Hydrology / Precipitation & Measurement

Precipitation & its Measurement

Converted from handwritten notes — Hydrology 02 Precipitation and it's Measurement.pdf, 38 pages

Doc No.HYD-02
StatusDraft — Awaiting Review
Converted28-07-2026
Approved—

Formation of Precipitation

Precipitation occurs if a sufficient number of hygroscopic nuclei and warmed, moist and unstable air are available. Warmed and moist air lifts up and becomes saturated; clouds are formed after condensation of water vapour around hygroscopic nuclei.

When the condensation nuclei join together, the droplet becomes larger and rainfall occurs.

Types of Rainfall

  1. Convective rainfall
  2. Orographic rainfall
  3. Frontal / cyclonic rainfall

Convective Rainfall

Convective rainfall occurs due to thermal convective currents caused by heating of the water surface. Moist air closer to the surface is hot and hence has lesser density; it rises up and becomes cooler due to adiabatic cooling, and ultimately precipitation occurs when that vapour has condensed.

P E Ocean

Convective rainfall — P: precipitation, E: evaporation from the heated water surface

Orographic Rainfall

Orographic rainfall occurs due to the rise of air forced by mountain barriers. Most of the rainfall in India is orographic in nature.

dry windward leeward

Orographic rainfall — moist air forced up the windward slope cools and precipitates; the leeward side stays comparatively dry (rain-shadow)

Frontal / Cyclonic Rainfall

This precipitation occurs due to upward movement of warm air caused by the convergence of hot and cold air masses. Warm air gets lifted up above the cold air mass, and hence condensation occurs.

front Hot air mass Cold air mass

Frontal / cyclonic rainfall — warm air rises over the advancing cold air mass along the front

Forms of Precipitation

FormCriterion
(1) Rainfall0.5 mm < size of droplet < 6 mm
(2) Drizzlesize of droplet < 0.5 mm
(3) Hail5 mm < size of pellet < 50 mm
(4) Sleet (water + ice)size of pellets < 5 mm
(5) Snowfalloccurs when the freezing point of water is close to the earth's surface

Measurement of Precipitation

Various types of raingauges are broadly classified as (a) non-recording gauge and (b) recording gauge. A raingauge is also known as an ombrometer, pluviometer, or hyetometer.

Non-Recording Gauge

The non-recording gauge extensively used in India is called Simon's gauge.

10 cm 8:30 am

Simon's raingauge — funnel over a graduated collecting cylinder

Recording Gauge

A recording gauge produces a continuous plot of rainfall against time, and hence the intensity of rainfall at various times can be obtained. The various recording-type raingauges are:

  1. Tipping bucket type
  2. Weighing bucket type
  3. Natural siphon type → used in India

Tipping Bucket Type

The bucket tips at every 0.25 mm of rainfall collection; this method gives the intensity of rainfall at various times. It can be used for remotely sensing the rainfall by receiving signals of each tipping.

Intensity of rainfall=0.25 mmt2−t1
t2 − t1 — time interval between tippings

Weighing Bucket Type

In this case, the accumulated rainfall is continuously weighed, and thus we get a mass curve of rainfall. The slope of the mass curve at any point represents the intensity of rainfall.

Intensity=rainfall per unit time

This gauge is most useful for measuring snowfall.

Accumulated rainfall (cm) time (hr) A B C D E Δt Δh mass curve

Weighing bucket type — the accumulated-rainfall trace only rises or plateaus; slope of curve = Δh/Δt = intensity of rainfall

Natural Siphon Type

This is the standard recording gauge used in India. In this case we get an accumulated rainfall vs. time curve, i.e. a mass curve. The vessel is emptied automatically by a siphon once it fills — the slope of the trace still represents the intensity of rainfall.

Accumulated rainfall (cm) time (hr) Syphoning points

Natural siphon gauge — the pen trace resets to zero at each siphoning point (self-emptying); the true accumulated-rainfall mass curve, once resets are added back, is monotonically increasing throughout

Raingauge Network Density

The more the variability of rainfall over an area, the more should be the number of raingauges per unit area. As per IS 4987:

TerrainRaingauge network density
Plain area1 per 520 km²
Moderately elevated area (avg. elevation ≤ 1000 m)1 per 260–390 km²
Hilly area (elevation > 1000 m)1 per 130 km²

As per WMO (World Meteorological Organization), 10% of raingauge stations should be of recording type.

Adequacy of Raingauge Stations

If the acceptable error in the rainfall measurement is more, the number of raingauge stations required in that area would be less. For a particular acceptable error, the number of raingauge stations required is calculated as below.

Step 1 — calculate Pm, the mean precipitation:

Pm=∑Pin
Pi — precipitation recorded at the ith station

Step 2 — calculate the standard deviation:

σn−1=∑(Pi−Pm)2n−1; n≤30 σn=∑(Pi−Pm)2n; n>30

Step 3 — calculate coefficient of variation (Cv, in fraction):

Cv=σn−1Pm

Step 4 — calculate the adequate number of raingauge stations (N):

N=(Cvε)2
ε — acceptable error, in fraction (e.g. acceptable error = 10% ⇒ ε = 0.1)
Worked Example — Raingauge Adequacy

A catchment has six raingauge stations. In a year, the annual rainfall data recorded by the gauges are as follows:

StationRainfall (cm)
182.6
2102.9
3180.3
4110.3
598.8
6136.7

(a) Determine the standard error in estimation of the mean rainfall in the existing set of raingauges. (b) For a 10% error of estimation, calculate the optimum number of raingauge stations required in the catchment.

Pm=118.6 cm, σn−1=35.036, Cv=σn−1Pm=0.295

(a) With N = 6 (existing stations), % error = ?

6=(0.295ε)2⇒ε=12.06%

(b) For 10% acceptable error:

N=(0.2950.1)2=8.703≈9

Hence, 9 stations are required for an error of 10%.

Normal Precipitation

Normal precipitation is the average value of rainfall of a particular date, month or year, over a specified 30-year period. The 30-year normal values are updated every decade to account for changes in environmental and land-use conditions.

It is used to find out the missing data for a certain raingauge station.

Preparation of Data

For any hydrological analysis we make use of records of previous rainfall data; the previous rainfall data must be continuous and consistent.

Estimation of Missing Data

Two methods: (1) arithmetic average method (2) normal ratio method.

1 2 3 6 4 5 X

Missing data at station X estimated from the surrounding raingauge stations 1–6

Arithmetic Average Method

Px=∑Pin
Px — precipitation of the missing-data station
Pi — precipitation of the jth (surrounding) station

This method is valid when the normal precipitations of the neighbouring stations (N1, N2, …, Nn) are within 10% of Nx:

0.9Nx<Ni<1.1Nx
Ni — normal precipitation at the ith station
Nx — normal precipitation at the missing-data station

If the normal precipitations of neighbouring stations are not within 10% of the normal precipitation of the missing-data station, the normal ratio method is used instead:

PxNx=1n⋅∑PiNi
Worked Example — Estimating Missing Data

Estimate the missing rainfall data for station X:

Raingauge stationNormal PPTActual PPT of year
A1125875
B9101021
C765915
X830(find)

Checking the 10% condition against Nx: station A's normal PPT (1125) does not satisfy 0.9Nx < Ni < 1.1Nx, so the normal ratio method is used.

x830=138751125+1021910+915765

x = 856.51

Inconsistency of Record

Common causes of inconsistency are:

  1. Shifting of the raingauge station to a new location.
  2. Climatic and topographical condition changing.
  3. Occurrence of observational errors from a certain date.

The inconsistency of record is corrected using the double mass curve technique.

Accumulated rainfall at station X (reverse chron.) Avg. accumulated rainfall of neighbouring stations (reverse chron.) → 2014 2013 2012 2011 2010 2009 2008 kink — inconsistency begins

Double mass curve — plotted in reverse chronological order (most recent year nearest the origin); a kink marks the year beyond which the data is inconsistent with present conditions

Correction Factor

Corrected data of 2009=P2009×βα=P2009×slope of OAslope of OB Correction factor=slope of OAslope of OB
Slope of OA — slope of the continuing (consistent) line
Slope of OB — slope of the shifted (inconsistent) line
2009 (P₂₀₀₉) β α O (2010)

Correction factor construction — α: angle of the continuing line OA, β: angle of the shifted line OB, at O

The appearance of a kink represents the year beyond which the data is not consistent with the present environmental and topographical condition. All such data are corrected by multiplying with the correction factor as shown above.

Presentation of Rainfall Data

Rainfall data is presented in the form of (a) mass curve, (b) hyetograph, (c) moving average.

Mass Curve

It is the plot of accumulated rainfall against time. The slope of the mass curve gives the intensity of rainfall.

Hyetograph

Hyetograph is the plot of intensity vs. time, in the form of a bar chart (hyetogram).

Intensity of rainfall (cm/hr) time (hr) 8 4 2 1 0 2 4 6 8

Illustrative hyetograph — bar height is the rainfall intensity within each interval

Area under hyetograph=total rainfall Volume of rainfall=total accumulated rainfall×catchment area

The area under the hyetograph represents the total depth of rainfall, and the volume of rainfall can be calculated by multiplying the area under the hyetograph with the catchment area.

Worked Example — Hyetograph & Volume of Rainfall

Catchment area = 10 km². Draw the hyetograph and find the volume of rainfall in ha-m, for the mass curve below:

acc. rainfall (cm) 10 16 31 31 43 2 5 8 10 12 mass curve intensity (cm/hr) 5 2 5 0 6 2 5 8 10 12 hyetograph

Mass curve (top, cm) and corresponding hyetograph (bottom, cm/hr) — intervals [0–2]:5, [2–5]:2, [5–8]:5, [8–10]:0, [10–12]:6 cm/hr

Volume of rainfall=43 cm×10 km2

Volume of rainfall = 430 ha-m

Moving Average Method

If we plot the rainfall in chronological order, the fluctuations in the plot would be large and it would be difficult to find out the trend of rainfall. Hence, to obtain a smoother plot, we make use of the moving average, which gives us the trend of rainfall.

To find out the three-year moving average, the average of the rainfall data of the 1st, 2nd and 3rd year is plotted against the 2nd year; the average of 2nd, 3rd and 4th year is plotted against the 3rd year, and so on. The same procedure is adopted to find the 5-year moving average. The number of years used should be odd. A 5-year moving average is smoother than a 3-year moving average.

Rainfall data year 3yr moving average

Moving average smooths the raw year-to-year fluctuation to reveal the underlying rainfall trend

Average Depth of Precipitation Over a Catchment

Data recorded at a raingauge station is actually a point rainfall data, i.e. data for a specified location. However, for hydrological calculation, we require rainfall over an area. The following methods are used to convert the point rainfall data to average rainfall over an area:

  1. Arithmetic average method
  2. Thiessen polygon method
  3. Isohyetal method

Arithmetic Average Method

In this method we simply take the average of the rainfalls of the raingauge stations located inside the catchment.

Pavg=∑Pin
Pi — raingauge stations located inside the catchment

This method gives equal weight to all raingauge stations and renders accurate results only if raingauges are distributed uniformly over the catchment and the climatic and topographical condition is uniform throughout the catchment. In reality, we do not adopt this method.

Thiessen Polygon Method

Pavg=∑PiAi∑Ai
Pi — precipitation at the ith raingauge station
Ai — area of influence of the ith raingauge station, obtained by intersecting its Thiessen polygon with the catchment area

The area of influence of the ith station is obtained by the Thiessen polygon method. A Thiessen polygon is obtained by joining the perpendicular bisectors of the triangles formed when various raingauge stations are joined.

A B C catchment boundary (dashed)

Thiessen polygons (simplified, equally-spaced gauges) — each polygon's perpendicular-bisector cell, intersected with the catchment boundary, gives that gauge's area of influence Ai

Isohyetal Method

Isohyets — lines joining equal rainfall magnitudes. The area between two isohyets is measured using a planimeter.

Pavg=P1A0+P1+P22A1+…+P5A5Total area (∑Ai)

In general form (Pij = average of the two isohyet values bounding strip Aij):

Pavg=∑PijAij∑Aij; Pij=Pi+Pj2
If P0 is given for the outermost strip A0, use (P0 + P1)/2 × A0 for that term instead.
A0 A1 A2 A3 A4 A5 P1 P2 P3 P4 P5

Isohyetal method — the catchment split into strips A0–A5 by successive isohyets P1–P5; each divider meets the catchment boundary exactly, so every strip is a closed region

Worked Example — Arithmetic Average vs. Thiessen Polygon

Calculate the average depth of rainfall for the catchment using the arithmetic average method and the Thiessen polygon method:

StationRainfall Pi (cm)Area of influence Ai (km²)Station
110100Inside
22050Outside
315100Inside
45125Inside
51050Outside
65100Outside
720200Inside
81050Inside
Arithmetic avg. method=10+15+5+20+105=12 cm

(using only the 5 stations located inside the catchment)

Thiessen polygon method=∑PA∑A=12.419 cm
Worked Example — Circular Catchment, Five Raingauges

PA = 100 cm (centre gauge), PB = 90 cm, PC = 110 cm, PD = 120 cm, PE = 80 cm. Calculate the average depth of rainfall for the catchment (circle of diameter 20 km) using the Thiessen polygon method.

A (100 km²) B C D E A0

Central square (side 10 km, area 100 km², gauge A) surrounded by 4 congruent "petal" regions (each A0, gauge B/C/D/E) between the square and the circle of diameter 20 km — the 4 petals are congruent by symmetry

A0=π4202−1024=53.539 km2
Pavg=100×100+53.539×(90+110+120+80)π4202

Pavg = 100 cm

Worked Example — Isohyetes for Annual Rainfall (by strip area)

Isohyets for the annual rainfall over the catchment basin were drawn. The area of the strip between the isohyets is given below. Determine the average precipitation over the catchment basin.

Isohyetes (cm)Area (km²)
75–851600
85–953600
95–1052800
105–1151000
115–135900
135–155700
Pavg=∑Pi,avg×Ai∑Ai

Pavg = 99.62 cm

Worked Example — Isohyetal Method (ring areas)

Calculate the average rainfall over the catchment using the isohyetal method for the following data:

Isohyete (mm)Enclosed area (km²)Individual area (km²)
21543543
201345802
192030685
182545515
172955410
17 18 19 20 21

Isohyet rings (mm), each strictly nested inside the last — enclosed areas as given in the table

Pavg=(Pi+Pj)/2×Aij∑Aij=21×543+20.5×802+19.5×685+18.5×515+17.5×4102955

Pavg = 19.595 mm

Depth-Area-Duration (DAD) Curve

Normally in a catchment, a particular rainfall occurs at maximum intensity near the storm centre; as the distance increases from the storm centre, the intensity of rainfall decreases.

Depth of rainfall at a raingauge station is called point rainfall. To convert this point rainfall to areal data, i.e. to find out how much rainfall will occur over various areas, we use the depth-area curve.

  1. From the data of rainfall from various stations, isohyetal maps are plotted.
  2. Area between the isohyets is determined by planimeter.
  3. Volume of rainfall over various areas is calculated.
  4. Cumulative volume and cumulative area are calculated.
  5. Cumulative volume is divided by cumulative area to obtain the average depth of rainfall over the cumulative area.

While calculating the DAD curve, the duration of rainfall is selected. Different depth-area curves are obtained for different durations of rainfall.

Depth of rainfall Area 2hr 4hr 8hr

DAD curve family — (1) depth decreases with increase in area, (2) average depth increases with increase in duration of rainfall

Maximum Depth-Area-Duration Curve

To design any hydraulic structure, we need to find the flood, and it is obtained from the design rainfall. The design rainfall over an area is taken as the maximum rainfall of a particular duration over a particular area. This is obtained from the maximum DAD curve. To find out the maximum DAD curve for a particular duration, we find the maximum rainfall of that duration occurring at any time.

Worked Example — Maximum DAD Curve

A catchment is divided into three zones — zone 1, zone 2 and zone 3 — with area of each zone as 100 km², 3000 km² and 3000 km² respectively. The cumulative average rainfall in mm in the different zones for a particular rainfall is as given below. Draw the maximum average-depth vs. area plot for the rainfall durations of 2 hr, 4 hr and 6 hr.

Time (hr)Zone 1Zone 2Zone 3
2852
414117
6231812
8392821
10484030

For each duration, the maximum X-hour rainfall occurring anywhere within the record is found for each zone (sequence of filling: smaller area to larger; if area is same, larger intensity to smaller). Cumulative volume and cumulative area are then used to get the average depth over each cumulative area:

DurationZoneArea A (km²)Max. depth D (mm)Volume V (km²·mm)Cum. VCum. AAvg. depth (mm)
2 hr1100161600160010016
23000123600037600310012.13
3300092700064600610010.59
4 hr1100252500250010025
23000226600068500310022.09
330001854000122500610020.08
6 hr1100343400340010034
23000298700090400310029.16
330002369000159400610026.13
Max. depth (mm) Area (km²) 100 3100 6100 2hr 4hr 6hr

Maximum DAD curve — depth decreases with area within each duration, and increases with duration at any fixed area, exactly as computed in the table above

Frequency of Point Rainfall

In hydrological design, we need to know the chance of occurrence of a particular rainfall, or the probability that a particular rainfall will be exceeded during the design life of the structure. For this purpose, a time series of rainfall is obtained — annual series, monthly series, etc. Annual series is used for the design of hydraulic structures; in this series, the maximum rainfall of every year is tabulated year-wise.

Worked Example — Return Period (Weibull's Formula)
YearRainfall (mm)
1960180
1961185
1962150
1963160
1964195
1965200

To obtain the probability of rainfall being equal to or exceeded (P), the annual series is arranged in decreasing order of magnitude and a serial (order) number m is assigned to each value; N is the number of years of record (here N = 6).

Rainfall (mm)Order no. (m)P = m/(N+1)
20011/7
19522/7
18533/7
18044/7
16055/7
15066/7
P=mN+1 (Weibull's formula) P=mN (California's formula) P=m−0.5N (Hazen's formula)

This approach of finding the probability of exceedance is called the plotting position approach.

Return period (T)=1P; by Weibull's approach T=N+1m

For 195 mm (m = 2): T = 1/(2/7) = 3.5 years. In 100 years, 100/3.5 = 28.57 — i.e. the 195 mm rainfall can be predicted to be equalled or exceeded 28.57 times.

If a particular data value appears in the annual series more than once, the order number used for the repeated data is the larger one (choose the worse condition):

RainfallOrder no. (m)
2001
1952
1853
1854 ← used
1705
1606
1607 ← used
1558

In this example, 185 mm rainfall is given order no. 4 (not 3), and 160 mm is given order no. 7 (not 6) — the larger order number is used for repeated values.

Probability Formulas

P — probability of exceedance.

  1. Probability of non-exceedance: q = 1 − P.
  2. Probability of exceedance 'r' times in 'n' successive years:
Cn[r]prqn−r
  1. Probability of non-occurrence (non-exceedance) in 'n' successive years:
Cn[0]p0qn−0=qn
  1. Probability of occurrence at least once in 'n' successive years:
1−qn
Worked Example — 70 Years of Annual Rainfall Records

Annual PPT value at a place, having 70 years of records, can be tabulated as follows. Calculate the probability of having: (a) annual rainfall equal to or greater than 120 cm in a year; (b) two successive years in which annual rainfall is equal to or greater than 140 cm; (c) annual rainfall less than 60 cm in any year.

Range (cm)No. of years
< 606
60–79.96
80–99.922
100–119.925
120–139.98
> 1403
RangeCumulative order no. (m)
> 140 cm3
120–139.9 cm11
100–119.9 cm36
80–99.9 cm58
60–79.9 cm64
< 60 cm70

(a) Using Weibull's formula, N = 70:

P(>120 cm)=1171=15.49%

(b) Probability of exceedance in 2 successive years:

P(>140 cm)=371; P in 2 successive years=371×371=0.178%

(c) Using the complement, since only exceedance probability can be found directly:

P(>60 cm)=6471; P(<60 cm)=1−6471=771=9.85%

Intensity-Duration-Frequency (IDF) Curve

IDF curves are used for risk assessment of dams, bridges, drainage systems and storm sewers.

max. intensity (cm/hr) Duration (hr) 5yr 10yr 15yr frequency (return period)

IDF curve — max. intensity vs. duration, by return period; higher return period gives a higher curve

max. intensity (cm/hr) Frequency (years) 2hr 4hr 6hr

IDF curve — max. intensity vs. frequency (return period), by duration; shorter duration gives a higher curve

Worked Example — Max. Intensity-Duration & Max. Depth-Duration Curves

Draw the maximum intensity-duration-frequency curve and maximum depth-duration curve for the following data:

Time since start (min)Cumulative rainfall (mm)
00
306
6018
9021
12036
15043
18049
21052
24053
27054

The various rainfalls occurring in each duration window are found, and the maximum for each duration is picked out:

Duration (min)Max. depth of rainfall (mm)Max. intensity (mm/hr)
301530
602222
903020
1203718.5
1504317.2
1804916.33
max. intensity (mm/hr) duration (hr) ½ 1 2 3

Max. intensity vs. duration — intensity strictly decreases as duration increases

max. depth (mm) duration (hr) ½ 1 2 3

Max. depth vs. duration — cumulative depth strictly increases as duration increases

Probable Maximum Precipitation (PMP)

It is defined as the greatest or extreme rainfall of a given duration that is physically possible over a station or basin. In this case, the DAD of PMP is required to be obtained for the design of a hydraulic structure. To obtain the DAD of PMP, the maximum is adjusted for the most favourable condition that is possible to maximize the rainfall.

PMP=P¯+Kσ
P̄ — average rainfall of annual series
K — frequency factor
σ — standard deviation of annual series

PMP is used for the design of large hydraulic structures for which virtually there is no possibility of exceedance.

Standard Project Storm (SPS)

It is used for the design of major and intermediate-importance structures. It is the greatest storm that is expected without modifying the rainfall data for the most favourable condition.

World Record Envelope

Pm (cm)=42.16D0.475 (hr)

Maximum rainfall observed in any part of the world for a given duration.

Pm — extreme rainfall depth, in cm
D — duration, in hr