetrating Well

Q H hw r₁ r₂ R

Unconfined well — the water table cone of depression rises from hw at the well to H at the radius of influence R.

Q=πK(h22−h12)loge(r2/r1)

Thiem's equation (unconfined).

Q=πK(H2−hw2)loge(R/rw)

Dupuit's equation (unconfined).

Non-Equilibrium (Theis) Method

The steady state used above is established only after a sufficiently long time, when the drawdown/water table becomes constant. Practically, steady state is rarely reached quickly, so for unsteady conditions in a confined aquifer we use the non-equilibrium formula:

s=Q4πTln4Ttr2S−0.5772
s — drawdown at time t in the observation well
Q — discharge from the main well
T — coefficient of transmissibility
r — radial distance of the observation well from the main well
S — storage coefficient

If, in an observation well at radius r, the drawdowns at times t₁ and t₂ are s₁ and s₂:

s2−s1=Q4πTln(t2/t1)

If drawdowns in two observation wells, at r₁ and r₂, are the same at times t₁ and t₂ respectively (i.e. the argument of the log term is unchanged, so t/r² is constant):

t1r12=t2r22
Worked Example — Pumping Time for Equal Drawdown

In an artesian aquifer, drawdown is 1.2 m at a radial distance of 10 m from the pumping well after two hours of pumping. Determine the pumping time required for the same drawdown at a radial distance of 30 m.

Since the drawdown is the same, t/r² is constant (from the non-equilibrium formula):

t1r12=t2r22⇒2102=t2302

t₂ = 18 hours

Well Losses, Specific Capacity & Recuperation Test

Well Losses

The total drawdown (loss) in the well is thought to be due to: (a) drawdown required to cause water to flow from the aquifer to the well, and (b) drawdown required for flow through the well itself.

s1=CQ s2=C′Q2
s1 = CQ — formation loss (laminar aquifer-to-well flow)
s2 = C′Q² — well loss, due to turbulent flow in the well/pipe, so drawdown ∝ Q² (analogous to pipe friction loss hL = 4fLV²/(2gD), where hL ∝ Q²)
s=s1+s2=CQ+C′Q2

Specific Capacity

Specific capacity is the discharge from the well per unit drawdown in the well:

Specific capacity=Qs=QCQ+C′Q2=1C+C′Q

Specific capacity is thus, strictly, a function of discharge. However, we generally neglect the well-loss (second) term and assume specific capacity to be constant.

Recuperation Test

Done to calculate the specific capacity; this method is adopted because it is difficult to obtain steady-state conditions in the field.

Q=Cs Q=C′As
C — specific capacity, m³/s per m of drawdown
C′ — specific capacity per unit area, (m³/s)/m/m²
A — area of cross-section of the well
static level s₁ s₂ water level recuperates from s₁ to s₂ over time t

Recuperation test — after pumping stops, the depressed level s₁ recovers toward the static level, reaching s₂ after time t.

For a rise ds in level, Qdt = −Ads. Substituting Q = C′As:

C′As·dt=−Ads⇒C′dt=−dss

Integrating from 0 to t (s = s₁ to s = s₂):

C′t=−(lns2−lns1)=lns1s2
C′=ln(s1/s2)t
Worked Example — Well Diameter From a Recuperation Test

During a recuperation test, the water level in an open well was depressed by pumping by 2.5 m, and it recuperated by 1.6 m in 70 minutes. Determine the diameter of the well needed to yield 10 L/s under a depression head of 2.5 m.

s₁ = 2.5 m, s₂ = 2.5 − 1.6 = 0.9 m, t = 70 min = 4200 s:

C′=ln(2.5/0.9)4200

C′ = 2.432 × 10⁻⁴ (m³/s)/m²/m

Using Q = C′As with A = (π/4)d²:

10×10−3=2.432×10−4×π4d2×2.5

d = 4.575 m