Structural Steel Design / Built-up Compression Members / Part 2 of 2

Compression Members using LSM

Converted from handwritten notes — Steel Structure 4.pdf, pages 19–54

Doc No.SS-04-02
StatusDraft — Awaiting Review
Converted17-08-2026
Approved—

Compression Member using LSM — Buckling Classes

A common hot-rolled section and a built-up section having an axis of symmetry are assumed to have flexural buckling. The buckling strength of these members is affected by:

  1. (a) Residual stress
  2. (b) Initial bow
  3. (c) Incidental (accidental) eccentricity

To account for these factors, a large number of tests were conducted and column buckling classes (a, b, c, d) were established. The various types of cross-sections are classified according to the buckling classes a, b, c & d.

88.7 Euler's Stress λ →

Euler's (elastic) buckling stress vs. slenderness λ — theoretical curve (dashed) vs. the actual capped-off behaviour (solid), which the buckling-class curves below approximate.

a b c d fcd λ →

fcd–λ curves for buckling classes a through d — class a has the least imperfection sensitivity (highest capacity), class d the most.

Cross-sectionLimitsBuckling about axisBuckling class
Rolled I-sectionh/bf > 1.2, tf ≤ 40zz (xx)a
yyb
40 ≤ tf ≤ 100xxb
yyc
Rolled I-sectionh/bf ≤ 1.2, tf ≤ 100 mmxxb
yyc
Channel, angle, T & solid sections——c
Rolled I-sectionh/bf ≤ 1.2, tf > 100 mmxxd
yyd

Built-up members

All built-up members → buckling class C, except welded I-section and welded box section.

y y h b tf

Welded I-section: tf ≥ 40 mm → xx=b, yy=c. tf < 40 mm → xx=c, yy=d.

y y h b

Welded box section — generally class b. If b/tf < 30 and h/tw < 30 (thick weld), both xx and yy = c.

Design Compressive Strength & Section Classification

Pd=Aefcd

Ae → effective sectional area (gross area).

Deductions from the gross area If some hole has been made and it is not filled up, effective area will be (gross area − hole area), i.e. (Ag − d′t). If the section is slender, effective area is calculated by deducting the width of the compression plate in excess of the semi-compact section limit.

Classification of cross-section

A plate element of the c/s may buckle locally due to compressive stress. This local buckling can be avoided before the limit state is achieved by limiting the (b/t) ratio of each element of the section subjected to axial force, moment or shear. On the basis of the chances of buckling, four classes of cross-section are defined:

  1. (a) Plastic section
  2. (b) Compact section
  3. (c) Semi-compact section
  4. (d) Slender section

Plastic section — a section which can develop a plastic hinge, and before plastic failure mechanism, if local buckling of flange or web plate does not occur, the section is said to be a plastic section.

Compact section — section which can develop a plastic hinge but before the collapse mechanism is achieved, local buckling occurs, then the section is called a compact section.

θ₁ θ₂ Mp M θ →

In plastic sections, rotational capacity is greater than 6 times the rotation corresponding to formation of hinge (θ₂ > 6θ₁). Compact sections satisfy θ₂ < 6θ₁.

Semi-compact section — section which can develop yield moment (My) before local buckling occurs.

Slender section — section which will have local buckling even before the yielding moment develops.

If different elements of the c/s fail under different classes, the overall classification will be based on the lower class.

Internal vs. external (outstanding) elements

outstanding/external internal all are internal elements

I-section: flange overhang is external/outstanding, web is internal. Box section: all faces are internal elements.

ElementRatioPlasticCompactSemi-compact
Outstanding element of compression flange, rolled sectionb/tf9.4ε10.5ε15.7ε
Outstanding element of compression flange, welded sectionb/tf8.4ε9.4ε13.6ε
Internal element of compression flange, compression due to bendingb/tf29.3ε33.5ε42ε
Internal element of compression flange, axial compressionb/tf——42ε
Web of I, H / Box section, axial compressiond/tw——42ε
Web of channeld/tw42ε42ε42ε
Angles, compression due to bendingb/t, d/t9.4ε10.5ε15.7ε
Single/double angle, components separated, axial compressionb/t, d/t, (b+d)/t——15.7ε, 15.7ε, 25ε
Outstanding leg of angle in back-to-back double-angle memberd/t9.4ε10.5ε15.7ε
Internal element of the compression flange For an internal element b′ of the compression flange bounded by two webs (e.g. a box girder top flange), b′/tf ≤ 15.7ε for semi-compact classification; the internal element between webs b′/tw ≤ 42ε for all classes.

Flexural Buckling — Perry-Robertson Formula

For flexural buckling strength, we generally use the Perry-Robertson formula for calculation of fcd.

fcd=fy/γmoφ+φ2−λe2=χfyγmo≤fyγmo

χ → stress reduction factor.

χ=1φ+φ2−λe2 φ=0.5[1+α(λe−0.2)+λe2] λe=fyfcc≈λ88.8 fcc=π2Eλ2

α → imperfection factor, depends on buckling class.

Buckling classabcd
α0.210.340.490.76
fcd=f(λ,E,fy,α) (LSM) fac=f(fy,E,λ) (WSM)
Notes on fcd and column design For a given grade of steel, fcd will be a function of λ and α (a buckling-class table of λ vs. fcd is provided in the IS code / given in problems). For column design, generally we use plastic and compact sections, because they provide more stiffness. Effective length of compression members is calculated using the same recommendation as that in WSM.

Angle Struts

The compression in a single angle may be transferred either concentrically to its centroid through an end gusset, or by connecting one of its legs to the gusset or the adjoining member (eccentric connection).

Concentric connection

When a single angle is concentrically loaded, design should be done as per the flexural buckling formula already discussed:

fcd=fy/γmoφ+φ2−λe2 λ=ℓeffrmin

for single angle: rmin = rvv (about the vv axis).

In the formula for fcd, the value of α is taken corresponding to buckling class C (α = 0.49 for class 'c').

NOTE: if the value of λe comes out to be less than 0.2, take λe = 0.2.

Eccentric connection

When a single angle is connected through one leg, i.e. eccentrically loaded, we use the limit state of flexural-torsional buckling. Flexural-torsional buckling strength of a single angle loaded in compression through one of its legs is evaluated by taking equivalent slenderness ratio:

λe=k1+k2λvv2+k3λφ2

λe ≠ √(fy/fcc) in this case — this value of λe is used directly in the expression for φ.

φ=0.5[1+α(λe−0.2)+λe2]

k1, k2 and k3 are constants depending on end condition (k1 < k2 < k3).

λvv=ℓ/rvvεπ2E250=ℓ/rvv88.8

ε = √(250/fy).

λφ=(b1+b22t)/π2Efy

ℓ = c/c distance between supports; b₁, b₂ = leg widths of the angle, t = leg thickness.

b₁ b₂ t

Angle leg widths b₁ and b₂ (measured to the outer corner), thickness t.

Bolts at endGusset/member fixingk₁k₂k₃
≥ 2Fixed0.20.3520
Hinged0.70.65
1Fixed0.750.3520
Hinged1.250.5060

k₃ = 20 also applies for welded connections. In case of a welded strut, the values of k₁, k₂ and k₃ will be taken corresponding to the fixed condition and ≥ 2 bolts.

Double angle strut

Conditionℓefffcd
1. Discontinuous, < 2 bolts or welds(0.7–0.85)ℓ for in-plane buckling; ℓ for out-of-plane bucklingcalculated using flexural buckling formula
2. Continuous(0.7–1)ℓ for in-plane buckling; ℓ for out-of-plane bucklingcalculated using flexural buckling formula
3. Double angle, discontinuousℓeff = ℓcalculated using flexural-torsional buckling formula (as discussed earlier for single angles)

Load carrying capacity would be twice the load carrying capacity for a single angle. Since the critical condition is always out-of-plane buckling, hence we will always take ℓeff = ℓ.

Recommendation for tacking rivets for two members placed back to back are the same as in case of WSM, like:

λindividual≤40 ≤0.6λ (whole)

Design Steps for Compression Member (LSM)

  1. Find factored load.
  2. Assume slenderness ratio λ:
Section typeλ assumed
Single angle, double angle, single channel∈ (100, 150)
Double channel∈ (40, 80)
Single I-section∈ (80, 150)
Double I-section∈ (30, 60)

λchosen should never be greater than λmax. λmax is the same as recommended in WSM.

  1. Calculate fcd, by assuming buckling class and choosing the trial section. Check if fcd value satisfies the condition:
fcd×Agross>γf×P
Shortcut for choosing fcd Instead of choosing the value of λ, we may directly choose the fcd value between 0.4fy to 0.6fy.

Worked Example — Check Safety of a Compound (I+Channel) Section

A section formed from an I-section (240 mm wide flange, 8 mm thick) built up with an ISMC175 channel (90 mm from web to channel centroid). ℓeff = 6 m, Ac/s = 6796 mm², applied load = 600 kN. Check the safety in compression (LSM).

ISMC175 90 mm 240 mm t = 8 mm

240×8 mm plate combined with an ISMC175 channel offset 90 mm from the web centreline. Ixx = 1223 cm⁴, Iyy = 121 cm⁴ (properties of the ISMC175 given separately); Cyy = 22 mm.

fcd×6796≥γf×600 kN

γf = 1.5

fcd≥132.43 MPa
λe=fy(π2E/λ2)=250π2×2×105×λ=λ88.8

Since it is a built-up section, we take α = 0.49 (buckling class C).

Imin=min{Ixx,Iyy}=33.5243×106 mm⁴ rmin=IminA=70.235 mm λ=600070.235=85.42 λe=85.4288.8=0.9616
φ=0.5{1+0.49×0.761+0.9612}=1.148 χ=11.148+1.1482−0.9612=0.563 fcd=χ×2501.1=0.562×2501.1
fcd=127.92 MPa<132.43 MPa NOT SAFE.

Worked Example — Continuous Principal Rafter, 2 ISA90×90×8

A continuous principal rafter of a truss is 3 m between intermediate connections. It comprises 2 ISA90×90×8 connected on both sides of a 16.0 mm thick gusset plate. The two angle sections are tack riveted using 16 mm thick washers along the length at 300 mm intervals. Calculate the safe load that can be taken up by the rafter.

ISA90×90×8 16 mm gusset

Two ISA90×90×8 angles back-to-back on either side of a 16 mm gusset plate. A = 1379 mm² per angle, Cxx = Cyy = 25.1 mm, rxx = ryy = 27.5 mm, ruu = 34.7 mm, rvv = 17.5 mm.

fcd×Agrossγf=Psafe

Agross = 2 × 1379 mm², γf = 1.5.

Since the angles are symmetric about the gusset plate, we use the flexural buckling formula. Ixx ≤ Iyy, so Imin = Ixx,combine = 2Ixx,one — buckling will occur about the xx axis; this is the case of in-plane buckling. Effective length for a continuous rafter is (0.7–1)ℓ; we take the worst case ℓeff = ℓ.

ℓeff=ℓ=3000 mm rmin=2Ixx,one2Aone=rxx,one=27.5 mm
λ=300027.5=109.09 λe=109.0988.8=1.228 φ=0.5[1+0.49(1.028)+1.2282]=1.5065
χ=1φ+φ2−λe2=0.4202 fcd=χ×fyγmo=0.4202×2501.1
fcd=95.516 MPa
Psafe=95.516×2×13791.5
Psafe=175.62 kN

Check for local buckling

ℓtrvv≤40 and ≤0.6×λ (whole) 30017.5=17.14≤40, ≤0.6×109.09
OK — safe in local buckling.

Worked Example — ISA100×100×6 Strut, Eccentric (Flexural-Torsional Buckling)

An ISA100×100×6 is used as a strut in a truss. The length of the strut between intersection at each end is 3 m. Calculate the strength of the strut if it is connected by two bolts at each end and consider the end to be fixed.

ISA100×100×6

A = 1167 mm², Ixx = Iyy = 111.3 cm⁴, rxx = ryy = 30.9 mm, ruu = 39.1 mm, rvv = 19.5 mm.

As the single angle is connected to the gusset plate through one leg, it is the case of flexural-torsional buckling.

Strength=fcd×Agross (1167 mm²) λe=k1+k2λvv2+k3λφ2

k₁ = 0.2, k₂ = 0.35, k₃ = 20 for two bolts, fixed condition.

λvv=ℓ/rvv88.8=3000/19.588.8=1.732 λφ=(b1+b2)/2t88.8=(100+100)/(2×6)88.8=0.1876
λe=0.2+0.35×1.7322+20×0.18762=1.397

Buckling class C → α = 0.49.

φ=0.5{1+0.49×1.197+1.3972}=1.77 χ=1φ+φ2−λe2=0.3499
fcd=fyγmo×χ
fcd=79.43 MPa
Strength of ISA100×100×6=fcd×Ag=79.43×1167=92.69 kN
Safe strength=92.691.5=61.79 kN

Worked Example — Built-up Double-Channel Column (2 ISMC300, Pin-ended)

Design a built-up section to carry an axial load of 750 kN. The effective length of column is 10 m; use two channels placed back to back.

factored load=750×1.5=1125 kN

Adopt λ = 80. Buckling class = C, because it is a built-up section, α = 0.49.

λfcd (MPa)
60168
70152
80136
90121
100107

(Buckling class C, fy = 250 MPa given.) For λ = 80, fcd = 136 MPa.

Agross required=1125×103136=8272.05 mm²

Area of one channel required = 4136 mm².

Adopt 2 nos of ISMC300 (Aprovided = 2 × 4564 = 9128 mm² > 8272.05 mm² — OK).

Check for safety

y y

Two channels placed at a spacing such that rxx,combine = ryy,combine.

rmin=rxx,combine=rxx,one=118.1 mm λ=10000118.1=84.674<180 (limit for λmax) OK
fcd=128.98 N/mm² (by interpolation) load carrying capacity=fcd×Agross=128.98×9128
=1177.32 kN>1125 kN OK — safe.
Effective length increase for laced columns As per the recommendation for laced columns, effective length needs to be increased by 5%.
λ=84.674×1.05=88.90 fcd=136−1510×8.9=122.65 N/mm² load carrying capacity=122.65×2×4564=1119.54 kN<1125 kN
NOT SAFE, once the 5% laced-length increase is applied.

Built-up Compression Member using Lacing (LSM)

All the recommendations for lacing discussed in WSM are valid for LSM, except that slenderness ratio is taken 5% more than that recommended in the table.

ℓeff = ℓ ℓeff = 0.8ℓ ℓeff = 0.65ℓ

Effective length for battened column end conditions: hinged-hinged (ℓ), hinged-fixed (0.8ℓ), fixed-fixed (0.65ℓ). In a battened column, effective length is taken 10% more than this.

Check for tension in lacing

1.7d₀ d₀ b, t F

Lacing bar with a single hole of diameter d₀, end distance 1.7d₀.

V=2.5×γf×P100 F=V2sinθ
(b−d0)t=Anet (b−d0)t0.9fuγm1≥V2sinθ — (1) btfyγmo≥V2sinθ — (2)

Check for compression in lacing

λ=ℓefft/12≤145 — (1)

ℓeff = ℓ for single lacing, 0.7ℓ for double lacing.

Buckling class for lacing = C, α = 0.49 — interpolate a λ–fcd table:

fcd×b×t≥V2sinθ

In case of batten (LSM)

Check for shear:

(VC/2ℓ)D×t≤min{fu/3γm1, fy/3γmo}
Why we always check for yielding In case of compression members, we generally do not reach the value of the ultimate stage. Hence we should always check for yielding conditions.
(VC/4)(tD2/6)≤fyγmo

Worked Example — Design Lacing for a 2 ISMC350 Column (LSM)

Design compression member to carry axial load of 750 kN. The section may be two channels placed back to back. The length of column is 10 m, and it is hinged at the two ends. Design lacing for connecting the two components.

ℓeff=1.05(ℓ)=10.5 m

Assume λ = 80.

λfcd (MPa)
60168
70152
80136
90121
100107
11094.6
12083.7

(For fy = 250 MPa, buckling class C.) Since two channels are used back to back, we have symmetry, so we use the flexural buckling formula.

λ=80→fcd=136 MPa Agross required=γfP136=1.5×750×103136=8272.05 mm²

Adopt ISMC350 (2 nos) back to back. For ISMC350: A = 5366 mm², Ixx = 1008 cm⁴, Iyy = 430.6 cm⁴, rxx = 136.6 mm, ryy = 28.3 mm, Cyy = 24.4 mm, g = 60 mm.

We will adopt spacing such that ryy = rxx ⇒ rmin = (rxx)one = 136.6 mm.

λ=10500136.6=76.86 fcd=141.013 N/mm² (table interpolation)
fcd×Ag=141.013×2×5366
=1513.36 kN>1.5×750 kN OK

Calculation of spacing

Ixx,c=Iyy,c 2×1008×104=2×430.6×104+2×5366(24.4+s2)2
s=218.47 mm⇒adopt spacing=220 mm

ryy > rxx.

Design for lacing

θ=45° ℓ

Let's adopt single lacing with θ = 45° (assumed).

ℓ=220+2×60=340 mm C=2×ℓ=680 mm Crmin (one)=68028.3=24.028≤50, ≤0.7×76.86
OK — safe in local buckling, no requirement of double lacing.
V=2.5×1.5×750×103100=28.125 kN Flacing=V2sinθ=28.1252×1/2=19.87 kN

Adopt bolt dia = 22 mm of property class 4.6. Dia of hole = 24 mm (d0). bmin = 66 mm (3×bolt dia) ⇒ adopt b = 70 mm.

t=ℓ40 (single lacing)=340240=12.02 mm⇒adopt t=12 mm λ=350212/2=138.79<145 OK

Check for compression & tension

λfcd (MPa)
13074.3
14066.2
for λ=138.79, buckling class C⇒fcd=67.34 N/mm² fcd×b×t=67.34×12×70=56.55 kN>19.87 kN
OK — safe in compression.
(b−d0)t×0.9fuγm1>19.87×103 N (70−24)×12×0.9×4101.25=162.95 kN>19.87 kN OK fyγmo×b×t=250×70×12=190.2 kN>19.87 kN OK
Safe in tension.

Design for connection

Design force=Vcotθ=28.125×1=28.125 kN

Bolt value = min{shearing strength, bearing strength}. Assuming shear plane passes through shank.

Vdsb=fub3×1γm1×π4×d2=4003×11.25×π4×222

(βlj = βlg = βpk = 1.)

Vdsb=70.23 kN
Vdpb=2.5kbdtfuγm1 kb=min{e3d0,p3d0−0.25,fubfu,1}=(0.566,0.513,0.97,1)

e = 1.7d0, p = 2.5d assumed — adopt kb = 0.513. Flange thickness tf = 13.5 mm.

Vdpb=2.5×0.513×22×12×4101.25
Vdpb=111.24 kN
bolt value=min{70.23,111.24}=70.23 kN no. of bolt required=28.12570.23<1
Adopt 1 bolt (22 mm dia).