Stadia rod

Stadia rod is a vertical staff which is used when the distance between telescope and staff is so large that graduations become indistinct on an ordinary staff. Beyond 100 m distance, a stadia rod is used.

Subtense bar

Subtense bar is a horizontal bar used for distance measurement.

Methods of tacheometry

  1. Stadia method
  2. Tangential method
  3. Subtense bar method

1) Stadia method

In this method, staff intercept (between upper and lower stadia hairs) and vertical angle θ are measured.

a) Fixed hair method

B A B′ A′ x D

Fixed hair method — stadia interval i (between the fixed upper/lower stadia hairs) stays constant; the staff intercept AB grows to A′B′ as the staff moves away.

In this method, the vertical spacing between the upper stadia hair and lower stadia hair — called the stadia interval — is kept fixed (i). In other words, when the parallactic angle α defined with the help of the stadia wires is kept fixed and the staff intercept is varied — example AB and A′B′ — the method is called the fixed hair method.

b) Movable hair method

In this method the staff intercept is kept fixed, and the stadia interval (i) is varied by using a micrometer screw.

Note As it is inconvenient to measure the stadia interval accurately, the movable hair method is rarely used.

2) Tangential method

S θ₁ θ₂ D

Tangential method — two vertical (pointing) angles θ₁ (lower line of sight) and θ₂ (upper line of sight) are read to the top and bottom of the staff intercept S; no stadia hairs are needed.

In this method, staff intercept is not measured using stadia hairs; two separate pointings and vertical angles θ₁ and θ₂ are taken.

Tangential method — staff intercept S=D(tanθ1−tanθ2)

In this method stadia hairs are not required, hence this method can also be used when a stadia diaphragm is not provided.

3) Subtense bar method

A S B α D plan view

Subtense bar method (plan view) — a horizontal staff of fixed length S is placed horizontally at station B; the horizontal distance D is determined from S and the subtended angle α.

A horizontal staff of fixed length is called a subtense bar. The subtense bar is placed horizontal at station B. The horizontal distance D can be determined from S and α.