Transportation Engineering / Surveying

SURV-06C Sensitivity of Level Tube — Theory and Worked Examples

Converted from handwritten notes — SURVEYING 05.pdf, pages 19–30

Doc No.SURV-06C
StatusDraft — Awaiting Review
Converted09-08-2026
Approved—

Sensitivity of level tube

Sensitivity of a level tube is expressed in terms of the angle in seconds subtended at the centre by an arc of 1 division.

d R α′

Sensitivity angle α′ subtended at the centre of curvature R by one division of length d.

α′=dR×(180π×60×60) α′=206265×dR seconds

For example, if the divisions are 2 mm apart and the bubble is off centre by 1 division, when the axis of tube is inclined to horizontal by 20″, sensitivity is 20″ per 2 mm.

Radius of the upper surface of the tube is a measure of sensitivity of the level tube. If the radius is quite large, a small movement of bubble tube axis will cause a large displacement of the air bubble, hence the bubble tube will be sensitive.

Illustration — relating radius to sensitivity

Let d = 2 mm.

Bubble tube A — for sensitivity of 20″ per 2 mm:

R=d×206265α′=2×20626520=20626.5 mm=20.626 m

Bubble tube B — for sensitivity of 10″ per 2 mm:

R=d×206265α′=41.25 m

Here bubble tube B is more sensitive than bubble tube A — B only needs 10″ deflection for a 2 mm bubble movement, where A needs 20″ deflection for the same 2 mm movement.

Increasing sensitivity of a level tube

Note Sensitivity is not a definite quantity unless the length of 1 division is defined. If not specified, the length of 1 division should be taken as 2 mm.

Determination of sensitivity of level tube

From α′ = d/R — d can be measured, but R cannot be measured directly, so we find it by another way, using the staff intercept observed through the telescope.

R α D S α

Geometry relating bubble-tube tilt α, staff intercept S and horizontal distance D to the instrument.

α=ndR,  α=SD α′=dR=SnD

where S = staff intercept, d = length of 1 division, R = radius of level tube, n = number of divisions moved by the air bubble, D = horizontal distance between staff and the vertical axis of the instrument.

Worked example — error in staff reading

The bubble tube has sensitivity of 20″ per 2 mm. Find the error in staff reading on a vertically held staff at a distance of 200 m, caused by 3 divisions out of centre.

α′ = 20″, d = 2 mm, D = 200 m, n = 3.

S=α′nD206265=20″×3×200206265

S = 0.058 m

Worked example — comparing sensitivity of two bubble tubes

The following observations were made to determine the sensitivity of two bubble tubes. Determine which bubble tube is more sensitive. The distance of staff from instrument was 100 m and length of 1 division in both cases is 2 mm.

Bubble tubeCaseBubble LHSBubble RHSStaff reading
Ai13051.681
Aii08121.767
Bi15031.635
Bii06141.788
Note Length of bubble can vary under the action of gravity or with temperature change; it will be sufficient to measure the displacement of one end of the air bubble only to determine the total displacement on account of tilting of the bubble tube axis. But if the length of the bubble tube changes, we have to take initial and final reading of both left and right hand ends of the bubble to determine the displacement of the bubble on account of tilting of the bubble tube axis.

Bubble tube A

n=(13−5)+(12−8)2=6 α′A=(1.767−1.681)6×100×206265

α′A ≈ 29.56″

Bubble tube B

n=(15−3)+(14−6)2=10 α′B=(1.788−1.635)10×100×206265

α′B ≈ 31.56″

Bubble tube A is more sensitive (smaller angle per division movement).