Different methods of levelling
1. Direct / Spirit level
It is the most common method of levelling. A spirit level fixed to the telescope of a levelling instrument is used to make the line of sight horizontal. Vertical distances are measured with respect to the horizontal line of sight.
Trigonometric levelling — the difference of elevation D tanα is derived indirectly from horizontal distance D and vertical angle α.
2. Trigonometric levelling
This is an indirect method of levelling in which the difference of elevation is determined indirectly from the horizontal distance and vertical angle.
3. Barometric levelling
Another type of indirect levelling in which elevations are determined indirectly from the change in atmospheric pressure. Atmospheric pressure decreases with the increase in elevation. Altimeter, aneroid barometer and mercury barometer, etc., are used for determining change in atmospheric pressure — the mercury barometer is fragile, i.e. easily breakable. Altimeters are used for determining the altitude of an aeroplane.
4. Hypsometric levelling
In this process of levelling, elevation is determined by observing the temperature at which the boiling of water starts. As altitude increases, the boiling point of water decreases.
Direct levelling — types
1. Simple levelling
In this method, only one setting of instrument is done. It is done to determine relative elevations of two points which are visible from a single point.
2. Differential levelling / Compound levelling
It is a method of levelling in which more than one setting of instrument is required for determining elevation between two or more points. It is used when — (a) two points are at a large distance, (b) difference of elevation between two points is large, (c) some obstacle is in between two points.
3. Check levelling
It is a type of differential levelling done for the purpose of checking of elevations which have already been observed. Generally the check levelling is done at the end of each day's work, from the last station back to the starting station, for checking that day's work.
Check levelling run from the day's last station (T.B.M.) back to the starting bench mark.
4. Fly levelling
It is a type of differential levelling used for determination of approximate elevations of different points. Distance between stations are kept as long as possible. It is done where rapidity and low precision is required. Only back sight and fore sight are taken.
5. Profile levelling / Longitudinal levelling
It is a type of differential levelling done for the purpose of determining elevation of ground surface along a fixed line. The fixed line is generally the centreline of a proposed route such as road, railway, canal, etc. It is also used for fixing the gradient along the centreline.
Profile levelling along the centreline with cross-sectional levelling taken perpendicular to it at each chainage.
6. Cross-sectional levelling
It is a type of differential levelling done to determine the difference of elevation of ground surface along the lines perpendicular to the centreline. Generally profile levelling and cross-sectional levelling are done simultaneously. It is used for estimation of earthwork.
7. Reciprocal levelling
This is a special kind of levelling. It is used to determine the difference of elevation between two points which are situated quite a large distance apart, and it is not possible to set up the instrument in between these two points — for example, if two points are on opposite sides of a deep valley, or on the opposite bank of a river.
Optical defects in lens of telescope
The common defects are (1) chromatic aberration and (2) spherical aberration.
Chromatic aberration
Chromatic aberration occurs in the telescope due to dispersion of white light. White light splits into component colours which results in formation of a rainbow near the image, due to which focusing becomes difficult. This defect can be removed by using a combination of two lenses — a concave flint-glass lens (45–65% PbO) and a convex crown-glass lens, joined together by a chemical called Canada Balsam.
Achromatic combination — concave flint-glass lens cemented to convex crown-glass lens with Canada Balsam.
Spherical aberration
Spherical aberration occurs due to the irregularities present in the spherical surface of the lens. This defect can also be corrected by using the same combination of lenses as discussed above.
Aplanation → absence of spherical aberration.
Achromatism → absence of chromatic aberration.
Level tube
Level tube (bubble tube) — the longitudinal line tangent to the inner surface at the mid-point is the axis of the level tube.
Level tube / bubble tube is an essential part of most surveying instruments as the line of direction of gravity is determined either by means of a plumb bob or a level tube.
The level tube is a glass tube sealed at both ends, the inside of which is ground to a circular longitudinal curve, and nearly filled with a sensitive liquid such as alcohol or ether, leaving enough space for a bubble.
The liquid should be — (a) stable and non-freezing at ordinary temperature, (b) of low viscosity. Previously alcohol, ether and chloroform were commonly used, but nowadays purified synthetic alcohol is used.
Cross-section of the level tube is uniform.
Upper surface of the tube has graduations which are symmetrical about the centre and equally spaced.
When the bubble is at the centre, the axis of the level tube is horizontal, i.e. the bubble tube is perpendicular to the line of gravity.
On account of the action of gravity on the liquid, the air bubble moves towards the highest point.