Hydrology / Abstraction from Precipitation
In engineering hydrology, our basic aim is to calculate runoff. That part of rainfall which is not converted into runoff is called abstraction from precipitation. It will be in the form of:
It is the conversion of water from the liquid phase to the gaseous phase. Evaporation rate depends on:
Other factors remaining constant, if temperature increases, evaporation increases.
Left: still air — a vapour blanket builds above the water surface, limiting further evaporation. Right: wind W sweeps the vapour blanket away, exposing fresh dry air and sustaining a higher evaporation rate.
As wind speed increases, evaporation increases; but beyond a particular wind speed, evaporation becomes constant. High wind speed will blow away the evaporated water, causing a deficiency of vapour above the water body — hence the rate of evaporation will increase.
As pressure decreases, evaporation increases.
Evaporation rate is less in saline water as compared to fresh water of a lake (E ↑ for distilled water, E ↓ for saline water).
In a shallow water body, maximum evaporation occurs in summer; in a deeper water body, maximum evaporation occurs in winter — because of heat stored in the deep water body carrying over from summer.
If the water body is large (lake), the vapour blanket covers a wide area, and a very large wind velocity is required to remove it — reducing evaporation. In a small water body (pan), even a small wind speed carries away the evaporated water, so the pan cannot affect the humidity of the air above it. Hence small water bodies show more evaporation than large ones.
Evaporation is measured by:
For an ISI pan (Indian Standard Index), Cp = 0.8 (pan coefficient).
If ea is given in Pa (P), convert to mm of Hg via P/γHg. If wind velocity is given at a height other than 9 m, use Uh = Ch1/7 (C = constant); if U10 is given:
(i) Water budget equation — the least reliable of the three. Here we use the continuity equation, called the water budget equation:
If the terms in the continuity equation, except evaporation, are known, then E can be calculated.
(ii) Energy balance method (not an empirical equation):
Energy balance on a water body — Hn = Hi + Ha + Hg + Hs + HL.
With other terms known, HL can be easily calculated.
(iii) Mass transfer method — based on the theory of turbulent mass transfer in the boundary layer.
The following procedures are adopted:
Evapotranspiration — combined loss of water from soil (evaporation) and vegetation (transpiration).
Transpiration is the process by which water vapour escapes from a living plant into the atmosphere. It is difficult to estimate the loss of water from the surface to the atmosphere separately in terms of evaporation and transpiration; hence the two processes are studied together, and are combinedly called evapotranspiration, or consumptive use.
When sufficient moisture is always available to completely meet the need of vegetation, ET will occur at the maximum rate, called PET (Potential Evapotranspiration). When soil moisture is at field capacity, ET is at PET. When soil moisture is less than field capacity, ET will occur at AET (Actual Evapotranspiration). The ratio AET/PET depends on the type of soil and rate of drying.
AET/PET ∈ (0, 1).
Two methods are used: (a) lysimeter, (b) field plot.
Lysimeter — consists of a circular tank filled with soil and an individual crop for which evapotranspiration is to be measured. The circular tank is buried into the ground, and AET is calculated as:
Field plot:
Field-plot water balance — the field is treated as a control volume.
PET is measured using: (a) Penman's equation, (b) Blaney–Criddle formula.
Penman's equation — used to measure PET. It is based on the concept of energy balance and the mass transfer approach.
Blaney–Criddle formula — an empirical formula used for measuring PET:
°C to °F conversion: F° = 1.8(C°) + 32.
Estimate the PET of an area for the season Nov to Feb, in which wheat is grown. The monthly mean temperature and monthly % of annual daylight hours are as given below. Take K = 0.65. Use the Blaney–Criddle formula.
| Month | Nov | Dec | Jan | Feb |
|---|---|---|---|---|
| T (°C) | 16.5 | 13 | 11 | 14.5 |
| Monthly % of daylight hr (Pf) | 7.19 | 7.15 | 7.30 | 7.03 |
| T (°F) | 61.7 | 55.4 | 51.8 | 58.1 |
ΣPfTf = 7.19×61.7 + 7.15×55.4 + 7.30×51.8 + 7.03×58.1 = 1626.32:
PET = 26.85 cm
Infiltration — the process by which precipitation moves into the surface of the soil.
Infiltrated water splits into interflow (subsurface runoff, shallow, faster) and deep percolation feeding groundwater flow.
Infiltration causes an increase in soil moisture content and recharges the aquifer. The recharged aquifer ultimately supports river flow during the dry season.
For a major storm, capable of producing flood, evaporation, transpiration, depression storage, and interception are neglected; thus we can write:
Interception and depression storage are also called initial losses.
P — precipitation, I — actual infiltration.
We use two methods: (1) use of an infiltrometer, (2) by using rainfall simulation.
(1) Infiltrometer — of two types: (a) flooding type, (b) ring type.
Flooding-type infiltrometer — a single ring with a constant 5 cm head; infiltration = Q/A₀. Ring-type infiltrometer — a water jacket (outer ring) prevents lateral spreading, so the inner ring's area A₀ represents the true area of vertical infiltration.
(2) Rainfall simulation:
Rainfall simulator — the water budget equation P − R = I is used to find infiltration.
This method simulates the rainfall characteristics, rainfall compaction, and turbid water created during rainfall. Rainfall simulators give a smaller value of infiltration as compared to an infiltrometer.
The various formulas used are:
The most commonly used — Horton's Infiltration Equation:
Horton's infiltration curve — capacity decays from an initial value f₀ toward a constant ultimate value fc as the soil saturates.
The initial infiltration rate is generally more, and as time passes, the rate decreases, ultimately achieving a constant value called the ultimate infiltration capacity. This infiltration capacity prevails when the soil becomes saturated.
Rainfall intensity bars vs. Horton's curve — area above the curve (excess rainfall) becomes runoff; area under the curve up to time t is the infiltration volume, I = ∫₀t ft·dt.
If the rainfall excess only begins at t1 and ends at t2 (with area A representing the constant-rate infiltration before t1, and area B the portion under the Horton curve from t1 to t2):
During a 3 hr storm, it was observed that all abstractions other than infiltration are negligible. The rainfall was observed as 3 nos. of 1 hr storms of intensities 10 mm/hr, 20 mm/hr, and 10 mm/hr respectively. The infiltration was idealized as a Horton's infiltration curve with f = 6.8 + 8.7e⁻t, where f is in mm/hr and t is in hr. Find out the effective rainfall.
Rainfall above infiltration is called effective rainfall; it is that part of rainfall which gets converted into runoff. In hour 1, intensity (10 mm/hr) < f(0) = 15.5 mm/hr, so the entire first hour infiltrates:
Effective rainfall = runoff = P − I = 40 − 26.36:
Runoff = 13.64 mm
In hydrological calculation, it is convenient to use the average infiltration rate for the duration of a storm. This constant average value of infiltration rate is called the infiltration index. Two infiltration indices are most commonly used: (a) φ-index, (b) w-index.
Horton's infiltration losses: the φ-index is the constant intensity line such that rainfall above it becomes runoff, and below it (plus the initial part before the line is reached) represents infiltration and initial losses.
(Rainfall − Runoff) includes infiltration and initial losses; thus the φ-index includes initial losses also. Knowledge of the φ-index helps in calculating runoff produced by a particular storm.
φ ≥ w. The w-index accounts for infiltration only, and it is always less than or equal to the φ-index. Similarly, the w-index can be thought of as the rainfall intensity above which all intensity gets converted into either runoff or initial losses.
A 6 hr rain storm with hourly intensity of 7, 18, 25, 17, 11, and 3 mm/hr produces a runoff of 39 mm. Calculate the φ-index.
Sum of intensities = 7+18+25+17+11+3 = 81 mm:
But at φ = 7 mm/hr, the hour with intensity 3 mm/hr (< 7) does not contribute to runoff, so it must be excluded and φ recomputed over the remaining hours (the 7 mm/hr hour is also then at/below the revised index and gets excluded in turn):
φ-index ≠ 7 mm/hr, since i = 3 mm/hr < 7 mm/hr; time of excess runoff = 5 hr; φ-index = 8 mm/hr
w-index, excluding the same non-contributing hours:
A storm with 10 cm PPT produces a direct runoff of 5.8 cm. The duration of the storm was 16 hr, and its time distribution is as given below. Find the φ-index.
| Time since start (hr) | 0 | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 |
|---|---|---|---|---|---|---|---|---|---|
| Cumulative rainfall (cm) | 0 | 0.4 | 1.3 | 2.8 | 5.1 | 6.9 | 8.5 | 9.5 | 10.0 |
Breaking the cumulative record into individual 2 hr increments and dividing by 2 to get intensity:
| t (hr) | 0 | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 |
|---|---|---|---|---|---|---|---|---|---|
| Cumulative I (cm) | 0 | 0.4 | 1.3 | 2.8 | 5.1 | 6.9 | 8.5 | 9.5 | 10.0 |
| Individual I (cm) | — | 0.4 | 0.9 | 1.5 | 2.3 | 1.8 | 1.6 | 1.0 | 0.5 |
| Intensity (cm/hr) | — | 0.2 | 0.45 | 0.75 | 1.15 | 0.9 | 0.8 | 0.5 | 0.25 |
First trial, over the full 16 hr duration:
At φ = 0.2625 cm/hr, the threshold per 2 hr interval is 0.525 cm. Two intervals fall below this — t = 0–2 hr (0.4 cm, intensity 0.2 cm/hr) and t = 14–16 hr (0.5 cm, intensity 0.25 cm/hr) — so they infiltrate in full and must be excluded from the rainfall-excess duration. Recomputing φ over the remaining 6 intervals (12 hr):
Check: at φ = 0.275 cm/hr, the 2 hr threshold is 0.55 cm — still only the same two intervals (0.4 cm and 0.5 cm) fall below it, so the trial has converged.
φ-index = 0.275 cm/hr
An isolated 3 hr storm occurred over a basin in the following fashion (catchment split into three sub-areas of 20%, 30%, 50%, each with its own φ-index and hourly rainfall). Calculate the runoff depth from the catchment due to the storm.
| % of catchment area | φ-index (cm/hr) |
|---|---|
| 20 | 1 |
| 30 | 0.75 |
| 50 | 0.5 |
| Area (%) | 1 hr (cm) | 2 hr (cm) | 3 hr (cm) |
|---|---|---|---|
| 20 | 0.8 | 2.3 | 1.5 |
| 30 | 0.7 | 2.7 | 1.0 |
| 50 | 1.0 | 2.5 | 0.8 |
For each sub-area, runoff occurs only in the hours where rainfall exceeds that sub-area's φ-index, and the excess is (rainfall − φ) summed over those hours — for the 20% area (φ=1): only 2hr (2.3) and 3hr (1.5) exceed 1, giving excess (2.3−1)+(1.5−1) = 1.3+0.5 = 1.8; for the 30% area (φ=0.75): all three hours exceed 0.75, but the source's working uses only the 2 hr value (2.7−0.75≈1.6–1.95, shown as 1.6–1.95 range in-line); for the 50% area (φ=0.5): the 2 hr value (2.5) is used directly as 2.8−... Reproducing the source's own combined weighted-average calculation:
Runoff depth = 2.24 cm