Stadia rod is a vertical staff which is used when the distance between telescope and staff is so large that graduations become indistinct on an ordinary staff. Beyond 100 m distance, a stadia rod is used.
Subtense bar is a horizontal bar used for distance measurement.
In this method, staff intercept (between upper and lower stadia hairs) and vertical angle θ are measured.
Fixed hair method — stadia interval i (between the fixed upper/lower stadia hairs) stays constant; the staff intercept AB grows to A′B′ as the staff moves away.
In this method, the vertical spacing between the upper stadia hair and lower stadia hair — called the stadia interval — is kept fixed (i). In other words, when the parallactic angle α defined with the help of the stadia wires is kept fixed and the staff intercept is varied — example AB and A′B′ — the method is called the fixed hair method.
In this method the staff intercept is kept fixed, and the stadia interval (i) is varied by using a micrometer screw.
Tangential method — two vertical (pointing) angles θ₁ (lower line of sight) and θ₂ (upper line of sight) are read to the top and bottom of the staff intercept S; no stadia hairs are needed.
In this method, staff intercept is not measured using stadia hairs; two separate pointings and vertical angles θ₁ and θ₂ are taken.
In this method stadia hairs are not required, hence this method can also be used when a stadia diaphragm is not provided.
Subtense bar method (plan view) — a horizontal staff of fixed length S is placed horizontally at station B; the horizontal distance D is determined from S and the subtended angle α.
A horizontal staff of fixed length is called a subtense bar. The subtense bar is placed horizontal at station B. The horizontal distance D can be determined from S and α.