Transportation Engineering / Surveying

SURV-06E Dumpy and Tilting Levels, Inverted Staff and Permanent Adjustment

Converted from handwritten notes — SURVEYING 05.pdf, pages 19–30

Doc No.SURV-06E
StatusDraft — Awaiting Review
Converted09-08-2026
Approved—

Use of inverted staff

When the point whose elevation is to be found is above the line of sight (for example, the soffit of a beam or slab), the staff is placed inverted with its zero end touching the point under consideration, in order to find the level of that point. Such readings are entered in the book with a negative sign.

soffit of slab A 4 m (inverted staff) B.S. F.S. (−) B.M.

Inverted staff — zero end touches the soffit of the slab at A; the reading is booked as a negative F.S.

H.I.=B.M.+B.S. RL of A=H.I.−(−F.S.)
Worked example — height of T-beam above floor

Find the height of a T-beam above the floor level. RL of the floor is 100 and the staff reading on the floor is 2.055. The reading of staff held upside down against the underside of the beam is 3.655. Also determine the RL of the soffit of the beam.

RL of soffit of beam=B.M.+B.S.−F.S. RL of soffit of beam=100+2.055−(−3.655)=105.710

Height = RL of soffit − RL of floor = 105.710 − 100 = 5.710 m.

Dumpy level and tilting level

Line of sight Vertical axis Dumpy level

Dumpy level — telescope and spindle are cast as one piece; levelling is done using the levelling screws.

In the dumpy level, telescope and spindle are cast as one piece. The levelling is done using the levelling screw. Under proper adjustment, the axis of the bubble tube should be perpendicular to the vertical axis of the instrument.

tilting screw Tilting level

Tilting level — a separate tilting screw allows the line of sight to be levelled independently for each observation.

In the tilting level, the line of sight need not be perpendicular to the vertical axis.

Permanent adjustment of bubble tube

If the line of collimation is parallel to the axis of the bubble tube, the instrument is said to be in permanent adjustment; otherwise there is a collimation error — that is, when the air bubble is in the centre and the line of sight is inclined with the horizontal plane, there will be a collimation error.

Two peg test

A a₁ (+ed₁) B b₁ (+ed₂) e d₁d₂

Setup 1 — instrument midway between A and B (d₁ = d₂).

ΔhAB=(a1−ed1)−(b1−ed2)

If the instrument is set up midway between staff stations A and B, then d₁ = d₂, so:

ΔhAB=a1−b1
A a₂ (+e(d₁+d₂+d₃)) B b₂ (+ed₃) C — instrument d₁ + d₂d₃

Setup 2 — instrument moved outside the line, near C, beyond B.

ΔhAB=(a2−e(d1+d2+d3))−(b2−ed3) ΔhAB=(a2−b2)−e(d1+d2)

Now, equating the two expressions for ΔhAB:

(a1−b1)=(a2−b2)−e(d1+d2) e=(a2−b2)−(a1−b1)d1+d2

The cross hair would be shifted such that the reading on staff station A will be (a₂ − e(d₁+d₂+d₃)).

Worked example — checking adjustment of a tilting level

In order to check the adjustment of a tilting level, the following procedure was followed. Points A, B, C, D were set out on a straight line such that AB = BC = CD = 30 m. The level was set up at B and staff readings were obtained on stations A & C; then the instrument was shifted to station D and staff readings were obtained on stations A & C, as given below. Determine whether or not the instrument is in adjustment; if not, how much is the error?

Instrument stationStaff reading at AStaff reading at C
B1.9261.462
D2.4451.945

From instrument station B:

ΔH=1.926−1.462=0.464

From instrument station D:

ΔH=2.445−1.945=0.500

As the two values of ΔHAC do not match, the instrument is having a collimation error.

e=(a2−b2)−(a1−b1)d1+d2=0.500−0.46460=0.0006

Change required to remove the error, applied at station D looking towards A (distance DA = 90 m):

2.445−0.0006×90=2.391

By using the diaphragm-adjusting screw, the reading on the staff at A (viewed from D) is changed from 2.445 to 2.391 to make the line of sight horizontal.