Hydrology / Discharge Measurement
Review copy — each diagram below is shown next to your original handwritten page. Remove all "Your original" panels before publishing.
Water flowing in a stream is stream flow. If it's unaffected by artificial diversion or storage upstream, it's called runoff or virgin stream flow.
Measuring a natural stream's discharge directly is difficult, so instead we establish a stage-discharge relationship — once that relationship is known, measuring stage alone tells us the discharge.
Your original — page 1
Stage: water surface elevation above an assumed datum (usually MSL).
Your original — page 1
Stage-discharge relationship (illustrative).
Your original — page 2
Stage hydrograph (illustrative — rises faster than it recedes).
Velocity is generally measured with a current meter; it can be roughly estimated using floats.
Your original — page 2
Velocity profile with standard current-meter measurement depths (0.2H, 0.6H, 0.8H measured from the free surface).
N = revolutions per second; a, b from towing-tank calibration
The stream cross-section is divided into vertical segments at measurement stations. Each segment's discharge is its average width × depth × velocity; total discharge is the sum.
Your original — page 4
Cross-section drawn to the actual depths from the worked example below — y1–y8 = 0.4, 0.8, 1.2, 2.0, 3.0, 2.5, 2.2, 1.0 m at stations 3–24 m. Each depth line runs exactly to the riverbed.
the end segment is triangular — area = ½ ⋅ base ⋅ height = ½ y1 w1 — divided by its representative width w1,avg = w1 + w2/2, times velocity
→ this coefficient of y1·V1 is exactly the "avg width" used below
End segment Intermediate segment i DischargeQ. Using the equation Vm/s = 0.65N + 0.03, where N is rev/sec for the current meter and the avg velocity is calculated by single point observation, compute the discharge through a river section. The current meter observations are as given below.
| Dist. from bank (m) | Depth y (m) | Revolutions | Time (s) | N (rev/s) | V (m/s) | Avg width (m) | Qᵢ (m³/s) |
|---|---|---|---|---|---|---|---|
| 3 | 0.40 | 30 | 150 | 0.200 | 0.160 | 3.375 | 0.216 |
| 6 | 0.80 | 50 | 130 | 0.385 | 0.280 | 3.000 | 0.672 |
| 9 | 1.20 | 70 | 100 | 0.700 | 0.485 | 3.000 | 1.746 |
| 12 | 2.00 | 100 | 80 | 1.250 | 0.843 | 3.000 | 5.055 |
| 15 | 3.00 | 150 | 60 | 2.500 | 1.655 | 3.000 | 14.895 |
| 18 | 2.50 | 200 | 50 | 4.000 | 2.630 | 3.000 | 19.725 |
| 21 | 2.20 | 130 | 40 | 3.250 | 2.143 | 3.000 | 14.140 |
| 24 | 1.00 | 90 | 130 | 0.692 | 0.480 | 3.375 | 1.620 |
| Total discharge Q | 58.07 m³/s | ||||||
Using V = 0.65N + 0.03 (given calibration equation), single-point (0.6H) velocity method.
A boat crosses the stream while moving; the current meter records a resultant velocity VR at angle θ to the boat's heading. Decomposing VR recovers both the flow velocity and the boat's own speed.
Your original — page 6
Velocity triangle: V_R measured directly, V_f and V_b recovered by decomposition.
Your original — page 6
The boat crosses along the same subdivided cross-section as the area-velocity method — each vertical still records its own depth y and the resultant velocity V_R at that station.
substituting the moving-boat measurements wi+1 = VRcosθ·Δt (distance covered between readings) and Vi+1 = VRsinθ (flow velocity component):
A stable or radioactive tracer (e.g. common salt, sodium dichromate) is injected upstream; discharge is inferred from how much it's diluted by the time it reaches a downstream section.
Your original — page 7 (approx.)
Tracer added at point 1; concentration is monitored downstream at point 2.
Your original — page 7 (approx.)
Shaded area = ∫(C2 − C0) dt, the denominator of the discharge formula.
Concentration C1 and volume V1 is added at section 1, all at once. Concentration at section 2 was noted at various times; initial concentration of the chemical is C0. Hence,
Note: volume of chemical relative to volume of water is neglected — i.e. is treated as negligible.
Your original — page 8
Concentration at the downstream section rises until it holds steady at plateau value C2.
→ solve for Q
Qt = tracer injection discharge
Two transducers face each other diagonally across the channel. A pulse sent with the flow arrives faster than one sent against it — the difference gives the flow velocity directly.
Your original — page 9
Diagonal transducer pair; pulse transit times t1 (downstream) and t2 (upstream) yield flow velocity.