Hydrology / Precipitation & Measurement
Precipitation occurs if a sufficient number of hygroscopic nuclei and warmed, moist and unstable air are available. Warmed and moist air lifts up and becomes saturated; clouds are formed after condensation of water vapour around hygroscopic nuclei.
When the condensation nuclei join together, the droplet becomes larger and rainfall occurs.
Convective rainfall occurs due to thermal convective currents caused by heating of the water surface. Moist air closer to the surface is hot and hence has lesser density; it rises up and becomes cooler due to adiabatic cooling, and ultimately precipitation occurs when that vapour has condensed.
Convective rainfall — P: precipitation, E: evaporation from the heated water surface
Orographic rainfall occurs due to the rise of air forced by mountain barriers. Most of the rainfall in India is orographic in nature.
Orographic rainfall — moist air forced up the windward slope cools and precipitates; the leeward side stays comparatively dry (rain-shadow)
This precipitation occurs due to upward movement of warm air caused by the convergence of hot and cold air masses. Warm air gets lifted up above the cold air mass, and hence condensation occurs.
Frontal / cyclonic rainfall — warm air rises over the advancing cold air mass along the front
| Form | Criterion |
|---|---|
| (1) Rainfall | 0.5 mm < size of droplet < 6 mm |
| (2) Drizzle | size of droplet < 0.5 mm |
| (3) Hail | 5 mm < size of pellet < 50 mm |
| (4) Sleet (water + ice) | size of pellets < 5 mm |
| (5) Snowfall | occurs when the freezing point of water is close to the earth's surface |
Various types of raingauges are broadly classified as (a) non-recording gauge and (b) recording gauge. A raingauge is also known as an ombrometer, pluviometer, or hyetometer.
The non-recording gauge extensively used in India is called Simon's gauge.
Simon's raingauge — funnel over a graduated collecting cylinder
A recording gauge produces a continuous plot of rainfall against time, and hence the intensity of rainfall at various times can be obtained. The various recording-type raingauges are:
The bucket tips at every 0.25 mm of rainfall collection; this method gives the intensity of rainfall at various times. It can be used for remotely sensing the rainfall by receiving signals of each tipping.
In this case, the accumulated rainfall is continuously weighed, and thus we get a mass curve of rainfall. The slope of the mass curve at any point represents the intensity of rainfall.
This gauge is most useful for measuring snowfall.
Weighing bucket type — the accumulated-rainfall trace only rises or plateaus; slope of curve = Δh/Δt = intensity of rainfall
This is the standard recording gauge used in India. In this case we get an accumulated rainfall vs. time curve, i.e. a mass curve. The vessel is emptied automatically by a siphon once it fills — the slope of the trace still represents the intensity of rainfall.
Natural siphon gauge — the pen trace resets to zero at each siphoning point (self-emptying); the true accumulated-rainfall mass curve, once resets are added back, is monotonically increasing throughout
The more the variability of rainfall over an area, the more should be the number of raingauges per unit area. As per IS 4987:
| Terrain | Raingauge network density |
|---|---|
| Plain area | 1 per 520 km² |
| Moderately elevated area (avg. elevation ≤ 1000 m) | 1 per 260–390 km² |
| Hilly area (elevation > 1000 m) | 1 per 130 km² |
As per WMO (World Meteorological Organization), 10% of raingauge stations should be of recording type.
If the acceptable error in the rainfall measurement is more, the number of raingauge stations required in that area would be less. For a particular acceptable error, the number of raingauge stations required is calculated as below.
Step 1 — calculate Pm, the mean precipitation:
Step 2 — calculate the standard deviation:
Step 3 — calculate coefficient of variation (Cv, in fraction):
Step 4 — calculate the adequate number of raingauge stations (N):
A catchment has six raingauge stations. In a year, the annual rainfall data recorded by the gauges are as follows:
| Station | Rainfall (cm) |
|---|---|
| 1 | 82.6 |
| 2 | 102.9 |
| 3 | 180.3 |
| 4 | 110.3 |
| 5 | 98.8 |
| 6 | 136.7 |
(a) Determine the standard error in estimation of the mean rainfall in the existing set of raingauges. (b) For a 10% error of estimation, calculate the optimum number of raingauge stations required in the catchment.
(a) With N = 6 (existing stations), % error = ?
(b) For 10% acceptable error:
Hence, 9 stations are required for an error of 10%.
Normal precipitation is the average value of rainfall of a particular date, month or year, over a specified 30-year period. The 30-year normal values are updated every decade to account for changes in environmental and land-use conditions.
It is used to find out the missing data for a certain raingauge station.
For any hydrological analysis we make use of records of previous rainfall data; the previous rainfall data must be continuous and consistent.
Two methods: (1) arithmetic average method (2) normal ratio method.
Missing data at station X estimated from the surrounding raingauge stations 1–6
This method is valid when the normal precipitations of the neighbouring stations (N1, N2, …, Nn) are within 10% of Nx:
If the normal precipitations of neighbouring stations are not within 10% of the normal precipitation of the missing-data station, the normal ratio method is used instead:
Estimate the missing rainfall data for station X:
| Raingauge station | Normal PPT | Actual PPT of year |
|---|---|---|
| A | 1125 | 875 |
| B | 910 | 1021 |
| C | 765 | 915 |
| X | 830 | (find) |
Checking the 10% condition against Nx: station A's normal PPT (1125) does not satisfy 0.9Nx < Ni < 1.1Nx, so the normal ratio method is used.
x = 856.51
Common causes of inconsistency are:
The inconsistency of record is corrected using the double mass curve technique.
Double mass curve — plotted in reverse chronological order (most recent year nearest the origin); a kink marks the year beyond which the data is inconsistent with present conditions
Correction factor construction — α: angle of the continuing line OA, β: angle of the shifted line OB, at O
The appearance of a kink represents the year beyond which the data is not consistent with the present environmental and topographical condition. All such data are corrected by multiplying with the correction factor as shown above.
Rainfall data is presented in the form of (a) mass curve, (b) hyetograph, (c) moving average.
It is the plot of accumulated rainfall against time. The slope of the mass curve gives the intensity of rainfall.
Hyetograph is the plot of intensity vs. time, in the form of a bar chart (hyetogram).
Illustrative hyetograph — bar height is the rainfall intensity within each interval
The area under the hyetograph represents the total depth of rainfall, and the volume of rainfall can be calculated by multiplying the area under the hyetograph with the catchment area.
Catchment area = 10 km². Draw the hyetograph and find the volume of rainfall in ha-m, for the mass curve below:
Mass curve (top, cm) and corresponding hyetograph (bottom, cm/hr) — intervals [0–2]:5, [2–5]:2, [5–8]:5, [8–10]:0, [10–12]:6 cm/hr
Volume of rainfall = 430 ha-m
If we plot the rainfall in chronological order, the fluctuations in the plot would be large and it would be difficult to find out the trend of rainfall. Hence, to obtain a smoother plot, we make use of the moving average, which gives us the trend of rainfall.
To find out the three-year moving average, the average of the rainfall data of the 1st, 2nd and 3rd year is plotted against the 2nd year; the average of 2nd, 3rd and 4th year is plotted against the 3rd year, and so on. The same procedure is adopted to find the 5-year moving average. The number of years used should be odd. A 5-year moving average is smoother than a 3-year moving average.
Moving average smooths the raw year-to-year fluctuation to reveal the underlying rainfall trend
Data recorded at a raingauge station is actually a point rainfall data, i.e. data for a specified location. However, for hydrological calculation, we require rainfall over an area. The following methods are used to convert the point rainfall data to average rainfall over an area:
In this method we simply take the average of the rainfalls of the raingauge stations located inside the catchment.
This method gives equal weight to all raingauge stations and renders accurate results only if raingauges are distributed uniformly over the catchment and the climatic and topographical condition is uniform throughout the catchment. In reality, we do not adopt this method.
The area of influence of the ith station is obtained by the Thiessen polygon method. A Thiessen polygon is obtained by joining the perpendicular bisectors of the triangles formed when various raingauge stations are joined.
Thiessen polygons (simplified, equally-spaced gauges) — each polygon's perpendicular-bisector cell, intersected with the catchment boundary, gives that gauge's area of influence Ai
Isohyets — lines joining equal rainfall magnitudes. The area between two isohyets is measured using a planimeter.
In general form (Pij = average of the two isohyet values bounding strip Aij):
Isohyetal method — the catchment split into strips A0–A5 by successive isohyets P1–P5; each divider meets the catchment boundary exactly, so every strip is a closed region
Calculate the average depth of rainfall for the catchment using the arithmetic average method and the Thiessen polygon method:
| Station | Rainfall Pi (cm) | Area of influence Ai (km²) | Station |
|---|---|---|---|
| 1 | 10 | 100 | Inside |
| 2 | 20 | 50 | Outside |
| 3 | 15 | 100 | Inside |
| 4 | 5 | 125 | Inside |
| 5 | 10 | 50 | Outside |
| 6 | 5 | 100 | Outside |
| 7 | 20 | 200 | Inside |
| 8 | 10 | 50 | Inside |
(using only the 5 stations located inside the catchment)
PA = 100 cm (centre gauge), PB = 90 cm, PC = 110 cm, PD = 120 cm, PE = 80 cm. Calculate the average depth of rainfall for the catchment (circle of diameter 20 km) using the Thiessen polygon method.
Central square (side 10 km, area 100 km², gauge A) surrounded by 4 congruent "petal" regions (each A0, gauge B/C/D/E) between the square and the circle of diameter 20 km — the 4 petals are congruent by symmetry
Pavg = 100 cm
Isohyets for the annual rainfall over the catchment basin were drawn. The area of the strip between the isohyets is given below. Determine the average precipitation over the catchment basin.
| Isohyetes (cm) | Area (km²) |
|---|---|
| 75–85 | 1600 |
| 85–95 | 3600 |
| 95–105 | 2800 |
| 105–115 | 1000 |
| 115–135 | 900 |
| 135–155 | 700 |
Pavg = 99.62 cm
Calculate the average rainfall over the catchment using the isohyetal method for the following data:
| Isohyete (mm) | Enclosed area (km²) | Individual area (km²) |
|---|---|---|
| 21 | 543 | 543 |
| 20 | 1345 | 802 |
| 19 | 2030 | 685 |
| 18 | 2545 | 515 |
| 17 | 2955 | 410 |
Isohyet rings (mm), each strictly nested inside the last — enclosed areas as given in the table
Pavg = 19.595 mm
Normally in a catchment, a particular rainfall occurs at maximum intensity near the storm centre; as the distance increases from the storm centre, the intensity of rainfall decreases.
Depth of rainfall at a raingauge station is called point rainfall. To convert this point rainfall to areal data, i.e. to find out how much rainfall will occur over various areas, we use the depth-area curve.
While calculating the DAD curve, the duration of rainfall is selected. Different depth-area curves are obtained for different durations of rainfall.
DAD curve family — (1) depth decreases with increase in area, (2) average depth increases with increase in duration of rainfall
To design any hydraulic structure, we need to find the flood, and it is obtained from the design rainfall. The design rainfall over an area is taken as the maximum rainfall of a particular duration over a particular area. This is obtained from the maximum DAD curve. To find out the maximum DAD curve for a particular duration, we find the maximum rainfall of that duration occurring at any time.
A catchment is divided into three zones — zone 1, zone 2 and zone 3 — with area of each zone as 100 km², 3000 km² and 3000 km² respectively. The cumulative average rainfall in mm in the different zones for a particular rainfall is as given below. Draw the maximum average-depth vs. area plot for the rainfall durations of 2 hr, 4 hr and 6 hr.
| Time (hr) | Zone 1 | Zone 2 | Zone 3 |
|---|---|---|---|
| 2 | 8 | 5 | 2 |
| 4 | 14 | 11 | 7 |
| 6 | 23 | 18 | 12 |
| 8 | 39 | 28 | 21 |
| 10 | 48 | 40 | 30 |
For each duration, the maximum X-hour rainfall occurring anywhere within the record is found for each zone (sequence of filling: smaller area to larger; if area is same, larger intensity to smaller). Cumulative volume and cumulative area are then used to get the average depth over each cumulative area:
| Duration | Zone | Area A (km²) | Max. depth D (mm) | Volume V (km²·mm) | Cum. V | Cum. A | Avg. depth (mm) |
|---|---|---|---|---|---|---|---|
| 2 hr | 1 | 100 | 16 | 1600 | 1600 | 100 | 16 |
| 2 | 3000 | 12 | 36000 | 37600 | 3100 | 12.13 | |
| 3 | 3000 | 9 | 27000 | 64600 | 6100 | 10.59 | |
| 4 hr | 1 | 100 | 25 | 2500 | 2500 | 100 | 25 |
| 2 | 3000 | 22 | 66000 | 68500 | 3100 | 22.09 | |
| 3 | 3000 | 18 | 54000 | 122500 | 6100 | 20.08 | |
| 6 hr | 1 | 100 | 34 | 3400 | 3400 | 100 | 34 |
| 2 | 3000 | 29 | 87000 | 90400 | 3100 | 29.16 | |
| 3 | 3000 | 23 | 69000 | 159400 | 6100 | 26.13 |
Maximum DAD curve — depth decreases with area within each duration, and increases with duration at any fixed area, exactly as computed in the table above
In hydrological design, we need to know the chance of occurrence of a particular rainfall, or the probability that a particular rainfall will be exceeded during the design life of the structure. For this purpose, a time series of rainfall is obtained — annual series, monthly series, etc. Annual series is used for the design of hydraulic structures; in this series, the maximum rainfall of every year is tabulated year-wise.
| Year | Rainfall (mm) |
|---|---|
| 1960 | 180 |
| 1961 | 185 |
| 1962 | 150 |
| 1963 | 160 |
| 1964 | 195 |
| 1965 | 200 |
To obtain the probability of rainfall being equal to or exceeded (P), the annual series is arranged in decreasing order of magnitude and a serial (order) number m is assigned to each value; N is the number of years of record (here N = 6).
| Rainfall (mm) | Order no. (m) | P = m/(N+1) |
|---|---|---|
| 200 | 1 | 1/7 |
| 195 | 2 | 2/7 |
| 185 | 3 | 3/7 |
| 180 | 4 | 4/7 |
| 160 | 5 | 5/7 |
| 150 | 6 | 6/7 |
This approach of finding the probability of exceedance is called the plotting position approach.
For 195 mm (m = 2): T = 1/(2/7) = 3.5 years. In 100 years, 100/3.5 = 28.57 — i.e. the 195 mm rainfall can be predicted to be equalled or exceeded 28.57 times.
If a particular data value appears in the annual series more than once, the order number used for the repeated data is the larger one (choose the worse condition):
| Rainfall | Order no. (m) |
|---|---|
| 200 | 1 |
| 195 | 2 |
| 185 | 3 |
| 185 | 4 ← used |
| 170 | 5 |
| 160 | 6 |
| 160 | 7 ← used |
| 155 | 8 |
In this example, 185 mm rainfall is given order no. 4 (not 3), and 160 mm is given order no. 7 (not 6) — the larger order number is used for repeated values.
P — probability of exceedance.
Annual PPT value at a place, having 70 years of records, can be tabulated as follows. Calculate the probability of having: (a) annual rainfall equal to or greater than 120 cm in a year; (b) two successive years in which annual rainfall is equal to or greater than 140 cm; (c) annual rainfall less than 60 cm in any year.
| Range (cm) | No. of years |
|---|---|
| < 60 | 6 |
| 60–79.9 | 6 |
| 80–99.9 | 22 |
| 100–119.9 | 25 |
| 120–139.9 | 8 |
| > 140 | 3 |
| Range | Cumulative order no. (m) |
|---|---|
| > 140 cm | 3 |
| 120–139.9 cm | 11 |
| 100–119.9 cm | 36 |
| 80–99.9 cm | 58 |
| 60–79.9 cm | 64 |
| < 60 cm | 70 |
(a) Using Weibull's formula, N = 70:
(b) Probability of exceedance in 2 successive years:
(c) Using the complement, since only exceedance probability can be found directly:
IDF curves are used for risk assessment of dams, bridges, drainage systems and storm sewers.
IDF curve — max. intensity vs. duration, by return period; higher return period gives a higher curve
IDF curve — max. intensity vs. frequency (return period), by duration; shorter duration gives a higher curve
Draw the maximum intensity-duration-frequency curve and maximum depth-duration curve for the following data:
| Time since start (min) | Cumulative rainfall (mm) |
|---|---|
| 0 | 0 |
| 30 | 6 |
| 60 | 18 |
| 90 | 21 |
| 120 | 36 |
| 150 | 43 |
| 180 | 49 |
| 210 | 52 |
| 240 | 53 |
| 270 | 54 |
The various rainfalls occurring in each duration window are found, and the maximum for each duration is picked out:
| Duration (min) | Max. depth of rainfall (mm) | Max. intensity (mm/hr) |
|---|---|---|
| 30 | 15 | 30 |
| 60 | 22 | 22 |
| 90 | 30 | 20 |
| 120 | 37 | 18.5 |
| 150 | 43 | 17.2 |
| 180 | 49 | 16.33 |
Max. intensity vs. duration — intensity strictly decreases as duration increases
Max. depth vs. duration — cumulative depth strictly increases as duration increases
It is defined as the greatest or extreme rainfall of a given duration that is physically possible over a station or basin. In this case, the DAD of PMP is required to be obtained for the design of a hydraulic structure. To obtain the DAD of PMP, the maximum is adjusted for the most favourable condition that is possible to maximize the rainfall.
PMP is used for the design of large hydraulic structures for which virtually there is no possibility of exceedance.
It is used for the design of major and intermediate-importance structures. It is the greatest storm that is expected without modifying the rainfall data for the most favourable condition.
Maximum rainfall observed in any part of the world for a given duration.