Geotechnical Engineering / Soil Mechanics

Permeability — Darcy's Law, Lab & Field Tests

Converted from handwritten notes — 13 Soil mechanics.pdf, pages 1 to 11

Doc No.GEO-13
StatusDraft — Awaiting Review
Converted09-08-2026
Approved—

Permeability — Darcy's Law

Q=kiA

k → coefficient of permeability.

QA=v=ki

v → discharge velocity.

water passes through pore only AΎporeῬ Area A

Water flows only through the pore space (Apore) of the total cross-section A — discharge velocity v treats the whole area as flow area, but the actual (seepage) velocity through the pores is higher.

vactual=QApore=vseepage=QA×AporeA
vactual=vdischargen

n → porosity. Coefficient of permeability is also called hydraulic conductivity.

SoilTypical k
Gravel> 1 cm/s
Sand1–10−3 cm/s
Silt10−3–10−6 cm/s
Clay< 10−6 cm/s

Determination of Coefficient of Permeability

Coefficient of permeability depends on the average size of pore, which in turn depends on particle size, particle shape, and soil structure. Disturbance to the soil structure on sampling will be greater in the case of fine-grained soil as compared to coarse-grained soil. Hence, for fine-grained soil, it is preferable to perform in-situ testing for k determination.

Constant Head Permeability Test

Adopted for coarse-grained soil, which is fully saturated.

level is fixed h L q area: A

Constant head permeameter: soil sample of length L, area A, with the supply water level held fixed to maintain a constant head h across the sample; outflow q collected over time.

q=khLA
k=qLAh

Falling Head Permeability Test

It is adopted for fine-grained soil.

a–area dh, dt at time t after tΎ0Ῥ time Soil hΎ1Ῥ hΎ2Ῥ L h area: A

Falling head permeameter: standpipe of area a above the soil sample of length L and area A; head falls from h1 to h2 over elapsed time t0.

−dh×adt=kiA=khLA −dhh=kALadt ∫h1h2−dhh=∫0t0kALadt ln(h1h2)=kALa⋅t0
k=LaAt0ln(h1h2)

k from the consolidation test

k=Cvmvγw

Cv = coefficient of consolidation, mv = coefficient of volume compressibility, γw = unit weight of water.

In-Situ Testing

1. Well Pumping Test (Unconfined Aquifer, Fully Penetrating Well)

Rock unconfined aquifer depressed water table observation well hΎ1Ῥ hΎ2Ῥ hΎwῬ HΎ0Ῥ RΎ0Ῥ Q

Fully penetrating pumped well drawing down the water table from H0 to hw at the well, with observation wells recording h1, h2 at radii r1, r2.

r

Radial flow toward the well: at radius r, all flow lines cross a cylindrical surface of area 2πrh.

Q=k⋅dhdr⋅2πrh hdh=Q2πkdrr ∫h2h1hdh=Q2πk∫r2r1drr h12−h222=Q2πkln(r1r2)
k=Qln(r1/r2)π(h12−h22)

In terms of the well radius rw and the radius of influence R (Dupuit's equation):

k=Qln(R/rw)π(H02−h02)

rw = radius of well, R = radius of influence, H0 = original level of water table, h0 = depth of water in well.

2. Well Pumping Test — Confined (Artesian) Aquifer

potentiometric level impermeable layer confined (artesian) aquifer Q hΎ1Ῥ hΎ2Ῥ h r D

Artesian aquifer of thickness D confined between two impermeable layers; the pumped well draws down the potentiometric surface within the aquifer.

Q=kdhdr(2πrD) dh=Q2πkDdrr ∫h2h1dh=Q2πkD∫r2r1drr
k=Qln(r1/r2)2πD(h1−h2)  k=Qln(R/rw)2πD(H0−h0)

H0 − h0 → drawdown in the well:

R=3000sK

R → m, s → m, K → m/s (s = H0 − h0 = drawdown).

Factors Affecting Permeability

k=C⋅de2γwμe31+e

de → effective (representative) grain size, de ∝ 1/specific surface. μ → dynamic viscosity of fluid. C → shape factor, depends on shape of particles.

Effect of grain size — Allen Hazen formula

k(m/s)=CD102(mm),  C∈(0.4,1.2) k(cm/s)=100D102(cm)

Effect of the permeant fluid

k∝γμ

Variation of γ with temperature is not significant, hence k is directly proportional to 1/μ.

k∝1μ

Effect of void ratio

k1k2=C1⋅e131+e1C2⋅e231+e2

Generally, in case of sand, C1 = C2, hence:

k1k2=e13/(1+e1)e23/(1+e2)

Other factors

Permeability of Stratified Soil

1. Flow Parallel to the Bedding Plane

HΎ1Ῥ KΎ1Ῥ hΎL1Ῥ qΎ1Ῥ HΎ2Ῥ KΎ2Ῥ hΎL2Ῥ qΎ2Ῥ HΎ3Ῥ KΎ3Ῥ hΎL3Ῥ qΎ3Ῥ Q L H1+H2+H3 hΎLῬ KΎeqῬ ≡ Q

Three horizontal layers of thickness H1, H2, H3 (permeabilities K1, K2, K3) with flow parallel to the bedding, replaced by a single equivalent layer of thickness H1+H2+H3 and permeability Keq.

Since head loss is the same across all layers (they share the same top and bottom equipotential surfaces, flow being parallel to the layering):

i=hL1L=hL2L=hL3L=hLL i=i1=i2=i3=ieq

Total discharge is the sum of each layer's discharge (per unit width):

Q=q1+q2+q3=K1iH1+K2iH2+K3iH3 Q=Keq(H1+H2+H3)i
Keq=K1H1+K2H2+K3H3H1+H2+H3

2. Flow Perpendicular to the Bedding Plane

K1 H1 hL1 K2 H2 hL2 K3 H3 hL3 Q L Q ≡ H1+H2+H3, KΎeqῬ, hΎLῬ Q Q

Same three layers, now with flow perpendicular to the bedding plane (through each layer in series) — total head loss is the sum of each layer's individual head loss, and Q (same discharge through every layer) must match across all three.

hL=hL1+hL2+hL3

Same Q through every layer (continuity), area L×1 (per unit width):

Q=kiA=K1hL1H1(L×1)=K2hL2H2(L×1)=K3hL3H3(L×1) Q=Keq⋅hL1+hL2+hL3H1+H2+H3×L×1

Substituting hL1=QH1/(K1L), etc. and dividing through by Q·(H1+H2+H3)/(Keq·L):

H1+H2+H3KeqL=H1K1L+H2K2L+H3K3L
Keq=H1+H2+H3H1K1+H2K2+H3K3
Which form to use Flow parallel to bedding gives a thickness-weighted arithmetic mean of K (dominated by the most permeable layer — a thin gravel seam can carry most of the flow). Flow perpendicular to bedding gives a thickness-weighted harmonic mean of K (dominated by the least permeable layer — a thin clay seam controls the overall rate, exactly like resistors in series vs. parallel).