Structural Steel Design / Built-up Compression Members / Part 2 of 2
A common hot-rolled section and a built-up section having an axis of symmetry are assumed to have flexural buckling. The buckling strength of these members is affected by:
To account for these factors, a large number of tests were conducted and column buckling classes (a, b, c, d) were established. The various types of cross-sections are classified according to the buckling classes a, b, c & d.
Euler's (elastic) buckling stress vs. slenderness λ — theoretical curve (dashed) vs. the actual capped-off behaviour (solid), which the buckling-class curves below approximate.
fcd–λ curves for buckling classes a through d — class a has the least imperfection sensitivity (highest capacity), class d the most.
| Cross-section | Limits | Buckling about axis | Buckling class |
|---|---|---|---|
| Rolled I-section | h/bf > 1.2, tf ≤ 40 | zz (xx) | a |
| yy | b | ||
| 40 ≤ tf ≤ 100 | xx | b | |
| yy | c | ||
| Rolled I-section | h/bf ≤ 1.2, tf ≤ 100 mm | xx | b |
| yy | c | ||
| Channel, angle, T & solid sections | — | — | c |
| Rolled I-section | h/bf ≤ 1.2, tf > 100 mm | xx | d |
| yy | d |
All built-up members → buckling class C, except welded I-section and welded box section.
Welded I-section: tf ≥ 40 mm → xx=b, yy=c. tf < 40 mm → xx=c, yy=d.
Welded box section — generally class b. If b/tf < 30 and h/tw < 30 (thick weld), both xx and yy = c.
Ae → effective sectional area (gross area).
A plate element of the c/s may buckle locally due to compressive stress. This local buckling can be avoided before the limit state is achieved by limiting the (b/t) ratio of each element of the section subjected to axial force, moment or shear. On the basis of the chances of buckling, four classes of cross-section are defined:
Plastic section — a section which can develop a plastic hinge, and before plastic failure mechanism, if local buckling of flange or web plate does not occur, the section is said to be a plastic section.
Compact section — section which can develop a plastic hinge but before the collapse mechanism is achieved, local buckling occurs, then the section is called a compact section.
In plastic sections, rotational capacity is greater than 6 times the rotation corresponding to formation of hinge (θ₂ > 6θ₁). Compact sections satisfy θ₂ < 6θ₁.
Semi-compact section — section which can develop yield moment (My) before local buckling occurs.
Slender section — section which will have local buckling even before the yielding moment develops.
I-section: flange overhang is external/outstanding, web is internal. Box section: all faces are internal elements.
| Element | Ratio | Plastic | Compact | Semi-compact |
|---|---|---|---|---|
| Outstanding element of compression flange, rolled section | b/tf | 9.4ε | 10.5ε | 15.7ε |
| Outstanding element of compression flange, welded section | b/tf | 8.4ε | 9.4ε | 13.6ε |
| Internal element of compression flange, compression due to bending | b/tf | 29.3ε | 33.5ε | 42ε |
| Internal element of compression flange, axial compression | b/tf | — | — | 42ε |
| Web of I, H / Box section, axial compression | d/tw | — | — | 42ε |
| Web of channel | d/tw | 42ε | 42ε | 42ε |
| Angles, compression due to bending | b/t, d/t | 9.4ε | 10.5ε | 15.7ε |
| Single/double angle, components separated, axial compression | b/t, d/t, (b+d)/t | — | — | 15.7ε, 15.7ε, 25ε |
| Outstanding leg of angle in back-to-back double-angle member | d/t | 9.4ε | 10.5ε | 15.7ε |
For flexural buckling strength, we generally use the Perry-Robertson formula for calculation of fcd.
χ → stress reduction factor.
α → imperfection factor, depends on buckling class.
| Buckling class | a | b | c | d |
|---|---|---|---|---|
| α | 0.21 | 0.34 | 0.49 | 0.76 |
The compression in a single angle may be transferred either concentrically to its centroid through an end gusset, or by connecting one of its legs to the gusset or the adjoining member (eccentric connection).
When a single angle is concentrically loaded, design should be done as per the flexural buckling formula already discussed:
for single angle: rmin = rvv (about the vv axis).
In the formula for fcd, the value of α is taken corresponding to buckling class C (α = 0.49 for class 'c').
When a single angle is connected through one leg, i.e. eccentrically loaded, we use the limit state of flexural-torsional buckling. Flexural-torsional buckling strength of a single angle loaded in compression through one of its legs is evaluated by taking equivalent slenderness ratio:
λe ≠ √(fy/fcc) in this case — this value of λe is used directly in the expression for φ.
k1, k2 and k3 are constants depending on end condition (k1 < k2 < k3).
ε = √(250/fy).
ℓ = c/c distance between supports; b₁, b₂ = leg widths of the angle, t = leg thickness.
Angle leg widths b₁ and b₂ (measured to the outer corner), thickness t.
| Bolts at end | Gusset/member fixing | k₁ | k₂ | k₃ |
|---|---|---|---|---|
| ≥ 2 | Fixed | 0.2 | 0.35 | 20 |
| Hinged | 0.7 | 0.6 | 5 | |
| 1 | Fixed | 0.75 | 0.35 | 20 |
| Hinged | 1.25 | 0.50 | 60 |
k₃ = 20 also applies for welded connections. In case of a welded strut, the values of k₁, k₂ and k₃ will be taken corresponding to the fixed condition and ≥ 2 bolts.
| Condition | ℓeff | fcd |
|---|---|---|
| 1. Discontinuous, < 2 bolts or welds | (0.7–0.85)ℓ for in-plane buckling; ℓ for out-of-plane buckling | calculated using flexural buckling formula |
| 2. Continuous | (0.7–1)ℓ for in-plane buckling; ℓ for out-of-plane buckling | calculated using flexural buckling formula |
| 3. Double angle, discontinuous | ℓeff = ℓ | calculated using flexural-torsional buckling formula (as discussed earlier for single angles) |
Load carrying capacity would be twice the load carrying capacity for a single angle. Since the critical condition is always out-of-plane buckling, hence we will always take ℓeff = ℓ.
Recommendation for tacking rivets for two members placed back to back are the same as in case of WSM, like:
| Section type | λ assumed |
|---|---|
| Single angle, double angle, single channel | ∈ (100, 150) |
| Double channel | ∈ (40, 80) |
| Single I-section | ∈ (80, 150) |
| Double I-section | ∈ (30, 60) |
λchosen should never be greater than λmax. λmax is the same as recommended in WSM.
A section formed from an I-section (240 mm wide flange, 8 mm thick) built up with an ISMC175 channel (90 mm from web to channel centroid). ℓeff = 6 m, Ac/s = 6796 mm², applied load = 600 kN. Check the safety in compression (LSM).
240×8 mm plate combined with an ISMC175 channel offset 90 mm from the web centreline. Ixx = 1223 cm⁴, Iyy = 121 cm⁴ (properties of the ISMC175 given separately); Cyy = 22 mm.
γf = 1.5
Since it is a built-up section, we take α = 0.49 (buckling class C).
A continuous principal rafter of a truss is 3 m between intermediate connections. It comprises 2 ISA90×90×8 connected on both sides of a 16.0 mm thick gusset plate. The two angle sections are tack riveted using 16 mm thick washers along the length at 300 mm intervals. Calculate the safe load that can be taken up by the rafter.
Two ISA90×90×8 angles back-to-back on either side of a 16 mm gusset plate. A = 1379 mm² per angle, Cxx = Cyy = 25.1 mm, rxx = ryy = 27.5 mm, ruu = 34.7 mm, rvv = 17.5 mm.
Agross = 2 × 1379 mm², γf = 1.5.
Since the angles are symmetric about the gusset plate, we use the flexural buckling formula. Ixx ≤ Iyy, so Imin = Ixx,combine = 2Ixx,one — buckling will occur about the xx axis; this is the case of in-plane buckling. Effective length for a continuous rafter is (0.7–1)ℓ; we take the worst case ℓeff = ℓ.
An ISA100×100×6 is used as a strut in a truss. The length of the strut between intersection at each end is 3 m. Calculate the strength of the strut if it is connected by two bolts at each end and consider the end to be fixed.
A = 1167 mm², Ixx = Iyy = 111.3 cm⁴, rxx = ryy = 30.9 mm, ruu = 39.1 mm, rvv = 19.5 mm.
As the single angle is connected to the gusset plate through one leg, it is the case of flexural-torsional buckling.
k₁ = 0.2, k₂ = 0.35, k₃ = 20 for two bolts, fixed condition.
Buckling class C → α = 0.49.
Design a built-up section to carry an axial load of 750 kN. The effective length of column is 10 m; use two channels placed back to back.
Adopt λ = 80. Buckling class = C, because it is a built-up section, α = 0.49.
| λ | fcd (MPa) |
|---|---|
| 60 | 168 |
| 70 | 152 |
| 80 | 136 |
| 90 | 121 |
| 100 | 107 |
(Buckling class C, fy = 250 MPa given.) For λ = 80, fcd = 136 MPa.
Area of one channel required = 4136 mm².
Adopt 2 nos of ISMC300 (Aprovided = 2 × 4564 = 9128 mm² > 8272.05 mm² — OK).
Two channels placed at a spacing such that rxx,combine = ryy,combine.
All the recommendations for lacing discussed in WSM are valid for LSM, except that slenderness ratio is taken 5% more than that recommended in the table.
Effective length for battened column end conditions: hinged-hinged (ℓ), hinged-fixed (0.8ℓ), fixed-fixed (0.65ℓ). In a battened column, effective length is taken 10% more than this.
Lacing bar with a single hole of diameter d₀, end distance 1.7d₀.
ℓeff = ℓ for single lacing, 0.7ℓ for double lacing.
Buckling class for lacing = C, α = 0.49 — interpolate a λ–fcd table:
Check for shear:
Design compression member to carry axial load of 750 kN. The section may be two channels placed back to back. The length of column is 10 m, and it is hinged at the two ends. Design lacing for connecting the two components.
Assume λ = 80.
| λ | fcd (MPa) |
|---|---|
| 60 | 168 |
| 70 | 152 |
| 80 | 136 |
| 90 | 121 |
| 100 | 107 |
| 110 | 94.6 |
| 120 | 83.7 |
(For fy = 250 MPa, buckling class C.) Since two channels are used back to back, we have symmetry, so we use the flexural buckling formula.
Adopt ISMC350 (2 nos) back to back. For ISMC350: A = 5366 mm², Ixx = 1008 cm⁴, Iyy = 430.6 cm⁴, rxx = 136.6 mm, ryy = 28.3 mm, Cyy = 24.4 mm, g = 60 mm.
We will adopt spacing such that ryy = rxx ⇒ rmin = (rxx)one = 136.6 mm.
ryy > rxx.
Let's adopt single lacing with θ = 45° (assumed).
Adopt bolt dia = 22 mm of property class 4.6. Dia of hole = 24 mm (d0). bmin = 66 mm (3×bolt dia) ⇒ adopt b = 70 mm.
| λ | fcd (MPa) |
|---|---|
| 130 | 74.3 |
| 140 | 66.2 |
Bolt value = min{shearing strength, bearing strength}. Assuming shear plane passes through shank.
(βlj = βlg = βpk = 1.)
e = 1.7d0, p = 2.5d assumed — adopt kb = 0.513. Flange thickness tf = 13.5 mm.