Geotechnical Engineering / Soil Mechanics

Foundation Engineering — Bearing Capacity & Slope Stability

Converted from handwritten notes — 18 Soil mechanics.pdf, pages 1 to 44

Doc No.GEO-18
StatusDraft — Awaiting Review
Converted10-08-2026
Approved—

Types of Shallow Foundation

Shallow foundation transmits the structural load to a soil strata at relatively smaller depth.

1m (1) Strip footing (wall footing), L>5B B (2) Spread/column footing — square, rectangular, or circular

Strip footing (wall footing, L>5B) and spread/column footing.

  1. Combined footing — provided when the footing area of two columns overlaps.
  2. Mat/Raft foundation — if the summation of footing areas of all columns in a building adds up to greater than 50% of the total plan area of the building, we provide mat/raft foundation. Raft foundation covers the entire building and all columns rest on that mat. Other reasons for providing raft foundations: (a) when the soil is weak at shallow depth and there is some weak pocket of soil inside the building plan; (b) if there is greater chance of differential settlement.
  3. Strap footing — used near a property line, where an eccentric column footing is connected via a strap beam to an interior footing to balance the eccentric moment (loose sand is placed at the bottom of the strap beam so it doesn't bear directly on the soil).

General requirement: for satisfactory performance, foundation must be safe against shear failure, and settlement of foundation (especially differential settlement) should be within permissible limit. Foundation must be located at such a depth that it is not affected by seasonal volume changes of soil and also by the presence of adjoining structures.

Basic Terminology

P B × B Df

Basic footing terminology: load P, footing B×B, founding depth Df.

Gross loading intensity (unit weight of concrete taken equal to that of the soil):

qg=PB2+γsoil⋅Df

Net loading intensity (in excess of what the soil was originally subjected to):

qn=PB2  (when backfilling is done) qn=PB2−γsoil×Df  (when no backfilling, e.g. basement construction)
P Basement

When the load is very heavy and soil is very weak (soft clay), a raft is constructed to such a depth that P/B² − γ·Df = 0 — the soil bears no net load at all. Such a raft is a fully compensated raft, and the foundation is called a floating foundation.

Bearing Capacity Definitions

Ultimate bearing capacity qu — the maximum gross intensity of loading that soil can support before it fails in shear:

PB2+γDf≯qu

Net ultimate bearing capacity qnu:

PB2≯qnu  (backfilling done),  PB2−γDf≯qnu  (no backfilling)

Net safe bearing capacity qns and gross safe bearing capacity qs:

qns=qnuFOS,  qs=qnuFOS+γDf

Safe bearing pressure qps — the maximum net intensity of loading that can be allowed on soil without the settlement exceeding permissible value. No factor of safety is used while dealing with settlement, because it has already been included in the permissible settlement.

qa-net=min[qns,qps]  — allowable bearing capacity

Modes of Shear Failure

Bearing capacity of soil is calculated on the basis of shear failure criterion. There are three modes of shear failure: (1) general shear failure, (2) local shear failure, (3) punching shear failure.

Ground heaving failure surface I

General shear failure: well-defined failure surface reaching the ground, with visible heaving/bulging on both sides.

slight ground heaving by double tangent method GSF LSF

Local shear failure: considerable compression under footing, only partial development of plastic equilibrium; failure surface does not reach the ground surface, and only slight heaving occurs. No tilting of foundation. Ultimate bearing capacity is not well defined on the load-settlement curve — found via the double tangent method. Occurs in sand for φ<29° and relative density 35–70%; in clays when UCS < 100 kN/m².

Punching shear failure: relatively high compression of soil under the footing, accomplished by shearing in the vertical direction around the edge of footing. No heaving of ground surface, no tilting occurs. Settlement is very high; occurs in soil which is highly compressible, particularly when foundation is located at considerable depth (e.g. pile foundations). Occurs in very loose sand when Dr<35%.

Terzaghi's Bearing Capacity Theory

III II I II III 45−φ/2 Df B

Terzaghi's failure mechanism: Zone I (elastic equilibrium, wedge below the footing, moves with it as part of the foundation), Zone II (radial shear), Zone III (Rankine passive zone).

Terzaghi's assumptions: (1) footing is a strip footing; (2) soil is homogeneous; (3) two-dimensional plane strain conditions prevail; (4) base of footing is rough; (5) Df/B ≤ 1; (6) loading is vertical and symmetrical; (7) general shear failure occurs; (8) ground is horizontal; (9) shearing resistance of soil between the ground surface and the base of footing is neglected; (10) footing is considered as a surface footing with a uniform surcharge of γDf at the base of footing; (11) shear strength of soil is governed by Mohr-Coulomb criteria.

Zone I is prevented from undergoing any lateral movement due to friction and adhesion between the base of footing and soil. It remains in an elastic state and is considered as part of the foundation. At failure, Zone I and the footing press Zone II and Zone III and transform them into a state of plasticity.

qu=cNc+qNq+12BγNγ

Valid for strip footing under general shear failure. q = γDf is the surcharge term.

For φ=0: Nc=5.7, Nq=1, Nγ=0. For clayey soil (φ=0):

qnu=5.7c

Local Shear Failure (φ<29°)

Terzaghi's formula is actually valid for general shear failure. In case of local shear failure we use reduced strength parameters:

cℓ→23c,  tanφℓ→23tanφ,  φℓ→tan−1(23tanφ) qu=(23c)Nc′+qNq′+12BγNγ′

N′c, N′q, N′r = f(φℓ). In exam, it is only when φ<29° that we do modifications for local shear failure. For φ>29°, no modification. For φ ∈ (29°,36°), practically interpolate Nc,Nq,Nγ for both cases and go through the procedure.

Modifications for Footing Shape

Square:

qnu=1.3cNc+q(Nq−1)+0.8(12BγNγ)

Circular (B = diameter):

qnu=1.3cNc+q(Nq−1)+0.6(12BγNγ)

Rectangular:

qnu=(1+0.3BL)cNc+q(Nq−1)+(1−0.2BL)12BγNγ

Effect of Water Table Position

Df B W.T. at Df below footing

Three water-table scenarios, each modifying the surcharge and the failure-zone weight terms.

(1) W.T. above/at the base of footing:

qnu=cNc+q(Nq−1)Rw+(12BγNγ)Rw′

(2) W.T. between the base of footing and depth B below it (rise x above base):

qnu=cNc+γtDf(Nq−1)+12[γtx+γsub(B−x)]Nγ

(3) W.T. above the base of footing (depth y below GL, within Df):

qnu=cNc+(γty+γsub(Df−y))(Nq−1)+12BγsubNγ
In case of sandy soil, when W.T. rises from a great depth up to the ground surface, bearing capacity almost reduces to half: q′nu = (γsub/γt) × qnu (c=0).
Rw, Rw′ 1 1.0 0.5 Dw/Df (or Dw′/B)

Rw and Rw′ are water table correction factors for the 2nd and 3rd terms respectively in Terzaghi's equation, ranging linearly from 0.5 (W.T. at surface) to 1.0 (W.T. at or below the relevant depth):

qnu=cNc+q(Nq−1)Rw+(12BγNγ)Rw′

where q = γtDf and Bγ = Bγt.

Skempton's Bearing Capacity Equation for Clayey Soil

Applicable for saturated clayey soil only, with φu=0 (undrained angle of internal friction). This theory did not neglect the shear strength of soil above foundation level, hence it can be applied to even deeper foundations.

qnu=cNc,  c=UCS2  (undrained cohesion)

Nc = f(Df/B, shape of footing):

Strip:  Nc=5(1+0.2DfB)≤7.5  (Df/B≤2.5, else Nc=7.5) Square/circular:  Nc=6(1+0.2DfB)≤9 Rectangular:  Nc=5(1+0.2DfB)(1+0.2BL)=7.5(1+0.2BL)≤9

B = smaller dimension of the footing.

Worked Example — Terzaghi's Formula, Three Water Table Positions

A 3 m square footing is located in dense sand at depth of 2 m. Determine the ultimate bearing capacity for water at: (a) ground surface, (b) footing level, (c) 1 m below footing level. c=0, φ=35°, Nq=33, Nγ=34. γt=18 kN/m³, γsat=20 kN/m³, γw=10 kN/m³.

Square footing formula (shape-modified, c=0):

qu=qNq+0.4BγNγ

(a) WT at GL: entire soil column submerged, γsub=10:

qu=(20−10)×2×33+0.4×3×10×34
qu=1068 kN/m²

(b) WT at footing level: surcharge term uses γt, weight term uses γsub:

qu=18×2×33+0.4×3×10×34
qu=1596 kN/m²

(c) WT 1 m below footing level: within depth B=3m, 1m is still γt, remaining 2m is γsub:

qu=18×2×33+0.4(1×18+2×10)×34
qu=1704.8 kN/m²

Worked Example — Sizing a Footing (Submerged Soil)

A square footing is located at depth 1.5 m from GL, carries a column load of 150 kN. Soil is submerged, γsub=11 kN/m³, φ=30°. Find the size of footing using Terzaghi's formula. For φ=30°: Nq=10, Nγ=6. FOS=3.

Assuming soil to have been filled back (net intensity = P/B²):

150B2<13(q(Nq−1)+0.4BγNγ) 150B2=13(10×1.5×(10−1)+0.4×B×11×6)
B=1.542 m

Df/B = 1.5/1.542 < 1, OK (satisfies the Df/B ≤ 1 Terzaghi assumption). If Df/B > 1 came out, we would provide Df = B instead.

Larger footing → more settlement For the same intensity of pressure, a bigger foundation leads to more settlement, because the pressure bulb extends to a greater depth, stressing more soil (a larger footing stresses soil to a greater depth, roughly to the 0.1q isobar contour).

Worked Example — Raft Depth via Skempton's Approach

A building is to be supported on raft foundation of dimension 14 m by 21 m. Subsoil is clay with average UCS of 15 kN/m². The pressure on soil due to weight of building and load it carries is 140 kN/m² at the base of raft. Building has provision for basement floor. At what depth should the bottom of raft be placed? Provide FOS of 3 against shear failure. γclay=19 kN/m³, use Skempton's approach.

(PBL−γDf)≤qnuFOS 140−19Df≤cNc3,  c=7.5

Assuming Df/B < 2.5:

140−19Df≤7.5×5(1+0.2Df14)(1+0.21421)3
Df=6.287 m

Df/B = 6.287/14 < 2.5, hence OK.

Worked Example — Strip Footing Width (Skempton, With Backfill)

A strip footing carries 15000 kg/m, founded 1.2 m deep in clay. γsoil=1750 kg/m³, γconc=2500 kg/m³, cu=8500 kg/m², FOS=2. Find the width of footing.

net intensity=[final gross]−[initial gross] =15000+(B×1.2×1×2500)−(1.2×B×1×1750)B×1=15000B+900 15000B+900<cNc2,  c=8500

Assuming Df/B<2.5:

15000B+900<85002×5(1+0.21.2B)
B=0.486 m

Df/B = 1.2/0.486 = 2.47 < 2.5, OK.

Meyerhof's Approach

qnu=cNc(scdcic)+qNq(sqdqiq)+0.5BγNγ(sγdγiγ)

s, d, i are shape, depth and inclination factors.

This approach can be applied for any depth of footing. Failure mechanism is considered the same as that of Terzaghi, but the failure surface is assumed to extend above the foundation level, and shear strength of soil above the base of footing is taken into account.

For φ=0: Nc=5.14, Nq=1, Nγ=0.

Eccentric Loading — Effective Width Method

ex B−2ex (effective width)

To account for eccentricity of loading, the footing dimension becomes concentric to the reduced dimension of footing. Thus instead of B we use (B−2ex), and in place of L we use (L−2ey):

P=qu(L−2ey)(B−2ex)
In case of eccentricity of loading, in case of Terzaghi's formula application, we ensure that the maximum net pressure at the base is less than the net safe bearing capacity.

Plate Load Test

Plate load test is used to calculate: (1) ultimate bearing capacity of soil, (2) allowable bearing pressure corresponding to permissible settlement, (3) settlement of the foundation itself.

sand bags hydraulic jack Bp×Bp load intensity = P/Bp² = qup qup loose sand dense sand settlement double tangent method

Plate load test setup: a rigid plate (Bp×Bp) loaded via a hydraulic jack reacting against sand-bag kentledge, with settlement measured against load intensity.

Sand, square footing:

qufqup=BfBp

Clay:

qufqup=1

For any shape other than square (c=0 sand):

qup=0.4BpγNγ⇒find φ, then Nr, Nq

e.g. Strip:

quf=qNq+12BfγNγ

Settlement Computation

Applicable for sandy soil (since plate load gives immediate settlement); load intensity is same below foundation and plate:

SfSp=[Bf(Bp+0.3)Bp(Bf+0.3)]2,  (Bf,Bp in m)

This approach for calculating settlement is applicable when the testing had been done at the same level at which the foundation is located. However, if the foundation is located at greater depth and testing has been done at a shallower depth, correction to the settlement computed needs to be done:

Sf,corrected=Sf[11+D2Bf]3

D2 = difference in level between the test and the foundation.

In case testing has not been done at the level of footing, then the corrected Sf will be taken as permissible settlement, and from that Sp will be calculated, and this Sp will be used for calculating allowable bearing pressure as done before.

Worked Example — Settlement of a Larger Footing

A plate load test on a sandy soil, with a test plate of size 60×60 cm, undergoes a settlement of 5 mm at a pressure of 12×104 N/m². What will be the expected settlement of a 3 m×3 m footing under the same pressure?

Sf5=[3(0.6+0.3)0.6(3+0.3)]2
Sf=9.298 mm

Worked Example — Ultimate Bearing Capacity of a Strip Footing From a Plate Test

A load test conducted by putting a 60 cm square plate on top of a sandy deposit gave ultimate bearing capacity 60 kN/m². What is the ultimate bearing capacity for a strip footing of 1.2 m width?

qup=0.4BpγNγ 60=0.4×0.6×γNγ⇒γNγ=600.4×0.6 quf=0.5BfγNγ=0.5×1.2×600.4×0.6
quf=150 kN/m²

Demerits of Plate Load Testing

SPT (Standard Penetration Test)

W, h 1.5Bf to 2Bf A 150mm 300mm (Na) B 150mm 75mm (Na)

Split-spoon sampler driven by a 65 kg hammer falling 75 cm; the first 150 mm of penetration is a seating drive (not recorded), and the SPT-N value is the blow count for the next 300 mm.

  1. This test is suitable for sandy soil.
  2. Bore hole is advanced to a depth of the base of footing and SPT-N value is calculated.
  3. Split spoon sampler is allowed to penetrate into the soil by applying an impact load of 65 kg, having a free fall of 75 cm.
  4. Sampler is allowed to penetrate for 150 mm, but the reading is not recorded. The sampler is then allowed to penetrate for the next 300 mm and the number of blows required is noted — this is the SPT-N value for the level from which testing was started.
  5. The next test is carried out at a level of 750 mm below the previous level, and the same procedure is repeated to calculate SPT-N value at various depths.
  6. Following corrections are applied to the observed SPT-N value: (1) overburden correction, (2) dilatancy correction.

1. Overburden Correction

SPT-N value for the foundation should correspond to the average N value corresponding to the mid-depth between the base of footing and the depth 2B. Due to lesser overburden, the sample gets under-compacted, and hence correction is required for overburden.

N1=SPT value corrected for overburden=N[350σ¯+70]

&sigmā = effective stress at the level of test, in kN/m².

2. Dilatancy Correction

Dilatancy correction is applied to the value already corrected for overburden. It is applied only if N1>15, and only below the water table.

N2=15+12(N1−15)  — SPT-N value after dilatancy correction

N1>15 basically represents a dense sand. Thus dilatancy correction is applied for dense sand located below the water table because in case of dense sand, due to impact loading, pore pressure developed is negative, which causes increase in shear strength, resulting in increase in penetration resistance. Thus, observed SPT value would be generally greater and hence needs to be reduced.

NRelative density (%)φ
<4025–32°
4–101527–32°
10–306530–35°
30–508535–40°
>5010038–48°

Allowable Bearing Capacity from SPT — Empirical Formulas

qa-net=min{qms,qps}

Peck-Hanson formula:

qa-net(kN/m²)=0.44Cw⋅N⋅Sa

N = SPT-N value, Sa = permissible settlement (mm). Cw = water table correction factor:

Cw=0.5(1+DwDf+B)≤1

Dw is measured from top of the soil.

IS code formula for raft:

qa-net(kN/m²)=0.88Cw⋅N⋅Sa

Worked Example — Redesigning a Footing for a Smaller Permissible Settlement

A strip footing 8 m wide is designed for total settlement of 40 mm. The safe bearing capacity (shear) was 150 kN/m², and safe allowable soil pressure was 100 kN/m². Due to importance of structure, the footing is now to be redesigned for a total permissible settlement of 25 mm. What will be the new width of footing?

Initially:  qanet=min(150,100)=100 kN/m² load/length=100×8=800 kN/m

Since qanet = 0.44 Cw·N·Sa is proportional to Sa for the same soil (N, Cw unchanged when only the settlement criterion is redesigned):

qanet,finalqanet,initial=2540 qa,net=2540×100=62.5 kN/m²
Bnew=80062.5=12.8 m

Settlement of Foundation

S=Simmediate+Sprimary+Ssecondary

Primary and secondary consolidation can be calculated as discussed earlier (in the consolidation chapter), under the assumption of 1D consolidation. However, in reality consolidation generally will not be 1D. The immediate settlement is calculated using the theory of elasticity:

Simmediate=qnB(1−μ2)ES×If

qn = net foundation pressure, B = width of footing (smaller dim.), μ = Poisson's ratio of soil, ES = modulus of elasticity of soil, If = influence factor depending on shape and rigidity of foundation.

Flexible vs. Rigid Footings

flexible rigid uniform settlement SΎrigidῬ = 0.8 SΎflexibleῬ flexible on clay: uniform contact pressure, dished settlement flexible on sand: higher edge pressure, dished settlement

Srigid = 0.8 Sflexible. In flexible footing, the contact pressure at the interface between footing and soil is uniformly distributed, and the footing itself deforms into a dished shape.

Rigid, clayey Rigid, sandy (E1>E2)

Rigid footing on clay: bowl-shaped (higher) contact pressure toward the centre. Rigid footing on sand: contact pressure peaks toward the edges (since sand near the edge is less confined and stiffer relative to the centre under a rigid plate).

Negative Skin Friction

−ve skin friction unconsolidated soil or loose sand stiff soil

When soil mass of a freshly placed fill or soft compressible deposit moves down relative to the pile, a downward drag is applied on the pile surface — this is called negative skin friction.

It can also develop in loose sand deposits. It also occurs due to lowering of ground water table.

Negative skin friction for a single pile is calculated in the same manner in which the frictional capacity of pile is calculated:

=(Kσ¯avtanδ)Asurface  (sand) =αCuAsurface  (clay)

In case of a group of piles, negative skin friction is calculated as friction on the block + weight of soil in the block (clay):

αCuPL+Abase×Lγ FOS=Ultimate load capacityWorking load+−ve skin friction

Under-Reamed Piles

under-reamed expansive soil d D

Under-reamed piles are provided in case of expansive soil, and also when point-bearing resistance is to be increased. Diameter of bulb = 2 to 3 times diameter of shaft.

Distance/spacing between bulbs=min[1.5×dia. of the bulbs]
P for pullout: πdl → friction area π(D²−d²)/4 → bearing area L2, friction2 = πdL2 L1, friction1 = πdL1

Pullout resistance of an under-reamed pile combines the shaft friction (πdL over each straight segment) and bearing resistance from the bulb's annular face.

Stability of Slope

we assume circular arc Finite slope infinite slope

Slopes classified as finite (limited extent, bounded by a toe and crest) and infinite (extends indefinitely, thin surface layer over a much deeper mass).

In case of finite slope, failure is a rotational failure and the failure surface is part of a circular arc, or a logarithmic spiral. However for analysis purposes, we assume the failure surface to be part of a circle.

(a) Face/slope failure — β high, soil above toe weaker (b) Toe failure — β>53°, most common

Face failure occurs when the slope angle (β) is high and soil above the toe is weaker. Toe failure occurs when there is a homogeneous condition above or below the toe — the most common type, generally when β>53°.

(c) Base failure — β<53° or soft/weak soil below toe

When β<53°, or when soil below the toe is soft and weak, base failure occurs.

In case of infinite slope, failure occurs along a line parallel to the slope.

Stability Analysis of Infinite Slope

1. Dry Cohesionless Soil

bcosβ H W β

Slice of a dry cohesionless infinite slope, width b along the slope (base bcosβ horizontally), depth H.

W=bcosβ×H×1×γ N=Wcosβ=γbHcos2β,  Wsinβ=γbHsinβcosβ FOS=Resisting forceActivating force=(γbHcos2β)tanφγbHcosβsinβ
FOS=tanφtanβ
In case of dry soil condition in infinite slope, failure will occur when slope angle becomes greater than angle of internal friction.

If Seepage Takes Place at a Steady Rate

FOS=[γt(H−h)+γsubh]cosβtanφ[γt(H−h)+γsath]sinβcosβ

h = depth of seepage (measured from the failure plane up to the phreatic surface). When h=H (fully seeped):

FOS=γsubtanφγsattanβ
In case of steady seepage condition, FOS on a plane is almost half as compared to dry condition, since γsub/γsat ≈ 1/2.

Worked Example — FOS on an Infinite Slope With Partial Seepage

Find the FOS on an infinite slope, 10 m thick soil layer at β=30°, with the bottom 8 m saturated (seepage) and top 2 m dry. c=0, φ=35°, γd=16 kN/m³, γsat=20 kN/m³.

FOS=[16×2+10×8]tan35°[16×2+20×8]tan30°
FOS=0.707

Locate the plane on which failure will occur: failure will not occur in the top 2 m, because in case of dry cohesionless soil, failure occurs only when β>φ; here β=30° but φ=35°, hence failure cannot occur in the top 2 m — the critical plane lies within the seeped zone, at depth h ≈ 0.867 m below the top of the seeped region (found by setting FOS=1 for a trial plane within that zone).

Worked Example — Two-Soil Failure Plane Location (Cohesionless)

1m 3m © soil &circle; soil failure plane

Layered slope: 1 m of soil ① over 3 m of soil ②, both cohesionless with different properties.

In these kinds of problems, if we've to locate the failure plane, we'll assume the failure plane once in soil ① and then in soil ②, and calculate the depth by equating FOS=1. The depth so obtained should satisfy the zone in which the failure plane has been assumed.

3. In Case of Clays Under Dry Condition

β h clayey soil

Clayey infinite slope, depth h to the failure plane.

FOS=c+(γthcosβ)tanφγthsinβcosβ

Steady seepage:

FOS=c+(γsathcosβ)tanφγsathsinβcosβ
Note In case of c-φ (clayey) soil, failure will not occur even when φ=β — the cohesion term keeps FOS > 1 at that point. Failure will occur only when β>φ by enough margin to overcome the cohesive resistance too.