Hydrology / Ground Water Hydrology
Below ground level, moisture occurs as hygroscopic water (adsorbed on soil particle surfaces), capillary water (held by surface tension), and gravitational water (free to drain under gravity). The vertical profile is divided as follows.
Vertical zonation of subsurface water: hygroscopic/capillary/gravitational water at the surface, the vadose zone (zone of aeration) above the capillary fringe, and the zone of saturation below the water table, where pore-water pressure increases linearly with depth (arrow length ∞ pressure).
The various water-bearing strata below the ground water table are classified on the basis of how easily water can be pumped out of them.
| Term | Behaviour | Example |
|---|---|---|
| Aquifer | Contains a lot of water and yields it easily due to high permeability | Coarse sand layer / gravel layer |
| Aquitard | Only seepage is possible through this layer; yield is insignificant | Sandy clay layer |
| Aquiclude | Highly porous but not permeable | Clay layer |
| Aquifuge | Neither porous nor permeable | Rocky layer |
Unconfined (water-table / phreatic) aquifer above an aquiclude, overlying a confined (artesian) aquifer whose potentiometric surface rises above the local water table; a perched aquifer sits on an isolated clay lens within the vadose zone.
In an unconfined aquifer, the water table fluctuates freely due to addition or withdrawal of water. In the confined aquifer, if the potentiometric surface falls (because of pumping), the effective stress in the soil increases and the soil gets compressed.
An aquifer performs two functions: (1) storage of water, and (2) transmission of the stored water.
A unit volume of saturated soil, Vsoil, drains a volume Vdrained under gravity and retains a volume Vretained against it.
In the case of a confined aquifer, the volume of water yielded by unit plan area of the aquifer, when the potentiometric surface falls by unity, is called the storage coefficient (S).
Confined aquifer of thickness D — the storage coefficient S is the volume released per unit plan area for a unit drop in the potentiometric surface.
The volume of water released from unit volume of aquifer due to unit drop in potentiometric surface is called specific storage (Ss).
From Darcy's law, for a confined aquifer of thickness D and unit width:
Storage coefficient and coefficient of transmissibility are important aquifer parameters, determined by carrying out a well pumping test.
Confined aquifer of thickness D connecting two water bodies at heads h₁ and h₂ — the piezometric head varies linearly (straight-line) with distance x.
Separating variables and integrating from 0 to x (h = h₁ at x = 0):
A straight-line variation of h with x.
At x = L, h = h₂, so qL = KD(h₁−h₂). Combining with the general result:
Unconfined aquifer between two water bodies — the water table follows a parabolic (Dupuit) curve, falling monotonically from h₁ to h₂.
A parabolic variation of h with x.
At x = L, h = h₂:
Uniform recharge R (m³/m·s) infiltrates over the whole strip. The hydraulic gradient is assumed constant throughout the depth.
Recharge raises the water table into a mound whose peak (the ground water divide, x = a) lies between the two reservoirs; on either side flow drains toward h₁ and h₂ respectively.
Consider a strip of width dx: inflow q, outflow q+dq, with dq = R·dx, so dq/dx = R. Using q = K(−dh/dx)(h×1) = −(K/2)·d(h²)/dx:
Integrating twice and applying h = h₁ at x = 0 and h = h₂ at x = L gives the general solution:
The flow at any section, qx = −(K/2)·d(h²)/dx, works out to:
The ground water divide is the highest point of the water table, located where dh/dx = 0, i.e. qx = 0 at x = a:
When two parallel drains sit at the same level (h₁ = h₂ = 0, measured from the drain level), the mound is symmetric:
Tile drains at equal level — the mound peaks midway between drains, at height hm.
For maximum h, dh²/dx = 0 ⇒ (R/K)(L−2x) = 0 ⇒ x = L/2:
Cone of depression around a fully penetrating well in a confined aquifer — potentiometric surface rises from hw at the well (rw) to H at the radius of influence (R).
Thiem's equation (confined).
Same equation applied at the well itself (R = radius of influence, rw = well radius, H−hw = drawdown in the well).
Unconfined well — the water table cone of depression rises from hw at the well to H at the radius of influence R.
Thiem's equation (unconfined).
Dupuit's equation (unconfined).
The steady state used above is established only after a sufficiently long time, when the drawdown/water table becomes constant. Practically, steady state is rarely reached quickly, so for unsteady conditions in a confined aquifer we use the non-equilibrium formula:
If, in an observation well at radius r, the drawdowns at times t₁ and t₂ are s₁ and s₂:
If drawdowns in two observation wells, at r₁ and r₂, are the same at times t₁ and t₂ respectively (i.e. the argument of the log term is unchanged, so t/r² is constant):
In an artesian aquifer, drawdown is 1.2 m at a radial distance of 10 m from the pumping well after two hours of pumping. Determine the pumping time required for the same drawdown at a radial distance of 30 m.
Since the drawdown is the same, t/r² is constant (from the non-equilibrium formula):
t₂ = 18 hours
The total drawdown (loss) in the well is thought to be due to: (a) drawdown required to cause water to flow from the aquifer to the well, and (b) drawdown required for flow through the well itself.
Specific capacity is the discharge from the well per unit drawdown in the well:
Specific capacity is thus, strictly, a function of discharge. However, we generally neglect the well-loss (second) term and assume specific capacity to be constant.
Done to calculate the specific capacity; this method is adopted because it is difficult to obtain steady-state conditions in the field.
Recuperation test — after pumping stops, the depressed level s₁ recovers toward the static level, reaching s₂ after time t.
For a rise ds in level, Qdt = −Ads. Substituting Q = C′As:
Integrating from 0 to t (s = s₁ to s = s₂):
During a recuperation test, the water level in an open well was depressed by pumping by 2.5 m, and it recuperated by 1.6 m in 70 minutes. Determine the diameter of the well needed to yield 10 L/s under a depression head of 2.5 m.
s₁ = 2.5 m, s₂ = 2.5 − 1.6 = 0.9 m, t = 70 min = 4200 s:
C′ = 2.432 × 10⁻⁴ (m³/s)/m²/m
Using Q = C′As with A = (π/4)d²:
d = 4.575 m