Structural Engineering / Plastic Analysis / Part 2 of 3
Inverted T-section: flange 120 × 20 on top, web 20 wide, overall depth 200 mm.
Find x̄ (centroid) from bottom: flange area 180×20 = ... using centroid of each rectangle about the base.
A = 6000 mm², yΎmaxῬ = 130 mm (larger distance to extreme fibre, from the bottom).
Locate the equal-area axis: total area = 6000 mm², so each half is 3000 mm². Within the 20 mm-wide web, 3000 = 20·x ⇒ x = 150 mm from the bottom (i.e. 150 mm depth of web + part of flange is below; here the equal-area axis lies 150 mm up the web, well within the web since web height is 180 mm).
CG of the area above the equal-area axis (flange 120×20 + web strip 30×20, i.e. from 150 to 180 mm depth):
CG of the area below the equal-area axis (web strip, 150 mm deep):
Following conditions must be satisfied in plastic analysis:
Partial collapse (mechanism forms in only part of the structure) vs. complete collapse (whole structure becomes a mechanism).
If the above three conditions are satisfied, a unique lowest value of collapse load will be obtained. Based on these conditions we have two methods of analysis:
Of the various possible mechanisms, the correct mechanism is the one for which the loading is minimum (P ≥ Pu). This theorem satisfies the equilibrium and mechanism conditions.
The load determined on the basis of any collapse BMD in which the bending moment at any section is less than the plastic moment will be less than or equal to the actual collapse load (P ≤ Pu). This theorem satisfies the equilibrium and yield conditions.
Lower bound / static method: an assumed collapse BMD (redundant moment chosen freely) that nowhere exceeds Mp gives a safe (≤) estimate of the collapse load.
Static method: select the redundant moment at the fixed support; free BMD (simply-supported) plus redundant BMD combine so the mechanism forms at collapse.
A combined BMD is drawn such that a mechanism is formed — two hinges: one at the fixed support (moment Mp) and one under the load (moment Mp). By similar triangles, the redundant moment at midspan is Mp/2:
Verified via equilibrium: taking moments of the free body about the hinge under the load (BM = Mp there too):
Locate possible hinge places, Ds = 1 for this propped cantilever. Assume the mechanism with hinges at the fixed support and under the load; equate external and internal virtual work (elastic deformations neglected):
Wait — checking the moment directions at the propped-cantilever's central hinge (as in the source): the two adjacent segments both rotate by θ, giving 3Mpθ of internal work net:
Propped cantilever under UDL — the in-span hinge does not form at x = l/2, but where the shear force is zero.
Equilibrium of each segment about its far end (moment at both the fixed support and the in-span hinge = Mp):
Eliminating Mp:
Substituting x = 0.414l into Mp = wx²/2 gives the collapse load:
Assuming the hinge at distance x from the fixed end (with (l−x) on the propped side), and rotations related by :
Minimising w (dw/dx = 0) confirms x = 0.414l and gives w = 11.565 Mp/l² (matches the static-method result up to rounding).
Propped cantilever AB with overhang BC — value of 'a' sought for simultaneous collapse of the span AB and the overhang BC.
For simultaneous collapse of span AB and overhang BC (each hits Mp at the same load level):
Fixed-fixed beam, working UDL 100 kN/m, load factor 1.75. Find Mp.
100 kN/m is the working load; collapse load = load factor × working load = 1.75 × 100 = 175 kN/m.
This result is valid only when all hinges required for collapse form simultaneously, i.e. when there is no redistribution of moment.
Two hinges required (support + midspan, if hinges form at the same Mp for both regions of the beam). By symmetry, taking x from the left support and (3−x) as the remaining half-span distance to the SF=0 point:
Solving gives x = 2.25 m, and:
Alternative check via the reaction: RA = 175×3×4.5/6 = 393.75 kN; SF = 0 at x = 393.75/175 = 2.25 m. The shaded area under the free-BMD triangle up to x = 2.25 m equals 2Mp:
Fixed beam under two unequal third-point loads 2W and W, Mp constant. Find W at collapse.
Reactions and free BM values under each load:
Since Mp is constant throughout, the maximum free-BMD ordinate equals 2Mp:
Continuous beam ABCDE, Mp constant throughout — failure of individual spans is considered independently.
Continuous beam ABCD under given collapse loads, each span with uniform section — determine the required Mp for each span so all spans collapse under the shown system.
Assume the middle span BC to be the lightest (MpBC < MpAB, MpBC < MpCD), so span BC governs the c/s adopted throughout adjoining spans' redundant-moment relations.
With the redundant moment at B already fixed at MpBC = 250 kN·m (continuity), and the peak of the combined BMD at the hinge under the load:
Solving: x = 0.4375ℓ = 2.1875 m,
| Span | Mp required |
|---|---|
| AB | 583.33 kN·m |
| BC | 250 kN·m |
| CD | 382.63 kN·m |
The c/s provided in each span corresponds to the respective values of Mp — that is, each span is designed with a different section, sized to its own required Mp.
Fixed-fixed beam AC with a step change in section at B (midspan): AB has capacity 2Mp, BC has capacity Mp. Point load W at L/3 from A. Find collapse load W.
Two possible collapse mechanisms considered — of the two, the correct mechanism is the one giving the minimum collapse load.
Both mechanisms give the same collapse load here; of the two possible mechanisms, the correct one is the one for which the loading is minimum.
Free BMD ordinate below the point load = 2WL/9; ordinate at midspan (L/2) = WL/6. With redundant moments 2Mp at A and Mp at C:
This gives W = 16.5 Mp/L for one condition and W = 15Mp/L for the other (governing); hence collapse load = 15Mp/L, confirming mechanism 1 as correct.
Two-span beam ABC on three simple supports, point loads 200 kN (span AB) and 100 kN (span BC). Mp constant. Three mechanisms are checked; the largest Mp value obtained governs the design.
Mp will be calculated from three possible mechanisms and the largest value adopted, since the section must be strong enough to resist collapse under any of them.