SURV-08B Principle of Stadia Method and the Tacheometric Distance Equation
Converted from handwritten notes — SURVEYING 08.pdf, pages 4–5
Doc No.SURV-08B
StatusDraft — Awaiting Review
Converted09-08-2026
Approved—
Principle of stadia method
Let's assume that the line of sight is horizontal and the staff is held vertical.
a, b = stadia hairs, i = stadia interval; F = focus, f = focal length, d = distance from optical centre to instrument axis; u = distance from focus to staff; S = staff intercept.
Horizontal distance between vertical axis of instrument and staff station
Tacheometric distance equation
Using similar triangles a-F-b and A-F-B, together with the lens formula, D is related to the staff intercept S:
Lens formula
Distance equation
where is the multiplying constant (or stadia interval factor), and is the additive constant.
Generally the value of K = 100.
Value of C ranges between 0.25–0.35 m.
If the telescope is fitted with an analytic (anallatic) lens, the value of the additive constant becomes zero, and the tacheometric distance equation reduces to D = KS.