Transportation Engineering / Surveying
Sensitivity of a level tube is expressed in terms of the angle in seconds subtended at the centre by an arc of 1 division.
Sensitivity angle α′ subtended at the centre of curvature R by one division of length d.
For example, if the divisions are 2 mm apart and the bubble is off centre by 1 division, when the axis of tube is inclined to horizontal by 20″, sensitivity is 20″ per 2 mm.
Radius of the upper surface of the tube is a measure of sensitivity of the level tube. If the radius is quite large, a small movement of bubble tube axis will cause a large displacement of the air bubble, hence the bubble tube will be sensitive.
Let d = 2 mm.
Bubble tube A — for sensitivity of 20″ per 2 mm:
Bubble tube B — for sensitivity of 10″ per 2 mm:
Here bubble tube B is more sensitive than bubble tube A — B only needs 10″ deflection for a 2 mm bubble movement, where A needs 20″ deflection for the same 2 mm movement.
From α′ = d/R — d can be measured, but R cannot be measured directly, so we find it by another way, using the staff intercept observed through the telescope.
Geometry relating bubble-tube tilt α, staff intercept S and horizontal distance D to the instrument.
where S = staff intercept, d = length of 1 division, R = radius of level tube, n = number of divisions moved by the air bubble, D = horizontal distance between staff and the vertical axis of the instrument.
The bubble tube has sensitivity of 20″ per 2 mm. Find the error in staff reading on a vertically held staff at a distance of 200 m, caused by 3 divisions out of centre.
α′ = 20″, d = 2 mm, D = 200 m, n = 3.
S = 0.058 m
The following observations were made to determine the sensitivity of two bubble tubes. Determine which bubble tube is more sensitive. The distance of staff from instrument was 100 m and length of 1 division in both cases is 2 mm.
| Bubble tube | Case | Bubble LHS | Bubble RHS | Staff reading |
|---|---|---|---|---|
| A | i | 13 | 05 | 1.681 |
| A | ii | 08 | 12 | 1.767 |
| B | i | 15 | 03 | 1.635 |
| B | ii | 06 | 14 | 1.788 |
Bubble tube A
α′A ≈ 29.56″
Bubble tube B
α′B ≈ 31.56″
Bubble tube A is more sensitive (smaller angle per division movement).