Geotechnical Engineering / Soil Mechanics
Shallow foundation transmits the structural load to a soil strata at relatively smaller depth.
Strip footing (wall footing, L>5B) and spread/column footing.
General requirement: for satisfactory performance, foundation must be safe against shear failure, and settlement of foundation (especially differential settlement) should be within permissible limit. Foundation must be located at such a depth that it is not affected by seasonal volume changes of soil and also by the presence of adjoining structures.
Basic footing terminology: load P, footing B×B, founding depth Df.
Gross loading intensity (unit weight of concrete taken equal to that of the soil):
Net loading intensity (in excess of what the soil was originally subjected to):
When the load is very heavy and soil is very weak (soft clay), a raft is constructed to such a depth that P/B² − γ·Df = 0 — the soil bears no net load at all. Such a raft is a fully compensated raft, and the foundation is called a floating foundation.
Ultimate bearing capacity qu — the maximum gross intensity of loading that soil can support before it fails in shear:
Net ultimate bearing capacity qnu:
Net safe bearing capacity qns and gross safe bearing capacity qs:
Safe bearing pressure qps — the maximum net intensity of loading that can be allowed on soil without the settlement exceeding permissible value. No factor of safety is used while dealing with settlement, because it has already been included in the permissible settlement.
Bearing capacity of soil is calculated on the basis of shear failure criterion. There are three modes of shear failure: (1) general shear failure, (2) local shear failure, (3) punching shear failure.
General shear failure: well-defined failure surface reaching the ground, with visible heaving/bulging on both sides.
Local shear failure: considerable compression under footing, only partial development of plastic equilibrium; failure surface does not reach the ground surface, and only slight heaving occurs. No tilting of foundation. Ultimate bearing capacity is not well defined on the load-settlement curve — found via the double tangent method. Occurs in sand for φ<29° and relative density 35–70%; in clays when UCS < 100 kN/m².
Punching shear failure: relatively high compression of soil under the footing, accomplished by shearing in the vertical direction around the edge of footing. No heaving of ground surface, no tilting occurs. Settlement is very high; occurs in soil which is highly compressible, particularly when foundation is located at considerable depth (e.g. pile foundations). Occurs in very loose sand when Dr<35%.
Terzaghi's failure mechanism: Zone I (elastic equilibrium, wedge below the footing, moves with it as part of the foundation), Zone II (radial shear), Zone III (Rankine passive zone).
Terzaghi's assumptions: (1) footing is a strip footing; (2) soil is homogeneous; (3) two-dimensional plane strain conditions prevail; (4) base of footing is rough; (5) Df/B ≤ 1; (6) loading is vertical and symmetrical; (7) general shear failure occurs; (8) ground is horizontal; (9) shearing resistance of soil between the ground surface and the base of footing is neglected; (10) footing is considered as a surface footing with a uniform surcharge of γDf at the base of footing; (11) shear strength of soil is governed by Mohr-Coulomb criteria.
Zone I is prevented from undergoing any lateral movement due to friction and adhesion between the base of footing and soil. It remains in an elastic state and is considered as part of the foundation. At failure, Zone I and the footing press Zone II and Zone III and transform them into a state of plasticity.
Valid for strip footing under general shear failure. q = γDf is the surcharge term.
For φ=0: Nc=5.7, Nq=1, Nγ=0. For clayey soil (φ=0):
Terzaghi's formula is actually valid for general shear failure. In case of local shear failure we use reduced strength parameters:
N′c, N′q, N′r = f(φℓ). In exam, it is only when φ<29° that we do modifications for local shear failure. For φ>29°, no modification. For φ ∈ (29°,36°), practically interpolate Nc,Nq,Nγ for both cases and go through the procedure.
Square:
Circular (B = diameter):
Rectangular:
Three water-table scenarios, each modifying the surcharge and the failure-zone weight terms.
(1) W.T. above/at the base of footing:
(2) W.T. between the base of footing and depth B below it (rise x above base):
(3) W.T. above the base of footing (depth y below GL, within Df):
Rw and Rw′ are water table correction factors for the 2nd and 3rd terms respectively in Terzaghi's equation, ranging linearly from 0.5 (W.T. at surface) to 1.0 (W.T. at or below the relevant depth):
where q = γtDf and Bγ = Bγt.
Applicable for saturated clayey soil only, with φu=0 (undrained angle of internal friction). This theory did not neglect the shear strength of soil above foundation level, hence it can be applied to even deeper foundations.
Nc = f(Df/B, shape of footing):
B = smaller dimension of the footing.
A 3 m square footing is located in dense sand at depth of 2 m. Determine the ultimate bearing capacity for water at: (a) ground surface, (b) footing level, (c) 1 m below footing level. c=0, φ=35°, Nq=33, Nγ=34. γt=18 kN/m³, γsat=20 kN/m³, γw=10 kN/m³.
Square footing formula (shape-modified, c=0):
(a) WT at GL: entire soil column submerged, γsub=10:
(b) WT at footing level: surcharge term uses γt, weight term uses γsub:
(c) WT 1 m below footing level: within depth B=3m, 1m is still γt, remaining 2m is γsub:
A square footing is located at depth 1.5 m from GL, carries a column load of 150 kN. Soil is submerged, γsub=11 kN/m³, φ=30°. Find the size of footing using Terzaghi's formula. For φ=30°: Nq=10, Nγ=6. FOS=3.
Assuming soil to have been filled back (net intensity = P/B²):
Df/B = 1.5/1.542 < 1, OK (satisfies the Df/B ≤ 1 Terzaghi assumption). If Df/B > 1 came out, we would provide Df = B instead.
A building is to be supported on raft foundation of dimension 14 m by 21 m. Subsoil is clay with average UCS of 15 kN/m². The pressure on soil due to weight of building and load it carries is 140 kN/m² at the base of raft. Building has provision for basement floor. At what depth should the bottom of raft be placed? Provide FOS of 3 against shear failure. γclay=19 kN/m³, use Skempton's approach.
Assuming Df/B < 2.5:
Df/B = 6.287/14 < 2.5, hence OK.
A strip footing carries 15000 kg/m, founded 1.2 m deep in clay. γsoil=1750 kg/m³, γconc=2500 kg/m³, cu=8500 kg/m², FOS=2. Find the width of footing.
Assuming Df/B<2.5:
Df/B = 1.2/0.486 = 2.47 < 2.5, OK.
s, d, i are shape, depth and inclination factors.
This approach can be applied for any depth of footing. Failure mechanism is considered the same as that of Terzaghi, but the failure surface is assumed to extend above the foundation level, and shear strength of soil above the base of footing is taken into account.
For φ=0: Nc=5.14, Nq=1, Nγ=0.
To account for eccentricity of loading, the footing dimension becomes concentric to the reduced dimension of footing. Thus instead of B we use (B−2ex), and in place of L we use (L−2ey):
Plate load test is used to calculate: (1) ultimate bearing capacity of soil, (2) allowable bearing pressure corresponding to permissible settlement, (3) settlement of the foundation itself.
Plate load test setup: a rigid plate (Bp×Bp) loaded via a hydraulic jack reacting against sand-bag kentledge, with settlement measured against load intensity.
Sand, square footing:
Clay:
For any shape other than square (c=0 sand):
e.g. Strip:
Applicable for sandy soil (since plate load gives immediate settlement); load intensity is same below foundation and plate:
This approach for calculating settlement is applicable when the testing had been done at the same level at which the foundation is located. However, if the foundation is located at greater depth and testing has been done at a shallower depth, correction to the settlement computed needs to be done:
D2 = difference in level between the test and the foundation.
In case testing has not been done at the level of footing, then the corrected Sf will be taken as permissible settlement, and from that Sp will be calculated, and this Sp will be used for calculating allowable bearing pressure as done before.
A plate load test on a sandy soil, with a test plate of size 60×60 cm, undergoes a settlement of 5 mm at a pressure of 12×104 N/m². What will be the expected settlement of a 3 m×3 m footing under the same pressure?
A load test conducted by putting a 60 cm square plate on top of a sandy deposit gave ultimate bearing capacity 60 kN/m². What is the ultimate bearing capacity for a strip footing of 1.2 m width?
Split-spoon sampler driven by a 65 kg hammer falling 75 cm; the first 150 mm of penetration is a seating drive (not recorded), and the SPT-N value is the blow count for the next 300 mm.
SPT-N value for the foundation should correspond to the average N value corresponding to the mid-depth between the base of footing and the depth 2B. Due to lesser overburden, the sample gets under-compacted, and hence correction is required for overburden.
&sigmā = effective stress at the level of test, in kN/m².
Dilatancy correction is applied to the value already corrected for overburden. It is applied only if N1>15, and only below the water table.
N1>15 basically represents a dense sand. Thus dilatancy correction is applied for dense sand located below the water table because in case of dense sand, due to impact loading, pore pressure developed is negative, which causes increase in shear strength, resulting in increase in penetration resistance. Thus, observed SPT value would be generally greater and hence needs to be reduced.
| N | Relative density (%) | φ |
|---|---|---|
| <4 | 0 | 25–32° |
| 4–10 | 15 | 27–32° |
| 10–30 | 65 | 30–35° |
| 30–50 | 85 | 35–40° |
| >50 | 100 | 38–48° |
Peck-Hanson formula:
N = SPT-N value, Sa = permissible settlement (mm). Cw = water table correction factor:
Dw is measured from top of the soil.
IS code formula for raft:
A strip footing 8 m wide is designed for total settlement of 40 mm. The safe bearing capacity (shear) was 150 kN/m², and safe allowable soil pressure was 100 kN/m². Due to importance of structure, the footing is now to be redesigned for a total permissible settlement of 25 mm. What will be the new width of footing?
Since qanet = 0.44 Cw·N·Sa is proportional to Sa for the same soil (N, Cw unchanged when only the settlement criterion is redesigned):
Primary and secondary consolidation can be calculated as discussed earlier (in the consolidation chapter), under the assumption of 1D consolidation. However, in reality consolidation generally will not be 1D. The immediate settlement is calculated using the theory of elasticity:
qn = net foundation pressure, B = width of footing (smaller dim.), μ = Poisson's ratio of soil, ES = modulus of elasticity of soil, If = influence factor depending on shape and rigidity of foundation.
Srigid = 0.8 Sflexible. In flexible footing, the contact pressure at the interface between footing and soil is uniformly distributed, and the footing itself deforms into a dished shape.
Rigid footing on clay: bowl-shaped (higher) contact pressure toward the centre. Rigid footing on sand: contact pressure peaks toward the edges (since sand near the edge is less confined and stiffer relative to the centre under a rigid plate).
When soil mass of a freshly placed fill or soft compressible deposit moves down relative to the pile, a downward drag is applied on the pile surface — this is called negative skin friction.
It can also develop in loose sand deposits. It also occurs due to lowering of ground water table.
Negative skin friction for a single pile is calculated in the same manner in which the frictional capacity of pile is calculated:
In case of a group of piles, negative skin friction is calculated as friction on the block + weight of soil in the block (clay):
Under-reamed piles are provided in case of expansive soil, and also when point-bearing resistance is to be increased. Diameter of bulb = 2 to 3 times diameter of shaft.
Pullout resistance of an under-reamed pile combines the shaft friction (πdL over each straight segment) and bearing resistance from the bulb's annular face.
Slopes classified as finite (limited extent, bounded by a toe and crest) and infinite (extends indefinitely, thin surface layer over a much deeper mass).
In case of finite slope, failure is a rotational failure and the failure surface is part of a circular arc, or a logarithmic spiral. However for analysis purposes, we assume the failure surface to be part of a circle.
Face failure occurs when the slope angle (β) is high and soil above the toe is weaker. Toe failure occurs when there is a homogeneous condition above or below the toe — the most common type, generally when β>53°.
When β<53°, or when soil below the toe is soft and weak, base failure occurs.
In case of infinite slope, failure occurs along a line parallel to the slope.
Slice of a dry cohesionless infinite slope, width b along the slope (base bcosβ horizontally), depth H.
h = depth of seepage (measured from the failure plane up to the phreatic surface). When h=H (fully seeped):
Find the FOS on an infinite slope, 10 m thick soil layer at β=30°, with the bottom 8 m saturated (seepage) and top 2 m dry. c=0, φ=35°, γd=16 kN/m³, γsat=20 kN/m³.
Locate the plane on which failure will occur: failure will not occur in the top 2 m, because in case of dry cohesionless soil, failure occurs only when β>φ; here β=30° but φ=35°, hence failure cannot occur in the top 2 m — the critical plane lies within the seeped zone, at depth h ≈ 0.867 m below the top of the seeped region (found by setting FOS=1 for a trial plane within that zone).
Layered slope: 1 m of soil ① over 3 m of soil ②, both cohesionless with different properties.
In these kinds of problems, if we've to locate the failure plane, we'll assume the failure plane once in soil ① and then in soil ②, and calculate the depth by equating FOS=1. The depth so obtained should satisfy the zone in which the failure plane has been assumed.
Clayey infinite slope, depth h to the failure plane.
Steady seepage: