Structural Engineering / Structural Analysis / Part 3 of 13
Stability of a structure is classified as (a) external stability, (b) internal stability. If a body is sufficiently constrained by external reactions such that rigid body motion does not take place, the structure is called externally stable.
Triangular frame with pin (left) and roller with a horizontal reaction (right) — all three reaction lines pass through the same point, so the frame can still rotate about it. Unstable.
Left: pin+roller = only 2 reactions — unstable (< 3 reactions). Right: three rollers — unstable (parallel reactions).
Triangular truss on pin + roller with an applied horizontal load — stable, because the 3 support reactions are non-concurrent.
If one part of the structure moves appreciably with respect to another, the structure is said to be unstable internally.
Two hinges close together in the same span — the segment between them can rotate freely as a mechanism. Unstable.
A pin support placed under the first hinge restores rigidity there (it "generates the moment" a free hinge otherwise lacks) — leaving only one true internal hinge. Stable.
Braced frame with the diagonal present — stable, Dsi = 0.
Same frame without the diagonal member, one cut through the top beam — unstable by the missing diagonal, but the calculation itself yields Dsi = −1 (a negative Dsi is informative, not conclusive on its own).
(with diagonal present, C=3, stable)
(without diagonal, one more cut, C=4)
2D trusses, m = members, r = support reactions, j = joints:
If, on a triangular framework, successive addition of two members and one joint leads to the complete geometry of the truss, then the truss is called a simple truss, and the simple truss is internally determinate and stable.
Starting from a base triangle, each successive joint is added with two new members — the classic "simple truss" construction rule.
In a simple truss, if an additional member is added as a double-diagonal panel member, then Dsi = number of double-diagonal panels.
Fink-type roof truss with a double-diagonal panel (highlighted) in the middle bay.
Dse = (4−3) = 1, Dsi = 2 (the double-diagonal panel).
m = 12, r = 4, j = 7. Two double-diagonal panels give Dsi = 2 — wait, worked as Dsi=1, Dse=1 in the source (only one full double-diagonal counted independently); Ds = Dsi+Dse = 2.
Triangular tower truss with a double-diagonal cross-brace panel (highlighted).
For a space truss (3D):
In the displacement method of analysis (stiffness method), joint displacements are taken as unknown. The number of unknown joint displacements is called the degree of kinematic indeterminacy, or degree of freedom. For obtaining the value of unknown joint displacements, we need to write equilibrium equations — the number of equilibrium equations required is equal to the degree of kinematic indeterminacy.
| Type of joint | Total possible DOF | Formula |
|---|---|---|
| Rigid-jointed plane frame | Δx, Δy, θz — 3 nos | DK = 3j − r |
| Rigid-jointed space frame | Δx, Δy, Δz, θx, θy, θz — 6 nos | DK = 6j − r |
| Pin-jointed plane truss | Δx, Δy — 2 nos | DK = 2j − r |
| Pin-jointed space truss | Δx, Δy, Δz — 3 nos | DK = 3j − r |
j → no. of joints. r → no. of support reactions.
Two-storey, two-bay frame: joint 1 fixed (r=3), joint 8 roller (r=1), joint 9 pin (r=2).
Unknowns (before considering inextensibility): Δx₂, Δx₃, Δx₄ (marked Δ′), Δx₅, Δx₆, Δx₇ (axial member elongations struck through where inextensibility removes them), Δx₈, θ₈, and θ₂ through θ₇.
If inextensibility is considered: Δx₂ = Δx₇ = Δx₆ = Δ (one group of 3), and Δx₃ = Δx₄ = Δx₅ = Δ′ (another group of 3) — giving DK = 21 − m′, where m′ = number of inextensible members reducing independent unknowns.
10 = no. of inextensible members.
If a rigid-jointed plane frame has an internal hinge or joint hinge, additional degrees of freedom are created.
A member/internal hinge at the beam midspan creates 4 additional DOF: Δx, Δy, θ₁ (rotation just left of the hinge), θ₂ (rotation just right of it).
Release-temperature (rocker-roller) support — additional DOF = 4: Δx₁, Δx₂, Δy, θ.
A hinge-plus-roller support (releases both moment and horizontal restraint) — additional DOF = 5: θ₁, θ₂, Δx₁, Δx₂, Δy.
Release-shear (double-roller-in-a-slot) support — additional DOF = 4: Δx, θ, Δy₁, Δy₂.
Fixed-fixed portal, member hinge at mid-beam (joint 3).
Unknowns: Δx₂, Δy₂, θ₂, θ₃₂, θ₃₄, Δx₃, Δy₃, θ₄. DK = 10 (without considering inextensibility).
If inextensibility is considered: Δy₂=0, Δy₄=0, Δx₂=Δx₃=Δx₄ — DOF reduces by 4.
Fixed-fixed portal frame, no internal hinges.
Unknowns: Δx₂, Δy₂, θ₂₁, θ₃ — DK = 7 without inextensibility. If inextensibility considered, DOF reduced by 3 (giving DK = 4).
Fixed base at left, pin base at right, joint hinge in the roof at mid-span.
Unknowns: Δx₂, Δx₃₂, Δx₄, Δy₂, Δx₃₄, Δy₄, θ₂, Δy₃, θ₄, θ₃ — DK = 11 without inextensibility.
If inextensibility is considered: Δx₂=0, Δy₄=0, Δx₂=Δx₃₂, Δx₃₄=Δx₄ — DK reduces by 4.
Fixed-fixed portal, roller-type joint hinge in the roof.
Unknowns: Δx₂, Δx₃₂, Δx₄, Δy₂, Δx₃₄, Δy₄, θ₂ — DK = 11 without inextensibility.
If inextensibility is considered: Δx₂=0, Δx₄=0, Δx₂=Δx₃₂, Δx₄=Δx₃₄ — DK reduces by 4.
Fixed base at 1, pin base at 8; joint hinge inside the top beam.
DK = 22 (before inextensibility). Considering inextensibility: Δy₂=0, Δy₃=Δy₄, Δy₆=Δy₇=0 (reduces by 4); Δx₂=Δx₃=Δx₇=0, Δx₄=Δx₅=Δx₆ (reduces by 5) — DK reduces by 9.
Two-storey frame, single beam continuous across, lower tier storey slightly stepped.
Considering inextensibility: Δy₂=0, Δy₃=0, Δy₆=0, Δy₇=0 (reduces by 4); Δx₂=Δx₇, Δx₃=Δx₄=Δx₅=Δx₆ (reduces by 4) — DK reduces by 8.
Fixed base, two roller supports, with the roof overhanging past the last support — the overhang's free end is still treated as a joint.
Pin support, internal (member) hinge at midspan, roller support, fixed support at the right end.
Unknowns: θ₁, θ₂₁, θ₃, θ₂₃, Δx₂, Δy₂, Δx₃ — DK = 7.
If inextensibility considered: Δx₂=0=Δx₃ — DK reduces by 2.
Gable frame with a ridge joint (3) between two rafters.
Unknowns: θ₂, θ₃, θ₄, Δx₂, Δx₃, Δx₄, Δy₂, Δy₃, Δy₄ — DK = 9.
If inextensibility is considered: Δy₂=0, Δy₄=0 — leaving Δx₂, Δx₃, Δy₃, Δx₄, but only two of these four are independent, since two inextensibility conditions apply (members 2–3 and 3–4).
Frame with sloping legs at pin bases A and D — sway displacement resolves into components along each leg's axis and perpendicular to it, coupled through geometry at joints B and C.
θB, θC, Δ (the single independent sway displacement) are the independent displacements when considering inextensibility.
If inextensibility not considered:
Horizontal grid with fixed outer ends, subjected to vertical (out-of-plane) loading only.
This structure would be treated as a 2D rigid frame — at any joint we have to consider three displacements. They are Δy, θx and θz.
Six-member grid with all outer ends fixed — DK = 12 at the central joint alone, plus the given 5 additional independent DOF at a second junction.