Energy-Depth Relationship

V₁²/2g y₁ V₂²/2g y₂ TEL Q: constant

Energy depth relationship along a channel of varying bed elevation, constant Q

E1=y1+V122g,  E2=y2+V222g
E=ycosθ+V22g

General case (large slope). In this course we normally take cosθ ≈ 1.

The E–y Curve for Increasing Discharge

y E → E = y (45°) (Q/B)₁ (Q/B)₂ (Q/B)₃ yₓ y₁ 45°

(Q/B)₃ > (Q/B)₂ > (Q/B)₁ — increasing discharge per unit width shifts the curve outward; each still has its own 45° and E-axis asymptotes

Rectangular Channel — General Cubic Form

y B
E=y+Q22gB2y2
E=y+(Q22gB2)1y2

Equation (A) — a cubic in y for a given E.

Cubic root count For a particular specific energy and Q/A, three values of y are possible as shown in equation (A) — a cubic equation. However, one of the y will be negative, and thus we will have two valid (positive) values of y possible: the alternate depths. At one particular discharge, for a given specific energy, two depths of flow are possible (y₁ and y₂); one corresponds to subcritical flow and the other corresponds to supercritical flow (y₁ < y₌).

Deriving the Critical Flow Condition

E=y+Q22gA2

Maximizing Q for fixed E: (E−y)⋅2gA² = Q², then dQ²/dy = 0:

(E−y)⋅2AdAdyg−2gA2=0
T dy T dy dA/dy = T

A thin strip of top width T and thickness dy near the free surface gives dA/dy = T for any cross-section shape

Q2gAdAdy=2gA2
Q2gA3T=1
Q2/A2g⋅A/T=1⇒V2gA/T=1⇒VgA/T=1
Fr=1  flow to be critical

Minimizing E for fixed Q gives the same condition:

dEdy=0⇒1+Q2g(−2)1A3dAdy=0
1−Q2gA3T=0⇒Q2TgA3=1⇒Fr=1

For critical condition:

(Ec−yc)=Ac2Tc

Since Q²T/gA³ = 1 at critical condition, so Q²/gA² = Ac/Tc.

Calculation of Critical Depth

Rectangular Channel

y B
Q2TgA3=1⇒Q2BgB3y3=1⇒Q2B2×1gy3=1
yc=(q2g)13,  q=QB
Ec=yc+Q22gAc2=yc+q22gyc2=yc+yc32yc2
Ec=32yc

For a rectangular channel.

Triangular Channel

1 m
A=my2
Q2⋅(2myc)g(myc2)3=1⇒2Q2gm2=yc5
yc=(2Q2gm2)15
Ec=yc+Q22gAc2=yc+gm2yc52×12g×1m2yc4
Ec=yc+yc4=5yc4
Ec=1.25yc

For a triangular channel.

Flow Transition — Hump Creation (Introduction)

TEL: constant (loss = 0) y₁ y₁−(y₂+Δz) y₂ Δz Q → E₁ E₂ width = constant

A smooth hump of height Δz reduces the specific energy at the crest to E₂ = E₁ − Δz, read as a leftward shift on the E–y curve

E2=E1−Δz