Geotechnical Engineering / Field Density Testing
Review copy — each diagram below is shown next to your original handwritten page. Remove all "Your original" panels before publishing.
The unit weight (bulk unit weight) of soil in the field is found from the basic definition — weight of a soil sample divided by the volume it occupies:
W = weight of the soil sample taken; V = volume it occupied in the ground
The whole difficulty of a field density test is measuring V accurately without disturbing the soil. Various methods are used:
A field method — a steel cutter of known internal volume is driven into the soil, so the volume of the extracted core (V in γt = W/V) is already known without any further calculation.
Used precisely where the core cutter method is not suitable — for example for sandy, gravelly, or dry soil that won't hold together as a core.
Your original — page 1
Sand-pouring cylinder over the calibrating hole: sand from the cylinder fills the cone and the excavated hole below it.
Let V1 = volume of sand run out of the cylinder to fill both the hole and the cone, V2 = volume of sand needed to fill the cone alone (found separately, by calibration on a flat glass plate), and V3 is used the same way in the calibration step (volume of sand left in the cylinder after only the cone is filled, referenced back to the initial full reading):
Subtracting the second line from the first cancels the cone term and leaves the volume of soil (i.e. of the excavated hole) directly:
An undisturbed chunk (clod) of soil is coated with paraffin wax so that no water can enter it, then submerged to measure the volume it displaces.
Your original — page 2
Weighing the clod before (W₁) and after (W₂) waxing gives the weight, then volume, of wax applied.
Your original — page 2
The waxed clod is submerged in the displacement can, filled level to the spout; the overflow water collected in the jar gives Vwater = volume of (soil + wax).
W1 is the original (un-waxed) weight of the clod — the wax is only a temporary waterproof coating used to measure volume, so it must not be included in the weight used for γt.
Core cutter method and sand replacement method are destructive testing — both require digging out and removing a sample of soil from the ground. Radiation method, by contrast, is non-destructive testing — the density is measured in place without removing any soil.
A thin rubber membrane at the base of a calibrated density meter is pressed onto a hole dug in the soil and expanded with water under a small constant pressure, so the balloon takes up the exact shape of the hole. The drop in the water level inside the calibrated meter (initial reading minus final reading) gives the volume of the hole directly, the same role V1−2V2+V3 plays in the sand replacement method. γt = W/V is then applied using the weight of soil excavated from that hole. It is generally suitable for well-compacted soils and not recommended for very soft soils that deform under the balloon's pressure.
A gamma-ray source and a detector are used together: in direct transmission mode a source rod is lowered into a small pre-drilled hole and gamma photons travel through the soil to a detector at the surface, while in backscatter mode the source stays near the surface and the count of photons scattered back is measured. Either way, the count rate is calibrated against known densities, so density is read essentially instantly with no excavation — which is exactly why it is the one non-destructive method in this list (per ASTM D6938).