Hydrology / Irrigation / Part 2

Irrigation Engineering — Part 2

Converted from handwritten notes — Irrigation 02.pdf, pages 22–41 of 167 — Part 2 of 8

Doc No.IRR-02
StatusDraft — Awaiting Review
Converted28-07-2026
Approved—

Water Requirement of Crops

Water requirement of a crop is the total water needed by it from the time it is sown to the time it is harvested.

Note Depending on climate, type of soil, method of cultivation, rainfall etc., water requirement will vary with the crop as well as from place to place.
1st watering Sowing Last watering Harvesting Base period Crop period

Base period runs from the first watering (before sowing) to the last watering (before harvesting); crop period runs from sowing to harvesting.

Note In reality, crop period is greater than base period (crop period comes after base period), but theoretically both values are taken as the same, and even these terms are used interchangeably.

Duty and Delta

Delta (Δ)

Delta is defined as the total depth of water (in cm) required for a crop during the crop period.

Worked Example

If wheat requires 7 cm of water after every 25 days, base period of wheat is 125 days. Determine delta for wheat.

nos. of waterings=base periodfrequency=12525=5 Δ=7×5=35 cm

Duty (D)

Duty is the relationship between the volume of water available to irrigate an area for a particular crop. Duty is defined as the area irrigated in hectares by 1 cumec (1 m³/s) of water flowing continuously for the entire duration of the crop period, expressed as D = 300 ha/cumec (typical value).

By knowing the duty of water and the area of land to be irrigated for growing a particular crop, the discharge can be calculated.

Note In case of a canal, duty is called flow duty or duty. In case of storage irrigation (tanks or reservoirs), the area of land that can be irrigated by 1 million cubic metre (1×10&sup6; m³) of water stored in the tank or reservoir is called quantity duty or storage duty. In case of a well, water required by the well annually to bring the crop up to its maturity is called duty of well.

Relationship Between Duty and Delta

Let D ha of land be irrigated by supplying 1 m³/s of water for the entire base period = B (days), such that the total water stored in the root zone is delta (Δ).

Volume of water supplied=B days ×1 m³/s =B×24×3600 s ×1 m³/s=B·8.64×104 m³
Volume of water stored in root zone (in field, for whole base period B days)=D·Δ×104 m³

Equating the two volumes:

D·Δ×104=8.64×104×B ⇒D·Δ=8.64B
Δ — depth of water stored in root zone (in m)
B — base period, in days
D — duty, in ha/cumec
Worked Example

Find the Δ for a crop if duty for a base period of 120 days is 1500 ha/cumec.

Δ=8.64BD=8.64×1201500

Δ = 0.6912 m

Worked Example

A crop requires 900 mm of water for entire base period of 120 days. Find the duty of water.

D=8.64BΔ=8.64×1200.9

D = 1152 ha/cumec

Worked Example

A canal was designed to supply the irrigation needs of 1000 ha of land, growing rice of 140 days base period and having Delta of 130 cm. If the canal water is used to irrigate wheat of base period 119 days and having a Delta of 50 cm, determine the area which can be irrigated. Also determine the discharge required in the water course.

Method 1

1000×104×1.3=140×Q×8.64×104⇒Q=1.0747 m³/s Awheat×104×0.5=119×1.0747×8.64×104

Awheat = 2210 ha

Method 2

DR=8.64×BRΔR=8.64×1401.3=930.46 ha/cumec 930.46 ha ↔ 1 m³/s⇒1000 ha ↔1000930.46=1.0747 m³/s Dw=8.64×BwΔw=8.64×1190.5 ha/cumec Aw=Dw×discharge=8.64×1190.5×1.0747

Aw = 2210 ha

Factors Affecting Duty of Water

  1. Types of crop — lower duty for the crops requiring a large quantity of water.
  2. Climatic conditions
    • Temperature ↑ → evaporation ↑ → Duty ↓
    • Wind — wind velocity ↑ → evaporation ↑ → Duty ↓
    • Humidity ↑ → evaporation ↓ → Duty ↑
    • Rainfall ↑ → Duty ↑
  3. Method of irrigation — a method in which the losses are higher will have lower duty.
  4. Quality of water — if the quality of water is poor, duty will be less.
    Note If irrigation water contains an appreciable amount of harmful salts and alkalies dissolved in it, then it is required to be applied in large quantity such that salts are leached off, and hence duty reduces.
  5. Type of soil through which canal passes — if the canal is unlined and passes through coarse-grained soil, seepage losses will be more and duty will be less.
  6. Topography — if the land is levelled, then duty will be more.

Duty at Various Places

As water flows from river/reservoir to the field, duty of the canal varies from place to place, due to loss of water in transit (between the head of the canal system and the field, by percolation and evaporation).

River Weir / Barrage Gross duty Main Canal Branch Canal Lateral duty Distributary Canal Minor Canal Outlet discharge duty Watercourse / Field Channel Net quantity duty Field

Duty is measured at successively later points along the conveyance chain — gross duty at the main canal, lateral duty at the distributary, outlet discharge duty at the minor canal outlet, and net (quantity) duty at the field.

Worked Example

Loss in canal = 20%. Qfield = 100 m³/s. Find Qcanal.

Qcanal=1000.8=125 m³/s

If duty at the field is 1000 ha/cumec and 0.25 m³/s is lost during transit from main canal to field, therefore duty at the head of the main canal will be:

10001.25=800 ha

Duty increases from main canal to field.

Note If the place where duty is measured is not mentioned, then it should be assumed as net duty.

Crop Seasons & Crops of India

SeasonPeriodExamples
Kharif crops (summer crops)April to SeptemberRice, juwar, bajra, maize, groundnut
Rabi crops (winter crops)October to MarchWheat, barley, gram, mustard, potato
Perennial crops300–360 daysSugarcane
Zaid cropsMarch to JuneFruits and vegetables

Important Definitions

Crop Ratio / Rabi–Kharif Ratio (≈ 2)

crop ratio=area irrigated in rabi seasonarea irrigated in kharif season

Paleo Irrigation

It is defined as the watering done prior to the sowing of crops. It is done to make the land suitable for sowing as it becomes very dry, and to add sufficient moisture to the soil, which would be required for initial growth.

KOR Watering, KOR Period, KOR Depth

KOR watering is the first watering after the sowing of a crop, when the crop is a few cm high. This irrigation depth is the maximum of all the waterings, and this depth of water is called KOR depth. The portion of base period in which KOR watering is done is called KOR period.

Note KOR watering is used to find out the maximum discharge requirement, or peak discharge requirement, in the field.

GCA, CCA & Related Terms

Gross Command Area (GCA)

It is the total area within the limit of an irrigation project. This includes cultivable and non-cultivable area, ex. roads, lakes, buildings etc.

Capacity Factor

capacity factor=mean supply discharge of a canal for a certain durationmaximum discharge capacity

Planning of the irrigation system should be done in such a way that the capacity factor throughout the year remains close to unity.

Crop Calendar

Crop calendar is a tool that provides information about planting, sowing and harvesting periods of locally adopted crops in an area.

Transpiration Ratio

transpiration ratio=amount of water transpired by the plant during the crop seasonwt. of dry matter produced

Cultivable Command Area (CCA)

It is that portion of GCA which can be used for agricultural purposes, and it denotes the actual area in which irrigation has to be supplied.

Intensity of Irrigation

It is that % of CCA which is proposed to be irrigated in a given season.

Irrigation Efficiencies

irrigation efficiency=water available for usewater applied

(a) Water Conveyance Efficiency

ηc=WfWR×100
WR — water released from reservoir or river
Wf — water given to the field

This efficiency accounts for water losses such as seepage and evaporation, which occur during conveyance from the river/reservoir to the field.

Worked Example

The Gross Command Area of an irrigation canal is 20000 ha, of which 75% is CCA. The intensity of irrigation is 40% for Rabi crops, 10% for rice. Crop period is 4 weeks for Rabi crops and 2.5 weeks for rice. Determine the outlet discharge, outlet factor for Rabi and rice. May be assumed as 1800 ha/cumec and 775 ha/cumec. Also calculate Δ for each case.

CCA=75100×20000=15000 ha Rabi area=40100×15000=6000 ha Rice area=10100×15000=1500 ha
Drabi = 1800 ha/cumec (given)
Drice = 775 ha/cumec (given)
Discharge for rabi=60001800=3.333 m³/s Discharge for rice=1500775=1.935 m³/s
Δrabi=8.64×7×41800=0.1344 m=13.44 cm Δrice=8.64×2.5×7775=0.195 m=19.5 cm

Max discharge in canal = 3.333 m³/s

(b) Water Application Efficiency

ηa=WsWf×100
Wf — water given to the field
Ws — water stored in the field (root zone)
Wf=Ws+Runoff+Deep percolation=Ws+Rf+Df

This efficiency accounts for losses such as surface runoff (Rf) and deep percolation (Df), which occur during the application of irrigation water in the field.

Since Ws=Wf−Rf−Df,  ηa=Wf−Rf−DfWf×100

(c) Water Use Efficiency

ηu=WuWf×100
Wu — water used consumptively
Wf — water given to the field
Wu — water required for leaching, water stored + pre-sowing requirement

(d) Water Storage Efficiency

ηs=WsWn×100
Ws — water stored in the root zone
Wn — water needed to be stored to bring up to field capacity
Wn=field capacity−moisture available in soil prior to irrigation

(e) Water Distribution Efficiency (Uniformity Coefficient)

ηd=1−yd×100
d — average depth of water stored in root zone
y — average numerical deviation in the depth of water stored from the average depth

It takes into account the degree to which water is uniformly distributed in the root zone throughout the field area, hence this efficiency is also called uniform coefficient.

Note Higher the value of ηd, more uniformly water is distributed in the root zone, which results in better crop response.

Worked Examples

Worked Example

A water course commands an irrigated area of 1000 ha. The intensity of irrigation of rice in this area = 70%. The transplantation of rice crop takes 15 days, and during this transplantation period, total depth of water required by the crop in the field is 500 mm. During this period the useful rain falling in the field is 120 mm. Find the duty of irrigation water for the crop on the field for the transplantation period, at the head of field and at the head of watercourse, assuming 20% loss in the watercourse. Also determine the discharge required in the watercourse.

CCA=1000 ha,  intensity=70%⇒irrigated area (rice)=700 ha Net water required by rice during transplantation=500−120=380 mm

In field, Df·Δ = 8.64B:

Df=8.64×150.380=341.05 ha/cumec

At the head of watercourse (20% loss):

DWC=0.8×341.05=272.84 ha/cumec QWC=700272.84=2.565 m³/s
Worked Example

The table below gives necessary data about crop, duty of water and area under each crop, commanded by a canal taking off from a storage reservoir. Determine the reservoir capacity if CCA is 40000 ha, canal losses are 20% and reservoir losses are 10%.

CropBase period (days)Duty (ha/cumec)Intensity of irrigation
Wheat (Rabi)120180020%
Sugarcane (Perennial)360170020%
Cotton (Rabi)180140010%
Rice (Kharif)12080015%
Vegetable12070015%

CCA = 40000 ha, canal loss = 20%, reservoir loss = 10%.

Area (ha) = intensity % × CCA; Δ (m) = 8.64B/D; Volume (ha-m) = Area × Δ; Discharge required (m³/s) = Volume / (B × 8.64):

CropArea (ha)Δ (m)Volume (ha-m)Discharge req. (m³/s)
Wheat80000.57646084.444
Sugarcane80001.83146404.706
Cotton40001.1144442.837
Rice60001.29677767.5
Vegetable60001.48188868.531

Total volume = 4608 + 14640 + 4444 + 7776 + 8886 = 40354 ha-m.

Rabi crops = Wheat + Cotton; Kharif crops = Rice; Perennial crops = Sugarcane (Vegetable spans both seasons).

Discharge for rabi season in canal=Qwheat+Qcotton+Qsugarcane+Qvegetable=20.58 m³/s Discharge for kharif season in canal=Qrice+Qsugarcane+Qvegetable=20.77 m³/s

Actual discharge required in the canal (20% canal loss):

Kharif=20.7760.8=25.97 m³/s Rabi=20.580.8=25.725 m³/s

Hence, canal will be designed for the greater discharge ⇒ 25.97 m³/s.

Water should be stored in the reservoir to cover the whole year's requirement (40354 ha-m), accounting for both reservoir loss (10%) and canal loss (20%):

actual water stored in reservoir=403540.9×0.8

Reservoir capacity = 56047.22 ha-m