Hydrology / Abstraction from Precipitation

Abstraction from Precipitation

Converted from handwritten notes — Hydrology 03 Abstraction from Precipitation.pdf, 24 pages

Doc No.HYD-03
StatusDraft — Awaiting Review
Converted10-08-2026
Approved—

Abstraction from Precipitation

Rainfall−Runoff=Abstraction from PPT

In engineering hydrology, our basic aim is to calculate runoff. That part of rainfall which is not converted into runoff is called abstraction from precipitation. It will be in the form of:

  1. Evaporation
  2. Transpiration
  3. Interception
  4. Depression storage
  5. Infiltration

Evaporation

It is the conversion of water from the liquid phase to the gaseous phase. Evaporation rate depends on:

  1. Vapour pressure
  2. Temperature
  3. Wind
  4. Pressure
  5. Water quality
  6. Depth of water body
  7. Shape and size of water body

Vapour Pressure — Dalton's Law

EL=Cew−ea
EL — rate of evaporation, in mm/day
ew — saturation vapour pressure, in mm of Hg
ea — actual vapour pressure, in mm of Hg
C — empirical constant

Temperature

Other factors remaining constant, if temperature increases, evaporation increases.

Wind

vapour blanket W vapour shifts with wind

Left: still air — a vapour blanket builds above the water surface, limiting further evaporation. Right: wind W sweeps the vapour blanket away, exposing fresh dry air and sustaining a higher evaporation rate.

As wind speed increases, evaporation increases; but beyond a particular wind speed, evaporation becomes constant. High wind speed will blow away the evaporated water, causing a deficiency of vapour above the water body — hence the rate of evaporation will increase.

Pressure

As pressure decreases, evaporation increases.

Water Quality

Evaporation rate is less in saline water as compared to fresh water of a lake (E ↑ for distilled water, E ↓ for saline water).

Depth of Water Body

Summer shallow water body Winter heat deeper water body

In a shallow water body, maximum evaporation occurs in summer; in a deeper water body, maximum evaporation occurs in winter — because of heat stored in the deep water body carrying over from summer.

Shape and Size of Water Body

E ↑ pan w shifted blanket vapour blanket w lake

If the water body is large (lake), the vapour blanket covers a wide area, and a very large wind velocity is required to remove it — reducing evaporation. In a small water body (pan), even a small wind speed carries away the evaporated water, so the pan cannot affect the humidity of the air above it. Hence small water bodies show more evaporation than large ones.

Measurement of Evaporation

Evaporation is measured by:

  1. Evaporimeter
  2. Empirical evaporation equation
  3. Analytical method

(A) Evaporimeter

Lake evaporation=Cp×pan evaporation

For an ISI pan (Indian Standard Index), Cp = 0.8 (pan coefficient).

(B) Empirical Equations — Meyer's Formula

EL=Kmew−ea1+U916
EL — rate of evaporation, in mm/day
ew — saturation vapour pressure, in mm of Hg
ea — actual vapour pressure, in mm of Hg
U9 — average monthly wind velocity at 9 m height above ground surface, in km/h
Km — Meyer's constant — 0.36 for large, deep water bodies; 0.5 for small, shallow water bodies

If ea is given in Pa (P), convert to mm of Hg via P/γHg. If wind velocity is given at a height other than 9 m, use Uh = Ch1/7 (C = constant); if U10 is given:

U9U10=91/7101/7

(C) Analytical Method

  1. Water budget equation
  2. Energy balance method
  3. Mass transfer method

(i) Water budget equation — the least reliable of the three. Here we use the continuity equation, called the water budget equation:

P−R−E−T−G=S

If the terms in the continuity equation, except evaporation, are known, then E can be calculated.

(ii) Energy balance method (not an empirical equation):

HL=ρLEL
HL — heat required for evaporation, in J/sec
ρ — density, in kg/m³
L — latent heat of evaporation, in J/kg
EL — rate of evaporation, in m³/s
Hs Hn Ha Hg Hi S L latent heat Energy →

Energy balance on a water body — Hn = Hi + Ha + Hg + Hs + HL.

Hn — net heat received by the water surface
Ha — heat transferred from water to air
Hg — heat going into the ground
Hs — heat stored in the water body
Hi — heat carried away from the lake in the form of surface water outflow
HL — heat required for evaporation

With other terms known, HL can be easily calculated.

(iii) Mass transfer method — based on the theory of turbulent mass transfer in the boundary layer.

Reduction in Lake Evaporation

The following procedures are adopted:

  1. Reducing the surface area of the reservoir or lake by making a deeper water body.
  2. By using a mechanical cover.
  3. By using a chemical film. Chemicals used are: (a) cetyl alcohol (hexadecanol), (b) stearyl alcohol (octadecanol).

Evapotranspiration

Evapotranspiration — combined loss of water from soil (evaporation) and vegetation (transpiration).

Transpiration is the process by which water vapour escapes from a living plant into the atmosphere. It is difficult to estimate the loss of water from the surface to the atmosphere separately in terms of evaporation and transpiration; hence the two processes are studied together, and are combinedly called evapotranspiration, or consumptive use.

When sufficient moisture is always available to completely meet the need of vegetation, ET will occur at the maximum rate, called PET (Potential Evapotranspiration). When soil moisture is at field capacity, ET is at PET. When soil moisture is less than field capacity, ET will occur at AET (Actual Evapotranspiration). The ratio AET/PET depends on the type of soil and rate of drying.

Note In the case of clayey soil, AET/PET = 1 even up to 50% of available moisture. In the case of sandy soil, however, AET/PET would be less than 1 at moisture content less than field capacity.
Available moisture=Field capacity−Permanent wilting point

AET/PET ∈ (0, 1).

Measurement of AET

Two methods are used: (a) lysimeter, (b) field plot.

Lysimeter — consists of a circular tank filled with soil and an individual crop for which evapotranspiration is to be measured. The circular tank is buried into the ground, and AET is calculated as:

AET=Wsi+Wad−Wc−Wsf
Wsi — original weight of container + soil + plant
Wad — weight of water added
Wc — weight of water collected
Wsf — final weight of container + soil + plant

Field plot:

(stored) AET inflow (irrigation/PPT) outflow (surface runoff)

Field-plot water balance — the field is treated as a control volume.

AET=Inflow−Outflow−Storage

Measurement of PET

PET is measured using: (a) Penman's equation, (b) Blaney–Criddle formula.

Penman's equation — used to measure PET. It is based on the concept of energy balance and the mass transfer approach.

Blaney–Criddle formula — an empirical formula used for measuring PET:

PET=2.54KΣPfTf100
Pf — monthly % of annual daylight hours
Tf — mean monthly temperature, in °F
PET — potential evapotranspiration, in cm, for a crop period
K — constant depending on the type of crop, month, and locality

°C to °F conversion: F° = 1.8(C°) + 32.

Worked Example

Estimate the PET of an area for the season Nov to Feb, in which wheat is grown. The monthly mean temperature and monthly % of annual daylight hours are as given below. Take K = 0.65. Use the Blaney–Criddle formula.

MonthNovDecJanFeb
T (°C)16.5131114.5
Monthly % of daylight hr (Pf)7.197.157.307.03
T (°F)61.755.451.858.1

ΣPfTf = 7.19×61.7 + 7.15×55.4 + 7.30×51.8 + 7.03×58.1 = 1626.32:

PET=2.54×0.65×1626.32100

PET = 26.85 cm

Interception, Depression Storage, and Infiltration

Infiltration — the process by which precipitation moves into the surface of the soil.

interflow (subsurface runoff) ground water flow

Infiltrated water splits into interflow (subsurface runoff, shallow, faster) and deep percolation feeding groundwater flow.

Infiltration causes an increase in soil moisture content and recharges the aquifer. The recharged aquifer ultimately supports river flow during the dry season.

For a major storm, capable of producing flood, evaporation, transpiration, depression storage, and interception are neglected; thus we can write:

P−R=I
P — precipitation
R — runoff
I — infiltration

Interception and depression storage are also called initial losses.

Factors Affecting Infiltration

  1. Rainfall characteristics. Infiltration capacity (fc) is defined as the maximum rate at which rain can be abstracted by soil.
    P<fc  ⇒  I=P P>fc  ⇒  I=fc

    P — precipitation, I — actual infiltration.

  2. Rainfall intensity. Increase in rainfall intensity may lead to compaction of soil due to force exerted by falling raindrops. Hence, infiltration capacity (fc) ∝ 1/intensity of rainfall.
  3. Characteristics of soil. Sandy soil will have more infiltration.
  4. Vegetation cover. Tends to increase infiltration, because of retention of water and reduction in raindrop compaction.
  5. Viscosity of water. Increase in viscosity will lead to a decrease in infiltration.
  6. Temperature. Increased temperature will cause a decrease in viscosity, hence an increase in infiltration.

Measurement of Infiltration

We use two methods: (1) use of an infiltrometer, (2) by using rainfall simulation.

(1) Infiltrometer — of two types: (a) flooding type, (b) ring type.

Flooding type A₀ constant head = 5 cm Q / A₀ = I Ring type plan A₀ section

Flooding-type infiltrometer — a single ring with a constant 5 cm head; infiltration = Q/A₀. Ring-type infiltrometer — a water jacket (outer ring) prevents lateral spreading, so the inner ring's area A₀ represents the true area of vertical infiltration.

(2) Rainfall simulation:

Shower R P − R = I

Rainfall simulator — the water budget equation P − R = I is used to find infiltration.

This method simulates the rainfall characteristics, rainfall compaction, and turbid water created during rainfall. Rainfall simulators give a smaller value of infiltration as compared to an infiltrometer.

Infiltration Rate Using Empirical Equations

The various formulas used are:

  1. Green–Ampt model
  2. Horton's infiltration equation
  3. Huggins–Monke equation
  4. Antecedent PPT method

The most commonly used — Horton's Infiltration Equation:

f(t) t f₀ fc

Horton's infiltration curve — capacity decays from an initial value f₀ toward a constant ultimate value fc as the soil saturates.

ft=fc+f0−fce−αt
f(t) — infiltration capacity at any time t from the start of rainfall
f₀ — initial infiltration capacity
fc — ultimate infiltration capacity
α — constant

The initial infiltration rate is generally more, and as time passes, the rate decreases, ultimately achieving a constant value called the ultimate infiltration capacity. This infiltration capacity prevails when the soil becomes saturated.

intensity of rainfall (cm/hr) time (hr) t Horton's infiltration curve excess area → runoff Infiltration

Rainfall intensity bars vs. Horton's curve — area above the curve (excess rainfall) becomes runoff; area under the curve up to time t is the infiltration volume, I = ∫₀t ft·dt.

I=∫0tft·dt

If the rainfall excess only begins at t1 and ends at t2 (with area A representing the constant-rate infiltration before t1, and area B the portion under the Horton curve from t1 to t2):

I=area A+area B=area A+∫t1t2ft·dt
Worked Example

During a 3 hr storm, it was observed that all abstractions other than infiltration are negligible. The rainfall was observed as 3 nos. of 1 hr storms of intensities 10 mm/hr, 20 mm/hr, and 10 mm/hr respectively. The infiltration was idealized as a Horton's infiltration curve with f = 6.8 + 8.7e⁻t, where f is in mm/hr and t is in hr. Find out the effective rainfall.

Rainfall above infiltration is called effective rainfall; it is that part of rainfall which gets converted into runoff. In hour 1, intensity (10 mm/hr) < f(0) = 15.5 mm/hr, so the entire first hour infiltrates:

I=10×1+∫136.8+8.7e−tdt I=26.36 mm

Effective rainfall = runoff = P − I = 40 − 26.36:

Runoff = 13.64 mm

Infiltration Indices

In hydrological calculation, it is convenient to use the average infiltration rate for the duration of a storm. This constant average value of infiltration rate is called the infiltration index. Two infiltration indices are most commonly used: (a) φ-index, (b) w-index.

φ-Index

I (cm/hr) t (hr) φ-index (cm/hr) → infiltration + initial losses → runoff duration of rainfall excess

Horton's infiltration losses: the φ-index is the constant intensity line such that rainfall above it becomes runoff, and below it (plus the initial part before the line is reached) represents infiltration and initial losses.

φ-index=Rainfall−Runoffduration of rainfall excess

(Rainfall − Runoff) includes infiltration and initial losses; thus the φ-index includes initial losses also. Knowledge of the φ-index helps in calculating runoff produced by a particular storm.

Note Rainfall − Runoff = φt + area (±) — in general, φ = (P−R)/T is not valid; the simple formula above is valid only when duration of rainfall excess = duration of storm. Hence the φ-index is thought of as the rainfall intensity above which all intensity gets converted into runoff. For design purposes, in the absence of a computed φ-index value, we adopt φ-index = 0.1 cm/hr.

w-Index

w-index=Rainfall−Runoff−initial lossesduration of rainfall excess

φ ≥ w. The w-index accounts for infiltration only, and it is always less than or equal to the φ-index. Similarly, the w-index can be thought of as the rainfall intensity above which all intensity gets converted into either runoff or initial losses.

Worked Example

A 6 hr rain storm with hourly intensity of 7, 18, 25, 17, 11, and 3 mm/hr produces a runoff of 39 mm. Calculate the φ-index.

Sum of intensities = 7+18+25+17+11+3 = 81 mm:

φ=81−396=426=7 mm/hr

But at φ = 7 mm/hr, the hour with intensity 3 mm/hr (< 7) does not contribute to runoff, so it must be excluded and φ recomputed over the remaining hours (the 7 mm/hr hour is also then at/below the revised index and gets excluded in turn):

φnew=81−39−3−74=324=8 mm/hr

φ-index ≠ 7 mm/hr, since i = 3 mm/hr < 7 mm/hr; time of excess runoff = 5 hr; φ-index = 8 mm/hr

w-index, excluding the same non-contributing hours:

w-index=81−39−3−76=326=5.33 mm/hr
Worked Example

A storm with 10 cm PPT produces a direct runoff of 5.8 cm. The duration of the storm was 16 hr, and its time distribution is as given below. Find the φ-index.

Time since start (hr)0246810121416
Cumulative rainfall (cm)00.41.32.85.16.98.59.510.0

Breaking the cumulative record into individual 2 hr increments and dividing by 2 to get intensity:

t (hr)0246810121416
Cumulative I (cm)00.41.32.85.16.98.59.510.0
Individual I (cm)—0.40.91.52.31.81.61.00.5
Intensity (cm/hr)—0.20.450.751.150.90.80.50.25

First trial, over the full 16 hr duration:

φ=10−5.816=0.2625 cm/hr

At φ = 0.2625 cm/hr, the threshold per 2 hr interval is 0.525 cm. Two intervals fall below this — t = 0–2 hr (0.4 cm, intensity 0.2 cm/hr) and t = 14–16 hr (0.5 cm, intensity 0.25 cm/hr) — so they infiltrate in full and must be excluded from the rainfall-excess duration. Recomputing φ over the remaining 6 intervals (12 hr):

φ=10−5.8−0.4−0.56×2=3.312=0.275 cm/hr

Check: at φ = 0.275 cm/hr, the 2 hr threshold is 0.55 cm — still only the same two intervals (0.4 cm and 0.5 cm) fall below it, so the trial has converged.

φ-index = 0.275 cm/hr

Worked Example

An isolated 3 hr storm occurred over a basin in the following fashion (catchment split into three sub-areas of 20%, 30%, 50%, each with its own φ-index and hourly rainfall). Calculate the runoff depth from the catchment due to the storm.

% of catchment areaφ-index (cm/hr)
201
300.75
500.5
Area (%)1 hr (cm)2 hr (cm)3 hr (cm)
200.82.31.5
300.72.71.0
501.02.50.8

For each sub-area, runoff occurs only in the hours where rainfall exceeds that sub-area's φ-index, and the excess is (rainfall − φ) summed over those hours — for the 20% area (φ=1): only 2hr (2.3) and 3hr (1.5) exceed 1, giving excess (2.3−1)+(1.5−1) = 1.3+0.5 = 1.8; for the 30% area (φ=0.75): all three hours exceed 0.75, but the source's working uses only the 2 hr value (2.7−0.75≈1.6–1.95, shown as 1.6–1.95 range in-line); for the 50% area (φ=0.5): the 2 hr value (2.5) is used directly as 2.8−... Reproducing the source's own combined weighted-average calculation:

Runoff depth=201.3+0.5+301.6+502.8100
Handwriting note The middle two bracketed terms in the source's runoff-depth line (for the 30% and 50% sub-areas) are partly overwritten/corrected in the scan and not fully legible. The final boxed answer is reproduced as given below — Kishan, worth confirming the 30%/50%-area excess terms against your original page.

Runoff depth = 2.24 cm