Geotechnical Engineering / Soil Mechanics
This is performed for fine-grained soil (particle size < 75μ), and two methods are adopted: (1) pipette method, (2) hydrometer method.
500 g of soil is uniformly mixed into 1 litre of suspension.
For a 10 mL volume pipette sample: 5 g of particles will come out at t = 0 (as all particles are present at this instant, uniformly distributed).
At t = t0, the particle d is that particle having a settling velocity greater than H/t0 — i.e. it has already settled from height H by time t0.
50 g of soil (< 425μ) is taken and added with sufficient water to make 1 litre of soil suspension. From a fixed height H, 10 mL of sample is taken and dried to obtain the weight; thus concentration at t = 0 becomes known. The sample is allowed to settle, and from the same height H, 10 mL of sample is again taken (after elapsed time t0) and dried to obtain the weight and hence the new concentration.
γs = Gs·γw, μ = dynamic viscosity.
For samples taken at different times from the same height H, the size of the particle d and the corresponding % finer can be obtained. Thus the grain size distribution curve is plotted.
A sample of dry soil (Gs = 2.68) weighing 125 g is uniformly dispersed in water to form 1 litre of suspension. Determine: (1) the unit weight of suspension immediately after preparation. (2) 10 mL of suspension was removed from depth of 20 cm after a time of 2.5 min; the dry weight of sample in suspension drawn was found to be 0.398 g — determine a single point on the grain size curve for this observation. μ = 8.36 millipoise, γw = 0.9963 g/cc.
Approach: we know volume of water but need weight of water — the path is weight of solid → volume of solid → volume of water → weight of water.
The single grain-size-distribution-curve point obtained from this observation: 31.84% finer than the source's stated particle size.
Adding and subtracting Vsγw in the numerator:
The hydrometer's stem reading Rh is calibrated to give the specific gravity of the liquid it floats in.
Substituting the derived unit-weight-of-suspension formula for γ:
A hydrometer is used to find out the density of some liquid; from the density, the concentration of the liquid suspension can be found out.
In this case, He will not be constant, because the hydrometer gives the density of soil suspension at depth He, which corresponds to the centre of the bulb of the hydrometer — and that depth changes as the hydrometer sinks less deeply while suspension density falls over time.
Left: effective depth He to the hydrometer bulb centre A, in a plain jar. Right: the calibration geometry — RA is the reading level, H is the distance down to the bulb top, h is the bulb height, and Vh/Aj corrects for the volume the immersed hydrometer itself displaces (raising the suspension level).
Rh → H, through calibration (will be given in the question). Vh → volume of hydrometer = volume of bulb.
Deflocculating agent used: sodium hexametaphosphate.
Meniscus correction is always positive — the reading is taken at the top of the meniscus (where the stem is actually visible above the opaque suspension), which reads lower than the true liquid surface, so a fixed positive correction is added.
If temperature of testing is greater than the calibrated temperature, the correction will be positive. If temperature of testing is less than the calibration temperature, the correction will be negative.
To ensure that particles do not collide or join together, we add a deflocculating agent, which increases the density of the soil suspension. Hence the reading will increase. To correct for that, the correction has to be negative.
| Correction | Condition | Sign |
|---|---|---|
| Meniscus | always | +ve |
| Temperature | T > 27°C | +ve |
| T < 27°C | −ve | |
| Deflocculating agent | always | −ve |